SearcharxivSearch

arXiv subjects

Fabian Allmendinger

Publications and source records attributed to Fabian Allmendinger.

4 recordsLinked to original sources

Multimodal classification of Radiation-Induced Contrast Enhancements and tumor recurrence using deep learning

The differentiation between tumor recurrence and radiation-induced contrast enhancements in post-treatment glioblastoma patients remains a major clinical challenge. Existing approaches rely on clinically sparsely available diffusion MRI or do not consider radiation maps, which are gaining increasing interest in the tumor board for this differentiation. We introduce RICE-NET, a multimodal 3D deep learning model that integrates longitudinal MRI data with radiotherapy dose distributions for automated lesion classification using conventional T1-weighted MRI data. Using a cohort of 92 patients, the model achieved an F1 score of 0.92 on an independent test set. During extensive ablation experiments, we quantified the contribution of each timepoint and modality and showed that reliable classification largely depends on the radiation map. Occlusion-based interpretability analyses further confirmed the model's focus on clinically relevant regions. These findings highlight the potential of multimodal deep learning to enhance diagnostic accuracy and support clinical decision-making in neuro-oncology.

cs.CV

Degaussing Procedure and Performance Enhancement by Low-Frequency Shaking of a 3-Layer Magnetically Shielded Room

We report on the performance of a Magnetically Shielded Room (MSR) intended for next level $^3$He/$^{129}$Xe co-magnetometer experiments which require improved magnetic conditions. The MSR consists of three layers of Mu-metal with a thickness of 3 mm each, and one additional highly conductive copper-coated aluminum layer with a thickness of 10 mm. It has a cubical shape with an walk-in interior volume with an edge length of 2560 mm. An optimized degaussing (magnetic equilibration) procedure using a frequency sweep with constant amplitude followed by an exponential decay of the amplitude will be presented. The procedure for the whole MSR takes 21 minutes and measurements of the residual magnetic field at the center of the MSR show that $|B|<1$ nT can be reached reliably. The chosen degaussing procedure will be motivated by online hysteresis measurements of the assembled MSR and by Eddy current simulations showing that saturation at the center of the Mu-metal layer is reached. Shielding Factors can be improved by a factor $\approx 4$ in all directions by low frequency (0.2 Hz), low current (1 A) shaking of the outermost Mu-metal layer.

physics.ins-det

Limit on Lorentz-Invariance- and CPT-Violating Neutron Spin Interactions Using a $^3$He-$^{129}$Xe Comagnetometer

We performed a search for a Lorentz-invariance- and CPT-violating coupling of the $^3$He and $^{129}$Xe nuclear spins to posited background fields. Our experimental approach is to measure the free precession of nuclear spin polarized $^3$He and $^{129}$Xe atoms using SQUID detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the co-located spin samples. As a result we obtain an upper limit on the equatorial component of the background field $\tilde{b}^n_{\bot}< 8.4 \cdot 10^{-34}$ GeV (68\% C.L.). Furthermore, this technique was modified to search for an electric dipole moment (EDM) of $^{129}$Xe.

hep-ph

Constraints on Spin-Dependent Short-Range Interaction between Nucleons

We report on the search for a new spin-dependent P- and T-violating interaction between nucleons mediated by light, pseudoscalar bosons such as the axion which was invented to solve the strong CP problem. Our experimental approach is to use an ultra-sensitive low-field magnetometer based on the detection of free precession of co-located 3He and 129Xe nuclear spins using SQUIDs as low-noise magnetic flux detectors. In the presence of an unpolarized mass the precession frequency shif

hep-ex