SearcharxivSearch

arXiv subjects

F. Spinella

Publications and source records attributed to F. Spinella.

At least 19 recordsLinked to original sources

HIKE, High Intensity Kaon Experiments at the CERN SPS

A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the Standard Model. The experimental programme is based on a staged approach involving experiments with charged and neutral kaon beams, as well as operation in beam-dump mode. The various phases will rely on a common infrastructure and set of detectors.

hep-ex

An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

physics.ins-det

Mu2e-II: Muon to electron conversion with PIP-II

An observation of Charged Lepton Flavor Violation (CLFV) would be unambiguous evidence for physics beyond the Standard Model. The Mu2e and COMET experiments, under construction, are designed to push the sensitivity to CLFV in the mu to e conversion process to unprecedented levels. Whether conversion is observed or not, there is a strong case to be made for further improving sensitivity, or for examining the process on additional target materials. Mu2e-II is a proposed upgrade to Mu2e, with at least an additional order of magnitude in sensitivity to the conversion rate over Mu2e. The approach and challenges for this proposal are summarized. Mu2e-II may be regarded as the next logical step in a continued high-intensity muon program at FNAL.

hep-ex

A New Charged Lepton Flavor Violation Program at Fermilab

The muon has played a central role in establishing the Standard Model of particle physics, and continues to provide valuable information about the nature of new physics. A new complex at Fermilab, the Advanced Muon Facility, would provide the world's most intense positive and negative muon beams by exploiting the full potential of PIP-II and the Booster upgrade. This facility would enable a broad muon physics program, including studies of charged lepton flavor violation, muonium-antimuonium transitions, a storage ring muon EDM experiment, and muon spin rotation experiments. This document describes a staged realization of this complex, together with a series of next-generation experiments to search for charged lepton flavor violation.

hep-ex

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: Strip, a radiometer-based telescope on the ground in Tenerife, and SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2021/22 for SWIPE, with a flight duration up to 15 days, and in Summer 2021 with two years observations for Strip. We describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact into performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE can reach a sensitivity in tensor-to-scalar ratio of $σ_r<0.01$, and improve constrains on other cosmological parameters.

astro-ph.IM

Trigger-DAQ and Slow Controls Systems in the Mu2e Experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far. Mu2e's Trigger and Data Acquisition System (TDAQ) uses otsdaq as its solution. Developed at Fermilab, otsdaq uses the artdaq DAQ framework and art analysis framework, under the-hood, for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability, while providing a multi-user, web-based, interface accessible through the Chrome or Firefox web browser. The detector Read Out Controller (ROC), from the tracker and calorimeter, stream out zero-suppressed data continuously to the Data Transfer Controller (DTC). Data is then read over the PCIe bus to a software filter algorithm that selects events which are finally combined with the data flux that comes froma Cosmic Ray Ve to System (CRV). A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) Open Source Platform. The DCS System has also been itegrated into otsdaq. The installation of the TDAQ and the DCS systems in the Mu2e building is planned for 2021-2022, and a prototype has been built at Fermilab's Feynman Computing Center. We report here on the developments and achievements of the integration of Mu2e's DCS system into the online otsdaq software.

physics.ins-det

Progress report on the Large Scale Polarization Explorer

The Large Scale Polarization Explorer (LSPE) is a cosmology program for the measurement of large scale curl-like features (B-modes) in the polarization of the Cosmic Microwave Background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by covering a large portion of the northern microwave sky. LSPE/STRIP is a coherent array of receivers planned to be operated from the Teide Observatory in Tenerife, for the control and characterization of the low-frequency polarized signals of galactic origin; LSPE/SWIPE is a balloon-borne bolometric polarimeter based on 330 large throughput multi-moded detectors, designed to measure the CMB polarization at 150 GHz and to monitor the polarized emission by galactic dust above 200 GHz. The combined performance and the expected level of systematics mitigation will allow LSPE to constrain primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report the status of the STRIP pre-commissioning phase and the progress in the characterization of the key subsystems of the SWIPE payload (namely the cryogenic polarization modulation unit and the multi-moded TES pixels) prior to receiver integration.

astro-ph.IM

Mu2e calorimeter readout system

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.

physics.ins-det

The integrated low-level trigger and readout system of the CERN NA62 experiment

The integrated low-level trigger and data acquisition (TDAQ) system of the NA62 experiment at CERN is described. The requirements of a large and fast data reduction in a high-rate environment for a medium-scale, distributed ensemble of many different sub-detectors led to the concept of a fully digital integrated system with good scaling capabilities. The NA62 TDAQ system is rather unique in allowing full flexibility on this scale, allowing in principle any information available from the detector to be used for triggering. The design concept, implementation and performances from the first years of running are illustrated.

physics.ins-det

The Mu2e calorimeter: quality assurance of production crystals and SiPMs

The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.

physics.ins-det

Design, status and perspective of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $μ$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.

physics.ins-det

The Mu2e undoped CsI crystal calorimeter

The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

physics.ins-det

Quality Assurance on Un-Doped CsI Crystals for the Mu2e Experiment

The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.

physics.ins-det

The Mu2e Calorimeter Final Technical Design Report

Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.

physics.ins-det

Design and status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.

physics.ins-det

The Mu2e crystal calorimeter

The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $μ^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021. The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates %\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{μe} = \frac{μ^- + A(Z,N) \to e^- +A(Z,N)}{μ^- + A(Z,N) \to ν_μ ^- +A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for $μ\to e γ$ decay at MEG as well as the direct searches for new physics at the LHC. The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons ($\sim 10^{10} μ/$ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.

physics.ins-det

Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers

The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on this first batch of photosensors: the breakdown voltage, the gain, the quenching time, the dark current and the Photon Detection Efficiency (PDE) have been determined for each monolithic cell of each SiPMs array. One sample for each vendor has been exposed to a neutron fluency up to $\sim$8.5~$\times$~10$^{11}$ 1 MeV (Si) eq. n/cm$^{2}$ and a linear increase of the dark current up to tens of mA has been observed. Others 5 samples for each vendor have undergone an accelerated aging in order to verify a Mean Time To Failure (MTTF) higher than $\sim$10$^{6}$ hours.

physics.ins-det

Quality Assurance on a custom SiPMs array for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.

physics.ins-det