SearcharxivSearch

arXiv subjects

Fakrul Islam Tushar

Publications and source records attributed to Fakrul Islam Tushar.

At least 19 recordsLinked to original sources

Distilling CT Foundation Models into Editable Concept Bottlenecks for Lung Nodule Malignancy Prediction

Foundation models provide transferable CT representations, but predictions based directly on these embeddings are difficult to interpret. We developed concept bottleneck models that map two frozen CT foundation-model representations to eight radiologist-defined pulmonary-nodule attributes and predict malignancy from the estimated concepts and nodule size. The models included CT-FM, a whole-CT self-supervised encoder using a 96^3-voxel nodule-centered patch, and FMCIB, a nodule-focused contrastive encoder using a 50-mm crop. Eight ridge-regression concept heads were trained on 2,610 LIDC-IDRI nodules. Malignancy models were trained on LUNA25 and evaluated on a held-out internal test set and the external DLCS cohort. Concept fidelity was assessed using five-fold cross-validated R^2, and malignancy discrimination was assessed using AUROC with 95% confidence intervals estimated by patient-grouped bootstrap resampling. Concept fidelity was modest but higher for FMCIB than CT-FM for subtlety (R2, 0.24 vs. 0.11), spiculation (0.17 vs. 0.08), texture (0.17 vs. 0.07), and lobulation (0.15 vs. 0.05). Internally, the CT-FM and FMCIB concept+size models achieved AUROCs of 0.86 (95% CI, 0.80-0.92) and 0.86 (0.79-0.92), respectively. Externally, AUROCs were 0.72 (0.68-0.75) and 0.73 (0.70-0.76), compared with 0.73 for nodule size alone and 0.60 and 0.67 for the corresponding embedding only probes. Additive predictions could be decomposed into feature-level contributions and modified through controlled concept interventions. Concept bottlenecks provided transparent malignancy predictions with discrimination similar to nodule size alone, while differences in concept fidelity suggest that concept recovery depends on the underlying foundation-model representation.

cs.CV

Zero-Shot Multi-Disease Labeling of Chest, Abdomen, and Pelvis CT Reports Using Open-Weight Large Language Models: The Effect of Labeling Conventions

Purpose: To compare five lightweight open-weight large language models (LLMs) with a rule-based algorithm (RBA) and fine-tuned RadBERT for zero-shot labeling of chest-abdomen-pelvis (CAP) CT reports, and to examine how labeling conventions affect measured performance. Materials and Methods: In this retrospective study, 40,833 CAP CT reports from 29,540 patients examined between 2012 and 2017 were analyzed; age and sex were unavailable. Five LLMs were prompted zero-shot to assign 15 labels across three organ systems and compared with an RBA and fine-tuned RadBERT. Inter-model agreement was assessed with Cohen kappa ($κ$) on 12,197 held-out reports. Macro-averaged F1 was computed against 1,789 radiologist-supervised annotations, the same annotations simplified to disregard clinical actionability, and the CT-RATE dataset. Nonoverlapping bootstrapped 95% CIs indicated relevant differences. Results: MedGemma 27B and MedGemma-1.5 4B showed the highest median agreement ($κ$ = 0.90). Against manual annotations, Gemma-3 27B achieved the highest macro-averaged F1 (0.82 [95% CI: 0.80, 0.83]) versus 0.66 for RadBERT and 0.64 for the RBA; a majority-vote ensemble scored 0.84. Scores were lowest averaged across models for subjective classes, kidney lesion (0.44) and atelectasis (0.67). Relabeling raised F1 for all models on kidney lesion, but for atelectasis only for the LLMs; the RBA and RadBERT declined. F1 against CT-RATE exceeded that against manual annotations for all models, reflecting its more literal convention. Conclusion: Lightweight open-weight LLMs outperformed rule-based and fine-tuned BERT labeling of CAP CT reports with zero-shot prompting. Models and annotators disagreed largely because they applied different labeling criteria.

cs.CL

Virtual Patients, Real Gains: Digital Twin-Based Simulated CT for Multitask Lung Nodule Analysis

