SearcharxivSearch

arXiv subjects

F. Tommasino

Publications and source records attributed to F. Tommasino.

6 recordsLinked to original sources

Toward High-Resolution Detection of Target Fragmentation: TEA-Sensitized NIT for Proton Therapy Applications

Nano Imaging Trackers (NIT) are fine-grained nuclear emulsions capable of tracking charged particles with sub-micrometric spatial resolution. The DAMON (Direct Measurement of Target Fragmentation) experiment recently employed NIT to detect target-fragmentation events relevant to proton therapy in direct kinematics. These measurements showed that the small crystal size, while providing high spatial resolution, limits the reconstruction efficiency for primary proton tracks and high-energy secondary protons. This work reports an enhancement of NIT sensitivity achieved through alternative chemical sensitization methods, namely gold-plus-sulfur (Au-S) and triethanolamine (TEA), together with the use of the GR-1 developer. The detector response was evaluated with gamma-ray, carbon-ion and proton exposures, including clinically relevant proton energies.

physics.ins-det

Angular differential and elemental fragmentation cross sections of a $400\,\text{MeV/nucleon}$ $^{16}\text{O}$ beam on a graphite target with the FOOT experiment

This paper presents the measurements of the angular differential cross sections for the forward production of He, Li, Be, B, C and N nuclei in the fragmentation process of a 400$\text{MeV/nucleon}$ $^{16}\text{O}$ beam interacting with a graphite target. Due to the limited data available in this energy regime, these measurements of nuclear fragmentation cross sections are relevant to improve nuclear interaction models for Particle Therapy and space radioprotection applications. The data analyzed in this paper were collected during a measurement campaign carried out at the GSI Helmholtz Center for Heavy Ion Research facility in Darmstadt (Germany) by the FOOT collaboration. The results are compared with similar results found in the literature and with a previous FOOT measurement of the same process, using the same setup, from a previous pilot run performed at GSI. The pilot run data, however, had limited statistics and only allowed for the measurement of elemental fragmentation cross sections integrated in the setup acceptance. This data set, with statistics more than 100 times larger compared to the data collected in the previous run, enabled the measurement of angular differential cross sections, fully exploiting the granularity of the FOOT $Δ\text{E}$-TOF system. Furthermore, a better comprehension of the FOOT apparatus allowed to improve the analysis techniques, leading to a reduction in the final systematic uncertainties.

nucl-ex

Cross Section Measurements of Large Angle Fragments Production in the Interaction of Carbon Ion Beams with Thin Targets

The fragmentation cross sections of carbon ion beams with kinetic energies of $115 - 353~\text{MeV/u}$ impinging on thin targets of graphite (C), polyvinyl-toluene (C$_9$H$_{10}$) and PMMA (C$_2$O$_5$H$_8$) have been measured at 90$^{\text{o}}$ and 60$^{\text{o}}$ at the CNAO particle therapy center (Pavia, Italy). The presented measurements are a complete reanalysis by the FOOT collaboration of already published elemental cross section on composite targets, in order to refine the analysis, improve the systematic uncertainties and show the comparison with the FLUKA Monte Carlo code calculations. In this work, the kinetic energy at production of measured fragments has been completely redefined, together with the efficiencies computation. The new analysis strategy has been successfully validated against the Monte Carlo cross sections. Two detection arms were positioned at two different angles to perform the measurement at 90$^{\text{o}}$ and 60$^{\text{o}}$. The fragment species have been identified in charge (Z$_{id}$ = H) and mass (M$_{id}$ = $^1$H, $^2$H, $^3$H) combining the information of the deposited energy in thin plastic scintillators, of the deposited energy in a thick LYSO crystal and of the fragments Time of Flight (ToF) measurement. The ToF was also used to compute the fragments measured kinetic energy. The cross sections are presented as a function of the fragments kinetic energy at production thanks to an unfolding technique applied to the data.

nucl-ex

Linking microdosimetric measurements to biological effectiveness: a review of theoretical aspects of MKM and other models

