Searcharxiv⌕ Search

arXiv subjects

F. Ya. Khalili

Publications and source records attributed to F. Ya. Khalili.

29 records · Page 2Linked to original sources

Quantum variational measurement in the next generation gravitational-wave detectors

A relatively simple method of overcoming the Standard Quantum Limit in the next-generation Advanced LIGO gravitational wave detector is considered. It is based on the quantum variational measurement with a single short (a few tens of meters) filter cavity. Estimates show that this method allows to reduce the radiation pressure noise at low frequencies ($<100 \mathrm{Hz}$) to the level comparable with or smaller than the low-frequency noises of non-quantum origin (mirrors suspension noise, mirrors internal thermal noise, and gravity gradients fluctuations).

gr-qc↗

Quantum variational measurement and the "optical lever" intracavity topology of gravitational-wave detectors

The intracavity topologies of laser gravitational-wave detectors are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). The most challenging element of the intracavity topologies is the \emph{local meter} which has to monitor position of a small ($1\div10$ gram) local mirror and which precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter back-action noise and measurement noise is introduced, which allows to eliminate the back-action noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment about 10 meter long filter cavity can be used to obtain sensitivity approximately $2\div3$ times better than the SQL. For future QND gravitational-wave detectors with sensitivity about ten times better than the SQL, the filter cavity length should be within kilometer range.

gr-qc↗

Sub-SQL Sensitivity via Optical Rigidity in Advanced LIGO Interferometer with Optical Losses

The ``optical springs'' regime of the signal-recycled configuration of laser interferometric gravitational-wave detectors is analyzed taking in account optical losses in the interferometer arm cavities. This regime allows to obtain sensitivity better than the Standard Quantum Limits both for a free test mass and for a conventional harmonic oscillator. The optical losses restrict the gain in sensitivity and achievable signal-to-noise ratio. Nevertheless, for parameters values planned for the Advanced LIGO gravitational-wave detector, this restriction is insignificant.

gr-qc↗

To the practical design of the optical lever intracavity topology of gravitational-wave detectors

The QND intracavity topologies of gravitational-wave detectors proposed several years ago allow, in principle, to obtain sensitivity significantly better than the Standard Quantum Limit using relatively small anount of optical pumping power. In this article we consider an improved more ``practical'' version of the optical lever intracavity scheme. It differs from the original version by the symmetry which allows to suppress influence of the input light amplitude fluctuation. In addition, it provides the means to inject optical pumping inside the scheme without increase of optical losses. We consider also sensitivity limitations imposed by the local meter which is the key element of the intracavity topologies. Two variants of the local meter are analyzed, which are based on the spectral variation measurement and on the Discrete Sampling Variation Measurement, correspondingly. The former one, while can not be considered as a candidate for a practical implementation, allows, in principle, to obtain the best sensitivity and thus can be considered as an ideal ``asymptotic case'' for all other schemes. The DSVM-based local meter can be considered as a realistic scheme but its sensitivity, unfortunately, is by far not so good just due to a couple of peculiar numeric factors specific for this scheme. From our point of view search of new methods of mechanical QND measurements probably based on improved DSVM scheme or which combine the local meter with the pondermotive squeezing technique, is necessary.

gr-qc↗

Reducing the mirrors coating noise in laser gravitational-wave antennae by means of double mirrors

Recent researches show that the fluctuations of the dielectric mirrors coating thickness can introduce a substantial part of the future laser gravitational-wave antennae total noise budget. These fluctuations are especially large in the high-reflectivity end mirrors of the Fabry-Perot cavities which are being used in the laser gravitational-wave antennae. We show here that the influence of these fluctuations can be substantially decreased by using additional short Fabry-Perot cavities, tuned in anti-resonance instead of the end mirrors.

gr-qc↗

Low pumping energy mode of the "optical bars''/"optical lever" topologies of gravitational-wave antennae

The ``optical bars''/``optical lever'' topologies of gravitational-wave antennae allow to obtain sensitivity better that the Standard Quantum Limit while keeping the optical pumping energy in the antenna relatively low. Element of the crucial importance in these schemes is the local meter which monitors the local test mirror position. Using cross-correlation of this meter back-action noise and its measurement noise it is possible to further decrease the optical pumping energy. In this case the pumping energy minimal value will be limited by the internal losses in the antenna only. Estimates show that for values of parameters available for contemporary and planned gravitational-wave antennae, sensitivity about one order of magnitude better than the Standard Quantum Limit can be obtained using the pumping energy about one order of magnitude smaller energy than is required in the traditional topology in order to obtain the the Standard Quantum Limit level of sensitivity.

gr-qc↗

Quantum speedmeter and laser interferometric gravitational-wave antennae

A new topology of laser interferometric gravitational-wave antenna is considered. It is based on two schemes: {\em quantum speedmeter} and {\em zero-area Sagnac interferometer} and allows to obtain sensitivity better than the Standard Quantum Limit in wide band without any large-scale modifications of the standard topology of the laser interferometric antennae.

gr-qc↗

Stroboscopic Variation Measurement

A new procedure of the linear position measurement which allows to obtain sensitivity better than the Standard Quantum Limit and close to the Energetic Quantum Limit is proposed and analyzed in details. Proposed method is based on the principles of stroboscopic quantum measurement and variation quantum measurement and allows to avoid main disadvantages of both these procedures. This method can be considered as a good candidate for use as a local position meter in the ``intracavity'' topologies of the laser gravitational-wave antennae.

gr-qc↗

The "optical lever" intracavity readout scheme for gravitational-wave antennae

An improved version of the ``optical bar'' intracavity readout scheme for gravitational-wave antennae is considered. We propose to call this scheme ``optical lever'' because it can provide significant gain in the signal displacement of the local mirror similar to the gain which can be obtained using ordinary mechanical lever with unequal arms. In this scheme displacement of the local mirror can be close to the signal displacement of the end mirrors of hypothetical gravitational-wave antenna with arm lengths equal to the half-wavelength of the gravitational wave.

gr-qc↗

Speed Meter As a Quantum Nondemolition Measuring Device for Force

Quantum noise is an important issue for advanced LIGO. Although it is in principle possible to beat the Standard Quantum Limit (SQL), no practical recipe has been found yet. This paper dicusses quantum noise in the context of speedmeter-a devise monitoring the speed of the testmass. The scheme proposed to overcome SQL in this case might be more practical than the methods based on monitoring position of the testmass.

gr-qc↗