AI-based lung cancer screening is constrained by scarce, annotated CT data, particularly for rare nodule presentations. We investigate whether physics-based, anatomy-informed simulated CT can improve AI performance across three lung-nodule tasks: detection, segmentation, and malignancy classification. Using the Virtual Lung Screening Trial framework, we generated 174 digital human twins (XCAT3), embedded 512 procedurally controlled nodules (X-Lesions, 4-30 mm), and simulated CT (DukeSim) under two scanner configurations, yielding 1,044 annotated scans. Combined with clinical data, these trained models for detection (MONAI), segmentation (VISTA3D, nnU-Net), and classification (Med3D), evaluated on external test sets. Detection sensitivity at 1 FP/scan rose from 0.37 to 0.56 (p < 0.001); segmentation improved modestly (Dice 0.61 to 0.64, 0.66 to 0.69); classification AUC rose from 0.78 to 0.87 (p < 0.001). Physics-based virtual imaging trials can help address data scarcity in medical AI.

cs.LG

When Does Synthetic CT Transfer? A Label-Free Donor/Host Diagnostic for Medical Vision-Language Model Routing on Real Lung CT

A synthetic measurement of model competence is useful only if it survives the move to real data, yet the real labels that would verify it are exactly what medical imaging lacks. We ask whether transfer can be predicted in advance, label-free, and answer with a mechanism: on synthetic digital twins, competence that is donor-driven (a property of the transplanted nodule) survives the synthetic to real change of host, while host-driven competence (a property of the surrounding anatomy) need not. We test this on three lung CT vision-language tasks chosen to span that axis, across five public VLMs, four guidance conditions, and seven real datasets. The prediction holds in every case: presence and size orderings transfer (R2 >= 0.96), lobe does not; the split survives leave-source-out calibration, and the diagnostic names that boundary before any real label. TrialCouncil, a training-free council calibrated only on synthetic CT, confirms it by matching the best fixed model exactly where transfer is predicted. The contribution is not the router but the finding that transfer itself is predictable, label-free, from synthetic data alone.

cs.CV

iTRIALSPACE: Programmable Virtual Lesion Trials for Controlled Evaluation of Lung CT Models

We introduce iTRIALSPACE, a programmable evaluation framework for controlled assessment of lung CT models. Standard benchmarks are static retrospective collections that entangle lesion size, lobe prevalence, anatomy, and acquisition context, making it difficult to determine what structurally drives model accuracy. iTRIALSPACE addresses this limitation by composing real clinical CTs and lesion profiles into controlled virtual lesion trials through a four-stage pipeline: multidataset nodule profiling, explicit trial specification, anatomy-aware mask insertion, and ControlNet-conditioned CT synthesis. The framework is built on a unified 54-attribute nodule-profile dataset spanning 13,140 annotated nodules from seven public CT sources and instantiated as 13 trial modes. We evaluate iTRIALSPACE in a 55,469-sample Virtual Lesion Study spanning three medical VLMs, four spatialguidance conditions, and three clinical tasks. Across all 13 modes, the synthetic substrate remains within the real-to-real FID baseline, and synthetic performance rankings transfer strongly to real clinical data ($ρ$ = 0.93, p < 10$^{-15}$). Controlled trial modes expose findings unavailable to fixed-distribution benchmarks, including shortcut-driven size prediction collapse under lobe-equalized sampling and hostto-donor variance ratios of 8.9x and 3.3x in twin-cross analysis. These results position iTRIALSPACE as an auditable evaluation infrastructure for controlled, falsifiable testing beyond static retrospective benchmarks.

cs.CV

Reproducible Benchmarking for Lung Nodule Detection and Malignancy Classification Across Multiple Low-Dose CT Datasets

Evaluation of artificial intelligence (AI) models for low-dose CT lung cancer screening is limited by heterogeneous datasets, annotation standards, and evaluation protocols, making performance difficult to compare and translate across clinical settings. We establish a public, reproducible multi-dataset benchmark for lung nodule detection and nodule-level cancer classification and quantify cross-dataset generalizability. Using the Duke Lung Cancer Screening (DLCS) dataset as a clinically curated development set, we evaluate performance across LUNA16/LIDC-IDRI, NLST-3D, and LUNA25. Detection models trained on DLCS and LUNA16 were evaluated externally on NLST-3D using free-response ROC analysis. For malignancy classification, we compared five strategies: randomly initialized ResNet50, Models Genesis, Med3D, a Foundation Model for Cancer Biomarkers, and a Strategic Warm-Start (ResNet50-SWS) approach pretrained using detection-derived candidate patches stratified by confidence. Performance was summarized using AUC with 95% confidence intervals and DeLong tests. Detection performance varied substantially by training dataset, with DLCS-trained models outperforming LUNA16-trained models on external NLST-3D evaluation (sensitivity at 2 false positives per scan: 0.72 vs. 0.64; p < 0.001). For malignancy classification, ResNet50-SWS achieved AUCs of 0.71 (DLCS), 0.90 (LUNA16), 0.81 (NLST-3D), and 0.80 (LUNA25), consistently matching or exceeding alternative pretraining strategies. These results demonstrate that dataset characteristics strongly influence lung cancer AI performance and highlight the need for transparent, multi-dataset benchmarking.

