SearcharxivSearch

arXiv subjects

Fabian Mohn

Publications and source records attributed to Fabian Mohn.

14 recordsLinked to original sources

Impact of Structural Design on Magneto-Mechanical Resonators: The Case of a Jewel Bearing Variant

Magneto-mechanical resonators (MMRs) are passive, wirelessly read sensors whose small size, miniaturizability, and low cost make them attractive for tracking and for sensing physical and chemical quantities. Their operation is based on a permanent-magnet rotor whose mechanical resonance encodes the sensing and tracking information. The bearing that suspends this rotor is therefore decisive both for the in-operation performance and for the manufacturability of the device. The original design suspends the rotor on a thin thread, which is nontrivial to assemble. This work investigates the impact of that structural design choice by introducing an alternative bearing in which the spherical rotor magnet rests in a cup-shaped industrial jewel. A dynamic model of this Jewel-MMR is derived, including the angle-dependent dry friction torque at the jewel contact. From it, a geometric trade-off between friction torque and resilience against unwanted oscillation modes is identified and quantified. Since the conventional quality factor loses its meaning under dominant dry friction, a two-tiered framework is proposed that compares MMR variants by estimation precision at equal magnet size and natural frequency. Both variants are characterized at a fixed pose on a Helmholtz-coil detection platform. The Jewel-MMR is self-aligning and assembled in less than half the time from fewer parts. Its response signal decays faster, so that under laboratory noise conditions the natural frequency and the orientation are recovered more precisely from the thread variant. The jewel bearing, however, tolerates a considerably larger deflection angle and thus a stronger signal, which reverses this relation above an experimentally determined noise level and indicates an advantage wherever the signal-to-noise ratio is reduced.

physics.app-ph

Parameter Estimation for Model-Based Sensing of Magneto-Mechanical Resonators

Magneto-mechanical resonators (MMRs) represent a recently proposed type of passive sensor that enables the estimation of its pose as well as sensing other parameters in its environment. The working principle of MMRs entails an excitation of the sensors by oscillating magnetic fields, followed by a readout process facilitated by inductive receiver coils. The sensing technology relies on real-time parameter estimation. This encompasses the solution of a nonlinear inverse problem, with the induced signals and a suitable forward model as inputs. The aim of this paper is twofold: first, to introduce a reference model and simplified models for the MMR dynamics and inductive readout, and second, to provide robust and real-time capable methods to estimate the model parameters. The effectiveness of the presented methods is evaluated in terms of their real-time potential, precision, and accuracy. All presented methods demonstrate the capacity to estimate the measured signal, with the simplified methods reducing the corresponding parameter estimation time by up to two orders of magnitude at the expense of less than 4 % deviation for large maximum deflection angles.

physics.app-ph

Natural Frequency Dependency of Magneto-Mechanical Resonators on Magnet Distance

The precise derivation of physical quantities like temperature or pressure at arbitrary locations is useful in numerous contexts, e.g. medical procedures or industrial process engineering. The novel sensor technology of magneto-mechanical resonators (MMR), based on the interaction of a rotor and stator permanent magnet, allows for the combined tracking of the sensor position and orientation while simultaneously sensing an external measurand. Thereby, the quantity is coupled to the torsional oscillation frequency, e.g. by varying the magnet distance. In this paper, we analyze the (deflection angle-independent) natural frequency dependency of MMR sensors on the rotor-stator distance, and evaluate the performance of theoretical models. The three presented sensors incorporate magnets of spherical and/or cylindrical geometry and can be operated at adjustable frequencies within the range of 61.9-307.3 Hz. Our proposed method to obtain the natural frequency demonstrates notable robustness to variations in the initial deflection amplitudes and quality factors resulting in statistical errors on the mean smaller than 0.05 %. We find that the distance-frequency relationship is well described by an adapted dipole model accounting for material and manufacturing uncertainties. Their combined effect can be compensated by an adjustment of a single parameter which drives the median model deviation generally below 0.2 %. Our depicted methods and results are important for the design and calibration process of new sensor types utilizing the MMR technique.

