SearcharxivSearch

arXiv subjects

Fabio Acerbi

Publications and source records attributed to Fabio Acerbi.

8 recordsLinked to original sources

The Darkside-20k Data Acquisition System

DarkSide-20k is a WIMP search experiment using liquid argon as a target, designed to perform a background-free search for dark matter with unprecedented sensitivity, and is currently under construction at INFN Laboratori Nazionali del Gran Sasso, Italy. The detector comprises a dual-phase Time Projection Chamber complemented with external veto systems and is equipped with a total of 2720 SiPM-based readout channels. This work presents the DAQ system designed for DarkSide-20k. The system is capable of continuous, triggerless digitisation of the waveforms with high single-photoelectron detection efficiency and online processing, ensuring data reduction for long-term storage. The DarkSide-20k DAQ system employs commercial CAEN VX2745 digitisers with custom FPGA firmware implementation. Timing and synchronisation across all 48 digitisers are provided by custom Global and Crate Data Manager boards distributing a phase-aligned clock derived from a disciplined rubidium standard. Waveform segments are processed in real time by Front End Processor machines. Data are organised into collections containing whole detector information and distributed across a farm of Time Slice Processors for event reconstruction, classification, and further reduction before storage and offline analysis. A full "Quadrant" of the system, corresponding to one quarter of the final DAQ, has been assembled and validated at TRIUMF laboratory in Canada. The Quadrant has been stress-tested with simultaneous pulses and demonstrated sustained digitizer readout exceeding expected physics rates and stable long-term performance.

physics.ins-det

Position-Sensitive Silicon Photomultiplier Array with Enhanced Position Reconstruction by means of a Deep Neural Network

Single-photon sensitive detectors like Silicon Photomultipliers are widely used in many medical imaging applications. By using detectors with position resolutions, it is possible to build compact photodetector readouts with reduced number of channels, but still preserving position resolution and gamma-rays imaging capabilities. In this work, we present the advantage of using a Deep Neural Networks (DNNs) light position reconstruction applied to a 2x2 array of linearly-graded SiPMs (LG-SiPMs), to minimize the distortions on the reconstructed event maps. Our approach significantly enhances both the resolution and linearity of position detection compared to the nominal reconstruction formula based on the device architecture. Remarkably, the DNN-based reconstruction boosts the number of resolved areas (pixels) by a factor of 5.7 to 12.1 (depending the training splitting used) allowing for a higher level of precision and performance in light detection.

physics.ins-det

Performance Evaluation of a Position-Sensitive SiPM-based Gamma Camera for Intraoperative Imaging

The POSiCS camera is a handheld, small field-of-view gamma camera developed for multipurpose use in radio-guided surgery (RGS), with sentinel lymph node biopsy (SLNB) as its benchmark application. This compact and lightweight detector (weighing approximately 350 g) can map tissues labeled with Tc-99m nanocolloids and guide surgeons to the location of target lesions. By enabling intraoperative visualization in close proximity to the surgical field, its primary objective is to minimize surgical interventional invasiveness and operative time, thereby enhancing localization accuracy and reducing the incidence of post-operative complications. The design and components of the POSiCS camera emphasize ergonomic handling and compactness, providing, at the same time, rapid image formation and a spatial resolution of a few millimeters. These features are compatible with routine operating-room workflow, including wireless communication with the computer and a real-time display to support surgeon decision-making. The spatial resolution measured at a source-detector distance of 0 cm was 1.9 +/- 0.1 mm for the high-sensitivity mode and 1.4 +/- 0.1 mm for the high-resolution mode. The system sensitivity at 2 cm was evaluated as 481 +/- 14 cps/MBq (high sensitivity) and 134 +/- 8 cps/MBq (high resolution). For both working modes, we report an energy resolution of approximately 20 percent, even though the high-resolution collimator exhibits an increased scattered component due to the larger amount of tungsten.

physics.med-ph

Characterization of FBK NUV-HD-Cryo SiPMs near LHe temperature

Five FBK ``NUV-HD-Cryo'' SiPMs have been characterized at 7 K and 10 K, with 405 nm and 530 nm LED light, respectively. The dark count rate (DCR) was measured to be $\sim$ 1 Hz for the $\sim$ 100 mm$^2$-size SiPMs, or 0.01 Hz/mm$^2$, which is $\sim$ 7 orders lower than the DCR at room temperature (RT). Given the very low DCR at these cryogenic temperatures, we measured the SiPMs' I-V curves with such a method: illuminated the SiPMs with weak light, which differs from the conventional measurements at RT. Then, we measured the photo-detection efficiency (PDE), after-pulse (AP), and cross-talk (CT) with a bias voltage ranging from overvoltage (OV) 5 to 11 V. At the OV interval (5 to 11 V), the PDE was between 20\% - 45\%, and the AP and CT were both between $\sim$ 5\% and $\sim$ 20\%. With an OV higher than 10 V, the PDE would be $\ge$ 40\%, and the AP and CT are $\sim$ 20\%. Combining all of the measurements, we are confident that the SiPMs can be equipped as the photosensors on liquid helium detectors, including but not limited to the time projection chambers, which we have proposed in hunting for low-mass dark matter directly and beyond.