cs.CV

Tri-Reader: An Open-Access, Multi-Stage AI Pipeline for First-Pass Lung Nodule Annotation in Screening CT

Using multiple open-access models trained on public datasets, we developed Tri-Reader, a comprehensive, freely available pipeline that integrates lung segmentation, nodule detection, and malignancy classification into a unified tri-stage workflow. The pipeline is designed to prioritize sensitivity while reducing the candidate burden for annotators. To ensure accuracy and generalizability across diverse practices, we evaluated Tri-Reader on multiple internal and external datasets as compared with expert annotations and dataset-provided reference standards.

cs.CV

The Utility of the Virtual Imaging Trials Methodology for Objective Characterization of AI Systems and Training Data

Purpose: The credibility of Artificial Intelligence (AI) models for medical imaging continues to be a challenge, affected by the diversity of models, the data used to train the models, and applicability of their combination to produce reproducible results for new data. In this work, we aimed to explore whether emerging Virtual Imaging Trials (VIT) methodologies can provide an objective resource to approach this challenge. Approach: The study was conducted for the case example of COVID-19 diagnosis using clinical and virtual computed tomography (CT) and chest radiography (CXR) processed with convolutional neural networks. Multiple AI models were developed and tested using 3D ResNet-like and 2D EfficientNetv2 architectures across diverse datasets. Results: Model performance was evaluated using the area under the curve (AUC) and the DeLong method for AUC confidence intervals. The models trained on the most diverse datasets showed the highest external testing performance, with AUC values ranging from 0.73-0.76 for CT and 0.70-0.73 for CXR. Internal testing yielded higher AUC values (0.77-0.85 for CT and 0.77-1.0 for CXR), highlighting a substantial drop in performance during external validation, which underscores the importance of diverse and comprehensive training and testing data. Most notably, the VIT approach provided objective assessment of the utility of diverse models and datasets, while offering insight into the influence of dataset characteristics, patient factors, and imaging physics on AI efficacy. Conclusions: The VIT approach enhances model transparency and reliability, offering nuanced insights into the factors driving AI performance and bridging the gap between experimental and clinical settings.

eess.IV

NodMAISI: Nodule-Oriented Medical AI for Synthetic Imaging

Objective: Although medical imaging datasets are increasingly available, abnormal and annotation-intensive findings critical to lung cancer screening, particularly small pulmonary nodules, remain underrepresented and inconsistently curated. Methods: We introduce NodMAISI, an anatomically constrained, nodule-oriented CT synthesis and augmentation framework trained on a unified multi-source cohort (7,042 patients, 8,841 CTs, 14,444 nodules). The framework integrates: (i) a standardized curation and annotation pipeline linking each CT with organ masks and nodule-level annotations, (ii) a ControlNet-conditioned rectified-flow generator built on MAISI-v2's foundational blocks to enforce anatomy- and lesion-consistent synthesis, and (iii) lesion-aware augmentation that perturbs nodule masks (controlled shrinkage) while preserving surrounding anatomy to generate paired CT variants. Results: Across six public test datasets, NodMAISI improved distributional fidelity relative to MAISI-v2 (real-to-synthetic FID range 1.18 to 2.99 vs 1.69 to 5.21). In lesion detectability analysis using a MONAI nodule detector, NodMAISI substantially increased average sensitivity and more closely matched clinical scans (IMD-CT: 0.69 vs 0.39; DLCS24: 0.63 vs 0.20), with the largest gains for sub-centimeter nodules where MAISI-v2 frequently failed to reproduce the conditioned lesion. In downstream nodule-level malignancy classification trained on LUNA25 and externally evaluated on LUNA16, LNDbv4, and DLCS24, NodMAISI augmentation improved AUC by 0.07 to 0.11 at <=20% clinical data and by 0.12 to 0.21 at 10%, consistently narrowing the performance gap under data scarcity.

cs.CV

Demographic Distribution Matching between real world and virtual phantom population