physics.app-ph

Real-Time 3D Magnetic Field Camera for a Spherical Volume

Accurate and efficient volumetric magnetic field measurements are essential for a wide range of applications. Conventional methods are often limited in terms of measurement speed and applicability, or suffer from scaling problems at larger volumes. This work presents the development of a magnetometer array designed to measure magnetic fields within a spherical volume at a frame rate of 10 Hz. The array consists of 3D Hall magnetometers positioned according to a spherical $t$-design, allowing simultaneous magnetic field data acquisition from the surface of the sphere. The approach enables the efficient representation of all three components of the magnetic field inside the sphere using a sixth-degree polynomial, significantly reducing measurement time compared to sequential methods. This work details the design, calibration, and measurement methods of the array. To evaluate its performance, we compare it to a sequential single-sensor measurement by examining a magnetic gradient field. The obtained measurement uncertainties of approx. 1% show the applicability for a variety of applications.

physics.app-ph

Wireless and passive pressure detection using magneto-mechanical resonances in process engineering

A custom-developed magneto-mechanical resonator (MMR) for wireless pressure measurement is investigated for potential applications in process engineering. The MMR sensor utilises changes in the resonance frequency caused by pressure on a flexible 3D printed membrane. The thickness of the printed membrane plays a crucial role in determining the performance and sensitivity of MMRs, and can be tailored to meet the requirements of specific applications. The study includes static and dynamic measurements to determine the pressure sensitivity and temporal resolution of the sensor. The results show a minimum sensitivity of $0.06~\text{Hz mbar}^{-1}$ and are in agreement with theoretical calculations and measurements. The maximum sensor readout frequency is $2~\text{Hz}$ in this study. Additionally, the temperature dependence of the sensor is investigated, revealing a significant dependence of the resonance frequency on temperature. The developed MMR offers a promising and versatile method for precise pressure measurements in process engineering environments.

physics.app-ph

Low-cost analog signal chain for transmit-receive circuits of passive induction-based resonators

Passive wireless sensors are crucial in modern medical and industrial settings to monitor procedures and conditions. We demonstrate a circuit to inductively excite passive resonators and to conduct their decaying signal response to a low noise amplifier. Two design variations of a generic transmit-receive signal chain are proposed, measured, and described in detail for the purpose of facilitating replication. Instrumentation and design aim to be scalable for multi-channel array configurations, using either off-the-shelf class-D audio amplifiers or a custom full H-bridge. Measurements are conducted on miniature magneto-mechanical resonators in the ultra low frequency range to enable sensing and tracking applications of such devices in different environments.

eess.SP

Characterization of the Clinically Approved MRI Tracer Resotran for Magnetic Particle Imaging in a Comparison Study

Objective. The availability of magnetic nanoparticles with medical approval for human intervention is fundamental to the clinical translation of magnetic particle imaging (MPI). In this work, we thoroughly evaluate and compare the magnetic properties of an magnetic resonance imaging (MRI) approved tracer to validate its performance for MPI in future human trials. Approach. We analyze whether the recently approved MRI tracer Resotran is suitable for MPI. In addition, we compare Resotran with the previously approved and extensively studied tracer Resovist, with Ferrotran, which is currently in a clinical phase III study, and with the tailored MPI tracer Perimag. Main results. Initial magnetic particle spectroscopy measurements indicate that Resotran exhibits performance characteristics akin to Resovist, but below Perimag. We provide data on four different tracers using dynamic light scattering, transmission electron microscopy, vibrating sample magnetometry measurements, magnetic particle spectroscopy to derive hysteresis, point spread functions, and a serial dilution, as well as system matrix based MPI measurements on a preclinical scanner (Bruker 25/20 FF), including reconstructed images. Significance. Numerous approved magnetic nanoparticles used as tracers in MRI lack the necessary magnetic properties essential for robust signal generation in MPI. The process of obtaining medical approval for dedicated MPI tracers optimized for signal performance is an arduous and costly endeavor, often only justifiable for companies with a well-defined clinical business case. Resotran is an approved tracer that has become available in Europe for MRI. In this work, we study the eligibility of Resotran for MPI in an effort to pave the way for human MPI trials.

