Searcharxiv⌕ Search

arXiv subjects

Fabricio Alcalde Bessia

Publications and source records attributed to Fabricio Alcalde Bessia.

8 recordsLinked to original sources

Scalable Multiple Electron Transport Architectures for Feedback Traceable Current Sources

We present a scalable electron-counting current cell based on a floating gate architecture operated as a Multiple Electron Transport device (MET). The system enables controlled injection, transport, and precise quantification of discrete charge packets using the sensor non-destructive multiple readout capability. We repurposed the charge-injection technique, jointly with the electron-resolution capability, for a controlled generation of quantized charge packets for an electron-traceable current source. Scalable architectures based on parallel and series multi-amplifier configurations are explored. Experimental results confirm noise reduction following the square root of the number of independent measurements and demonstrate stable, programmable output current. This approach provides a compact and scalable platform for electron-counting current sources and precision quantum metrology applications.

cond-mat.mes-hall↗

Absorption and Phase-Contrast Microtomography Using Direct X-ray Detection With COTS CMOS Sensors

This work presents a high-resolution X-ray microtomography system that uses commercial off-the-shelf (COTS) CMOS image sensors as direct detectors, relying on the sensor s intrinsic resolution to achieve tomographic reconstructions without optical components. The system employs a microfocus X-ray source in cone-beam geometry, enabling both absorption-contrast and propagation-based phase-contrast imaging. A dynamic flat-field correction algorithm mitigates radiation-induced degradation during long acquisitions, helping to overcome limitations of consumer-grade hardware. The setup provides voxel sizes from 3.9 micron to 5.2 micron. Phase contrast visualizes soft tissue boundaries that would be undetectable by conventional radiography. Compared to synchrotron or nanofocus systems, our solution is simpler, lower-cost, and avoids complex optics or slow scans. COTS CMOS sensors appear as a viable alternative for laboratory-scale high-resolution microtomography.

eess.IV↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

physics.ins-det↗

Skipper-in-CMOS: Non-Destructive Readout with Sub-Electron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the non-destructive readout capability of Skipper Charge Coupled Devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode in a CMOS imaging process, while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a 15 x 15 um^2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor's commercial 180 nm CMOS Image Sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep sub-electron noise of 0.15rms e-, demonstrating the charge transfer operation from the pinned photodiode and the single photon counting operation when the sensor is exposed to light. The article also discusses new testing strategies employed for its operation and characterization.

astro-ph.IM↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The \emph{MIDNA} application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${μν}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

physics.app-ph↗

The Oscura Experiment

The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.

astro-ph.IM↗

X-ray characterization of BUSARD chip: A HV-SOI monolithic particle detector with pixel sensors under the buried oxide

This work presents the design of BUSARD, an application specific integrated circuit (ASIC) for the detection of ionizing particles. The ASIC is a monolithic active pixel sensor which has been fabricated in a High-Voltage Silicon-On-Insulator (HV-SOI) process that allows the fabrication of a buried N+ diffusion below the Buried OXide (BOX) as a standard processing step. The first version of the chip, BUSARD-A, takes advantage of this buried diffusion as an ionizing particle sensor. It includes a small array of 13$\times$13 pixels, with a pitch of $80\,μ$m, and each pixel has one buried diffusion with a charge amplifier, discriminator with offset tuning and digital processing. The detector has several operation modes including particle counting and Time-over-Threshold (ToT). An initial X-ray characterization of the detector was carried out, obtaining several pulse height and ToT spectra, which then were used to perform the energy calibration of the device. The Molybdenum $\mathbf{K_α}$ emission was measured with a standard deviation of $127\,e^{-}$ of ENC by using the analog pulse output, and with $276\,e^{-}$ of ENC by using the ToT digital output. The resolution in ToT mode is dominated by the pixel-to-pixel variation.

physics.ins-det↗

Analog pile-up circuit technique using a single capacitor for the readout of Skipper-CCD detectors

With Skipper-CCD detectors it is possible to take multiple samples of the charge packet collected on each pixel. After averaging the samples, the noise can be extremely reduced allowing the exact counting of electrons per pixel. In this work we present an analog circuit that, with a minimum number of components, applies a double slope integration (DSI), and at the same time, it averages the multiple samples producing at its output the pixel value with sub-electron noise. For this prupose, we introduce the technique of using the DSI integrator capacitor to add the skipper samples. An experimental verification using discrete components is presented, together with an analysis of its noise sources and limitations. After averaging 400 samples it was possible reach a readout noise of 0.2\,$e^-_{RMS}/pix$, comparable to other available readout systems. Due to its simplicity and significant reduction of the sampling requirements, this circuit technique is of particular interest in particle experiments and cameras with a high density of Skipper-CCDs.

physics.ins-det↗