Virtual imaging trials (VITs) offer scalable and cost-effective tools for evaluating imaging systems and protocols. However, their translational impact depends on rigorous comparability between virtual and real-world populations. This study introduces DISTINCT (Distributional Subsampling for Covariate-Targeted Alignment), a statistical framework for selecting demographically aligned subsamples from large clinical datasets to support robust comparisons with virtual cohorts. We applied DISTINCT to the National Lung Screening Trial (NLST) and a companion virtual trial dataset (VLST). The algorithm jointly aligned typical continuous (age, BMI) and categorical (sex, race, ethnicity) variables by constructing multidimensional bins based on discretized covariates. For a given target size, DISTINCT samples individuals to match the joint demographic distribution of the reference population. We evaluated the demographic similarity between VLST and progressively larger NLST subsamples using Wasserstein and Kolmogorov-Smirnov (K-S) distances to identify the maximal subsample size with acceptable alignment. The algorithm identified a maximal aligned NLST subsample of 9,974 participants, preserving demographic similarity to the VLST population. Receiver operating characteristic (ROC) analysis using risk scores for lung cancer detection showed that area under the curve (AUC) estimates stabilized beyond 6,000 participants, confirming the sufficiency of aligned subsamples for virtual imaging trial evaluation. Stratified AUC analysis revealed substantial performance variation across demographic subgroups, reinforcing the importance of covariate alignment in comparative studies.

stat.AP

Virtual Lung Screening Trial (VLST): An In Silico Study Inspired by the National Lung Screening Trial for Lung Cancer Detection

Clinical imaging trials play a crucial role in advancing medical innovation but are often costly, inefficient, and ethically constrained. Virtual Imaging Trials (VITs) present a solution by simulating clinical trial components in a controlled, risk-free environment. The Virtual Lung Screening Trial (VLST), an in silico study inspired by the National Lung Screening Trial (NLST), illustrates the potential of VITs to expedite clinical trials, minimize risks to participants, and promote optimal use of imaging technologies in healthcare. This study aimed to show that a virtual imaging trial platform could investigate some key elements of a major clinical trial, specifically the NLST, which compared Computed tomography (CT) and chest radiography (CXR) for lung cancer screening. With simulated cancerous lung nodules, a virtual patient cohort of 294 subjects was created using XCAT human models. Each virtual patient underwent both CT and CXR imaging, with deep learning models, the AI CT-Reader and AI CXR-Reader, acting as virtual readers to perform recall patients with suspicion of lung cancer. The primary outcome was the difference in diagnostic performance between CT and CXR, measured by the Area Under the Curve (AUC). The AI CT-Reader showed superior diagnostic accuracy, achieving an AUC of 0.92 (95% CI: 0.90-0.95) compared to the AI CXR-Reader's AUC of 0.72 (95% CI: 0.67-0.77). Furthermore, at the same 94% CT sensitivity reported by the NLST, the VLST specificity of 73% was similar to the NLST specificity of 73.4%. This CT performance highlights the potential of VITs to replicate certain aspects of clinical trials effectively, paving the way toward a safe and efficient method for advancing imaging-based diagnostics.

eess.IV

Refining Focus in AI for Lung Cancer: Comparing Lesion-Centric and Chest-Region Models with Performance Insights from Internal and External Validation

Background: AI-based classification models are essential for improving lung cancer diagnosis. However, the relative performance of lesion-level versus chest-region models in internal and external datasets remains unclear. Purpose: This study evaluates the performance of lesion-level and chest-region models for lung cancer classification, comparing their effectiveness across internal Duke Lung Nodule Dataset 2024 (DLND24) and external (LUNA16, NLST) datasets, with a focus on subgroup analyses by demographics, histology, and imaging characteristics. Materials and Methods: Two AI models were trained: one using lesion-centric patches (64,64,64) and the other using chest-region patches (512,512,8). Internal validation was conducted on DLND24, while external validation utilized LUNA16 and NLST datasets. The models performances were assessed using AUC-ROC, with subgroup analyses for demographic, clinical, and imaging factors. Statistical comparisons were performed using DeLongs test. Gradient-based visualizations and probability distribution were further used for analysis. Results: The lesion-level model consistently outperformed the chest-region model across datasets. In internal validation, the lesion-level model achieved an AUC of 0.71(CI: 0.61-0.81), compared to 0.68(0.57-0.77) for the chest-region model. External validation showed similar trends, with AUCs of 0.90(0.87-0.92) and 0.81(0.79-0.82) on LUNA16 and NLST, respectively. Subgroup analyses revealed significant advantages for lesion-level models in certain histological subtypes (adenocarcinoma) and imaging conditions (CT manufacturers). Conclusion: Lesion-level models demonstrate superior classification performance, especially for external datasets and challenging subgroups, suggesting their clinical utility for precision lung cancer diagnostics.