physics.ins-det

Quantitative Determination of Spatial Resolution and Linearity of Position-Sensitive LG-SiPMs at Sub-Millimeter Scale via Ricean Distribution Fitting

Position-sensitive SiPMs are useful in all light detection applications requiring a small number of readout channels while preserving the information about the incoming light's interaction position. Focusing on a 2x2 array of LG-SiPMs covering an area of $\sim 15.5 \times 15.5~\rm{mm}$ with just 6 readout channels, we proposed a quantitative method to evaluate image reconstruction performance. The method is based on a statistical approach to assess the device's precision (spatial resolution) and accuracy (linearity) in reconstructing the light spot center of gravity. This evaluation is achieved through a Rice probability distribution function fitting. We obtained an average sensor spatial resolution's best value of $81 \pm 3~\rm{μm}$ (standard deviation), which is achieved by reconstructing each position with the amplitude of the channels' output signals. The corresponding accuracy is $231 \pm 4~\rm{μm}$.

physics.ins-det

Radiation damage on Silicon Photomultipliers from ionizing and non-ionizing radiation of low-earth orbit operations

Silicon Photomultipliers (SiPMs) are single photon detectors that gained increasing interest in many applications as an alternative to photomultiplier tubes. In particular in the field of space experiments, where volume, weight and power consumption are a major constraint, their advantages like compactness, ruggedness, and their potential to achieve high quantum efficiency from UV to NIR, makes them ideal candidates for spaceborne, low photon flux detectors. During space missions however, SiPMs are usually exposed to high levels of radiation, both ionizing and non-ionizing, which can deteriorate the performance of these detectors over time. The goal of this work is to compare process and layout variation of SiPMs in terms of their radiation damage effects to identify the features that helps reducing the deterioration of the performance and develop the next generation of more radiation tolerant detectors. To do this we irradiated with protons and X-rays several NUV-HD SiPMs with small area (single microcell, 0.2x0.2 mm2 and 1x1 mm2) produced in FBK. We performed online current-voltage measurements right after each irradiation step and a complete functional characterization before and after irradiation. We compare the results and show the most promising variations for future production of SiPMs for space applications.

physics.ins-det

Radiation damage on SiPMs for Space Applications

Silicon Photo-multipliers (SiPMs) are very sensitive photo-detectors that experienced a big development in the last years in several applications, like LIDAR, astrophysics, medical imaging and high energy physics (HEP) experiments. In HEP experiments, in particular, they are often exposed to significant radiation doses. The main purpose of this manuscript is the characterization of several FBK SiPM technologies when exposed to 74 $MeV$ protons with a total fluence comparable to the one that they would experience in space along circular Low Earth Orbits (LEO), Polar, during a five years mission. In this work, we estimated the expected proton fluences along the selected orbit, by means of the SPENVIS software. Several fluence steps were chosen to consider dense fluence intervals and have a more accurate sight on the whole damage process. We estimated a maximum fluence achieved during the tests of $6.4 \times 10^{11}$ $n_{eq}/cm^2$. Based on such simulations, we irradiated several SiPM technologies. We developed a custom experimental setup, which was used to perform online reverse voltage-current, right after each irradiation step, to minimize the effect of the annealing on the measurement. The results are then displayed, in particular the currents, the noise and the Photon Detection Efficiency. Also a 30-days study on the annealing of the devices was performed. Lastly, the conclusions are drawn on the basis of the Signal-to-Noise Ratio (SNR), taking into account the standard parameters of famous satellites using similar orbits as the ones considered into this work.

physics.ins-det

Cryogenic Characterization of FBK HD Near-UV Sensitive SiPMs

We report on the characterization of near-ultraviolet high density silicon photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and correlated noise of the \SiPMs\ between 40 and 300~K. Moreover, an analysis program and data acquisition system were developed to allow the precise characterization of these parameters, some of which can vary up to 7 orders of magnitude between room temperature and 40~K. We demonstrate that it is possible to operate the \FBK\ near-ultraviolet high density \SiPMs\ at temperatures lower than 100~K with a dark rate below 0.01 cps/mm$^2$ and total correlated noise probability below 35\% at an over-voltage of 6~V. These results are relevant for the development of future cryogenic particle detectors using \SiPMs\ as photosensors.

physics.ins-det