physics.med-ph

Resonant Inductive Coupling Network for Human-Sized Magnetic Particle Imaging

In Magnetic Particle Imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass filter and the drive-field generator is required. Here, for reasons of safety in future human scanners, a symmetrical topology and a transformer, called inductive coupling network is used. Our primary objectives are to achieve floating potentials to ensure patient safety, attaining high linearity and high gain for the resonant transformer. We present a novel systematic approach to the design of a loss-optimized resonant toroid with a D-shaped cross section, employing segmentation to adjust the inductance-to-resistance ratio while maintaining a constant quality factor. Simultaneously, we derive a specific matching condition of a symmetric transmit-receive circuit for magnetic particle imaging. The chosen setup filters the fundamental frequency and allows simultaneous signal transmission and reception. In addition, the decoupling of multiple drive field channels is discussed and the primary side of the transformer is evaluated for maximum coupling and minimum stray field. Two prototypes were constructed, measured, decoupled, and compared to the derived theory and to method-of-moment based simulations.

eess.SP

System Characterization of a Human-Sized 3D Real-Time Magnetic Particle Imaging Scanner for Cerebral Applications

Since the initial patent in 2001, the Magnetic Particle Imaging (MPI) community has been striving to develop an MPI scanner suitable for human applications. Numerous contributions from different research fields, regarding tracer development, reconstruction methods, hardware engineering, and sequence design have been employed in pursuit of this objective. In this work, we introduce and thoroughly characterize an improved head-sized MPI scanner with an emphasis on human safety. The scanner is operated by open-source software that enables scanning, monitoring, analysis, and reconstruction, designed to be handled by end users. Our primary focus is to present all technical components of the scanner, with the ultimate objective to investigate brain perfusion imaging in phantom experiments. We have successfully achieved full 3D single- and multi-contrast imaging capabilities at a frame rate of 4 Hz with sufficient sensitivity and resolution for brain applications. To assess system characterization, we devised sensitivity, resolution, perfusion, and multi-contrast experiments, as well as field measurements and sequence analysis. The acquired images were captured using a clinically approved tracer and suitable magnetic field strengths, while adhering to the established human peripheral nerve stimulation thresholds. This advanced scanner holds potential as a tomographic imager for diagnosing conditions such as ischemic stroke or intracranial hemorrhage in environments lacking electromagnetic shielding. Furthermore, due to its low power consumption it may have the potential to facilitate long-term monitoring within intensive care units for various applications.

physics.med-ph

Saline bolus for negative contrast perfusion imaging in magnetic particle imaging

Objective. Magnetic Particle Imaging (MPI) is capable of high temporal resolution measurements of the spatial distribution of magnetic nanoparticles and therefore well suited for perfusion imaging, which is an important tool in medical diagnosis. Perfusion imaging in MPI usually requires a fresh bolus of tracer material to capture the key signal dynamics. Here, we propose a method to decouple the imaging sequence from the injection of additional tracer material, without further increasing the administered iron dose in the body with each image. Approach. A bolus of physiological saline solution without any particles (negative contrast) diminishes the steady-state concentration of a long-circulating tracer during passage. This depression in the measured concentration contributes to the required contrast dynamics. The presence of a long-circulating tracer is therefore a prerequisite to obtain the negative contrast. As a quantitative tracer based imaging method, the signal is linear in the tracer concentration for any location that contains nanoparticles and zero in the surrounding tissue which does not provide any intrinsic signal. After tracer injection, the concentration over time (positive contrast) can be utilized to calculate dynamic diagnostic parameters like perfusion parameters in vessels and organs. Every acquired perfusion image thus requires a new bolus of tracer with a sufficiently large iron dose to be visible above the background. Main results. Perfusion parameters are calculated based on the time response of the proposed negative bolus and compared to a positive bolus. Results from phantom experiments show that normalized signals from positive and negative boli are concurrent and deviations of calculated perfusion maps are low. Significance. Our method opens up the possibility to increase the total monitoring time, while minimizing the iron dose per acquired image.