eess.IV

Peritumoral Expansion Radiomics for Improved Lung Cancer Classification

Purpose: This study investigated how nodule segmentation and surrounding peritumoral regions influence radionics-based lung cancer classification. Methods: Using 3D CT scans with bounding box annotated nodules, we generated 3D segmentations using four techniques: Otsu, Fuzzy C-Means (FCM), Gaussian Mixture Model (GMM), and K-Nearest Neighbors (KNN). Radiomics features were extracted using the PyRadiomics library, and multiple machine-learning-based classifiers, including Random Forest, Logistic Regression, and KNN, were employed to classify nodules as cancerous or non-cancerous. The best-performing segmentation and model were further analyzed by expanding the initial nodule segmentation into the peritumoral region (2, 4, 6, 8, 10, and 12 mm) to understand the influence of the surrounding area on classification. Additionally, we compared our results to deep learning-based feature extractors Foundation Model for Cancer Biomarkers (FMCB) and other state-of-the-art baseline models. Results: Incorporating peritumoral regions significantly enhanced performance, with the best result obtained at 8 mm expansion (AUC = 0.78). Compared to image-based deep learning models, such as FMCB (AUC = 0.71) and ResNet50-SWS++ (AUC = 0.71), our radiomics-based approach demonstrated superior classification accuracy. Conclusion: The study highlights the importance of peritumoral expansion in improving lung cancer classification using radiomics. These findings can inform the development of more robust AI-driven diagnostic tools.

eess.IV

XCAT-3.0: A Comprehensive Library of Personalized Digital Twins Derived from CT Scans

Virtual Imaging Trials (VIT) offer a cost-effective and scalable approach for evaluating medical imaging technologies. Computational phantoms, which mimic real patient anatomy and physiology, play a central role in VITs. However, the current libraries of computational phantoms face limitations, particularly in terms of sample size and diversity. Insufficient representation of the population hampers accurate assessment of imaging technologies across different patient groups. Traditionally, the more realistic computational phantoms were created by manual segmentation, which is a laborious and time-consuming task, impeding the expansion of phantom libraries. This study presents a framework for creating realistic computational phantoms using a suite of automatic segmentation models and performing three forms of automated quality control on the segmented organ masks. The result is the release of over 2500 new computational phantoms, so-named XCAT3.0 after the ubiquitous XCAT computational construct. This new formation embodies 140 structures and represents a comprehensive approach to detailed anatomical modeling. The developed computational phantoms are formatted in both voxelized and surface mesh formats. The framework is combined with an in-house CT scanner simulator to produce realistic CT images. The framework has the potential to advance virtual imaging trials, facilitating comprehensive and reliable evaluations of medical imaging technologies. Phantoms may be requested at https://cvit.duke.edu/resources/. Code, model weights, and sample CT images are available at https://xcat-3.github.io/.

eess.IV

What limits performance of weakly supervised deep learning for chest CT classification?

Weakly supervised learning with noisy data has drawn attention in the medical imaging community due to the sparsity of high-quality disease labels. However, little is known about the limitations of such weakly supervised learning and the effect of these constraints on disease classification performance. In this paper, we test the effects of such weak supervision by examining model tolerance for three conditions. First, we examined model tolerance for noisy data by incrementally increasing error in the labels within the training data. Second, we assessed the impact of dataset size by varying the amount of training data. Third, we compared performance differences between binary and multi-label classification. Results demonstrated that the model could endure up to 10% added label error before experiencing a decline in disease classification performance. Disease classification performance steadily rose as the amount of training data was increased for all disease classes, before experiencing a plateau in performance at 75% of training data. Last, the binary model outperformed the multilabel model in every disease category. However, such interpretations may be misleading, as the binary model was heavily influenced by co-occurring diseases and may not have learned the specific features of the disease in the image. In conclusion, this study may help the medical imaging community understand the benefits and risks of weak supervision with noisy labels. Such studies demonstrate the need to build diverse, large-scale datasets and to develop explainable and responsible AI.

eess.IV

Multi-Label Annotation of Chest Abdomen Pelvis Computed Tomography Text Reports Using Deep Learning