Different qualities of radiation are known to cause different biological effects at the same absorbed dose. Enhancements of the biological effectiveness are a direct consequence of the energy deposition clustering at the scales of DNA molecule and cell nucleus whilst absorbed dose is a macroscopic averaged quantity which does not take into account heterogeneities at the nanometer and micrometer scales. Microdosimetry aims to measure radiation quality at cellular or sub-cellular levels trying to increase the understanding of radiation damage mechanisms and effects. A review of the major models based on experimental microdosimetry, with an emphasis on the Microdosimetric Kinetic Model (MKM) will be presented in this work, enlightening the advantages of each one in terms of accuracy, initial assumptions and agreement with experimental data. The MKM has been used to predict different kinds of radiobiological quantities such as the Relative Biological Effects for cell inactivation or the Oxygen Enhancement Ratio (OER). Recent developments of the MKM will be also presented, including new non-Poissonian correction approaches for high linear energy transfer (LET) radiation, the inclusion of partial repair effects for fractionation studies and the extension of the model to account for non-targeted effects. We will also explore developments for improving the models by including track structure and the spatial damage correlation information by using the full fluence spectrum and, briefly, nanodosimetric quantities to better account for the energy-deposition fluctuations at the intra- and inter-cellular level.

physics.med-ph

A summary on an investigation of GAGG:Ce afterglow emission in the context of future space applications within the HERMES nanosatellite mission

GAGG:Ce (Cerium-doped Gadolinium Aluminium Gallium Garnet) is a promising new scintillator crystal. A wide array of interesting features, such as high light output, fast decay times, almost non-existent intrinsic background and robustness, make GAGG:Ce an interesting candidate as a component of new space-based gamma-ray detectors. As a consequence of its novelty, literature on GAGG:Ce is still lacking on points crucial to its applicability in space missions. In particular, GAGG:Ce is characterized by unusually high and long-lasting delayed luminescence. This afterglow emission can be stimulated by the interactions between the scintillator and the particles of the near-Earth radiation environment. By contributing to the noise, it will impact the detector performance to some degree. In this manuscript we summarize the results of an irradiation campaign of GAGG:Ce crystals with protons, conducted in the framework of the HERMES-TP/SP (High Energy Rapid Modular Ensemble of Satellites - Technological and Scientific Pathfinder) mission. A GAGG:Ce sample was irradiated with 70 MeV protons, at doses equivalent to those expected in equatorial and sun-synchronous Low-Earth orbits over orbital periods spanning 6 months to 10 years, time lapses representative of satellite lifetimes. We introduce a new model of GAGG:Ce afterglow emission able to fully capture our observations. Results are applied to the HERMES-TP/SP scenario, aiming at an upper-bound estimate of the detector performance degradation due to the afterglow emission expected from the interaction between the scintillator and the near-Earth radiation environment.

astro-ph.IM

A novel hybrid microdosimeter for radiation field characterization based on TEPC detector and LGADs tracker: a feasibility study

In microdosimetry, lineal energies y are calculated from energy depositions $ε$ inside the microdosimeter divided by the mean chord length, whose value is based on geometrical assumptions on both the detector and the radiation field. This work presents an innovative two-stages hybrid detector (HDM: hybrid detector for microdosimetry) composed by a Tissue Equivalent Proportional Counter (TEPC) and a silicon tracker made of 4 Low Gain Avalanche Diode (LGAD). This design provides a direct measurement of energy deposition in tissue as well as particles tracking with a submillimeter spatial resolution. The data collected by the detector allow to obtain the real track length traversed by each particle in the TEPC and thus estimates microdosimetry spectra without the mean chord length approximation. Using Geant4 toolkit, we investigated HDM performances in terms of detection and tracking efficiencies when placed in water and exposed to protons and carbon ions in the therapeutic energy range. The results indicate that the mean chord length approximation underestimate particles with short track, which often are characterized by a high energy deposition and thus can be biologically relevant. Tracking efficiency depends on the LGAD configurations: 34 strips sensors have a higher detection efficiency but lower spatial resolution than 71 strips sensors. Further studies will be performed both with Geant4 and experimentally to optimize the detector design on the bases of the radiation field of interest. The main purpose of HDM is to improve the assessment of the radiation biological effectiveness via microdosimetric measurements, exploiting a new definition of the lineal energy ($y_{T}$), defined as the energy deposition $ε$ inside the microdosimeter divided by the real track length of the particle.

physics.ins-det