physics.med-ph

System Matrix based Reconstruction for Pulsed Sequences in Magnetic Particle Imaging

Improving resolution and sensitivity will widen possible medical applications of magnetic particle imaging. Pulsed excitation promises such benefits, at the cost of more complex hardware solutions and restrictions on drive field amplitude and frequency. State-of-the-art systems utilize a sinusoidal excitation to drive superparamagnetic nanoparticles into the non-linear part of their magnetization curve, which creates a spectrum with a clear separation of direct feed-through and higher harmonics caused by the particles response. One challenge for rectangular excitation is the discrimination of particle and excitation signals, both broad-band. Another is the drive-field sequence itself, as particles that are not placed at the same spatial position, may react simultaneously and are not separable by their signal phase or shape. To overcome this potential loss of information in spatial encoding for high amplitudes, a superposition of shifting fields and drive-field rotations is proposed in this work. Upon close view, a system matrix approach is capable to maintain resolution, independent of the sequence, if the response to pulsed sequences still encodes information within the phase. Data from an Arbitrary Waveform Magnetic Particle Spectrometer with offsets in two spatial dimensions is measured and calibrated to guarantee device independence. Multiple sequence types and waveforms are compared, based on frequency space image reconstruction from emulated signals, that are derived from measured particle responses. A resolution of 1.0 mT (0.8 mm for a gradient of (-1.25,\,-1.25,\,2.5) T/m) in x- and y-direction was achieved and a superior sensitivity for pulsed sequences was detected on the basis of reference phantoms.

physics.med-ph

Interactions between two C60 molecules measured by scanning probe microscopies

C60-functionalized tips are used to probe C60 molecules on Cu(111) with scanning tunneling and atomic force microscopy. Distinct and complex intramolecular contrasts are found. Maximal attractive forces are observed when for both molecules a [6,6] bond faces a hexagon of the other molecule. Density functional theory calculations including parameterized van der Waals interactions corroborate the observations.

cond-mat.mes-hall

Investigating Atomic Contrast in Atomic Force Microscopy and Kelvin Probe Force Microscopy on Ionic Systems using Functionalized Tips

Noncontact atomic force microscopy (NC-AFM) and Kelvin probe force microscopy (KPFM) have become important tools for nanotechnology; however, their contrast mechanisms on the atomic scale are not entirely understood. Here we used chlorine vacancies in NaCl bilayers on Cu(111) as a model system to investigate atomic contrast as a function of applied voltage, tip height, and tip functionalization. We demonstrate that the AFM contrast on the atomic scale decisively depends on both the tip termination and the sample voltage. On the contrary, the local contact potential difference (LCPD) acquired with KPFM showed the same qualitative contrast for all tip terminations investigated, which resembled the contrast of the electric field of the sample. We find that the AFM contrast stems mainly from electrostatic interactions but its tip dependence cannot be explained by the tip dipole alone. With the aid of a simple electrostatic model and by density functional theory we investigate the underlying contrast mechanisms.

cond-mat.mes-hall

Force and Conductance during contact formation to a C60 molecule

Force and conductance were simultaneously measured during the formation of Cu-C60 and C60-C60 contacts using a combined cryogenic scanning tunneling and atomic force microscope. The contact geometry was controlled with submolecular resolution. The maximal attractive forces measured for the two types of junctions were found to differ significantly. We show that the previously reported values of the contact conductance correspond to the junction being under maximal tensile stress.

cond-mat.mes-hall