Purpose: To develop high throughput multi-label annotators for body (chest, abdomen, and pelvis) Computed Tomography (CT) reports that can be applied across a variety of abnormalities, organs, and disease states. Approach: We used a dictionary approach to develop rule-based algorithms (RBA) for extraction of disease labels from radiology text reports. We targeted three organ systems (lungs/pleura, liver/gallbladder, kidneys/ureters) with four diseases per system based on their prevalence in our dataset. To expand the algorithms beyond pre-defined keywords, attention-guided recurrent neural networks (RNN) were trained using the RBA-extracted labels to classify reports as being positive for one or more diseases or normal for each organ system. Confounding effects on model performance were evaluated using random initialization or pre-trained embedding as well as different sizes of training datasets. Performance was evaluated using the receiver operating characteristic (ROC) area under the curve (AUC) against 2,158 manually obtained labels. Results: Our models extracted disease labels from 261,229 radiology reports of 112,501 unique subjects. Pre-trained models outperformed random initialization across all diseases. As the training dataset size was reduced, performance was robust except for a few diseases with relatively small number of cases. Pre-trained classification AUCs achieved > 0.95 for all five disease outcomes across all three organ systems. Conclusions: Our label-extracting pipeline was able to encompass a variety of cases and diseases by generalizing beyond strict rules with exceptional accuracy. This method can be easily adapted to enable automated labeling of hospital-scale medical data sets for training image-based disease classifiers.

cs.AI

Virtual vs. Reality: External Validation of COVID-19 Classifiers using XCAT Phantoms for Chest Computed Tomography

Research studies of artificial intelligence models in medical imaging have been hampered by poor generalization. This problem has been especially concerning over the last year with numerous applications of deep learning for COVID-19 diagnosis. Virtual imaging trials (VITs) could provide a solution for objective evaluation of these models. In this work utilizing the VITs, we created the CVIT-COVID dataset including 180 virtually imaged computed tomography (CT) images from simulated COVID-19 and normal phantom models under different COVID-19 morphology and imaging properties. We evaluated the performance of an open-source, deep-learning model from the University of Waterloo trained with multi-institutional data and an in-house model trained with the open clinical dataset called MosMed. We further validated the model's performance against open clinical data of 305 CT images to understand virtual vs. real clinical data performance. The open-source model was published with nearly perfect performance on the original Waterloo dataset but showed a consistent performance drop in external testing on another clinical dataset (AUC=0.77) and our simulated CVIT-COVID dataset (AUC=0.55). The in-house model achieved an AUC of 0.87 while testing on the internal test set (MosMed test set). However, performance dropped to an AUC of 0.65 and 0.69 when evaluated on clinical and our simulated CVIT-COVID dataset. The VIT framework offered control over imaging conditions, allowing us to show there was no change in performance as CT exposure was changed from 28.5 to 57 mAs. The VIT framework also provided voxel-level ground truth, revealing that performance of in-house model was much higher at AUC=0.87 for diffuse COVID-19 infection size >2.65% lung volume versus AUC=0.52 for focal disease with <2.65% volume. The virtual imaging framework enabled these uniquely rigorous analyses of model performance.

eess.IV

Quality or Quantity: Toward a Unified Approach for Multi-organ Segmentation in Body CT

Organ segmentation of medical images is a key step in virtual imaging trials. However, organ segmentation datasets are limited in terms of quality (because labels cover only a few organs) and quantity (since case numbers are limited). In this study, we explored the tradeoffs between quality and quantity. Our goal is to create a unified approach for multi-organ segmentation of body CT, which will facilitate the creation of large numbers of accurate virtual phantoms. Initially, we compared two segmentation architectures, 3D-Unet and DenseVNet, which were trained using XCAT data that is fully labeled with 22 organs, and chose the 3D-Unet as the better performing model. We used the XCAT-trained model to generate pseudo-labels for the CT-ORG dataset that has only 7 organs segmented. We performed two experiments: First, we trained 3D-UNet model on the XCAT dataset, representing quality data, and tested it on both XCAT and CT-ORG datasets. Second, we trained 3D-UNet after including the CT-ORG dataset into the training set to have more quantity. Performance improved for segmentation in the organs where we have true labels in both datasets and degraded when relying on pseudo-labels. When organs were labeled in both datasets, Exp-2 improved Average DSC in XCAT and CT-ORG by 1. This demonstrates that quality data is the key to improving the model's performance.

eess.IV