Searcharxiv⌕ Search

arXiv subjects

Farid Ya. Khalili

Publications and source records attributed to Farid Ya. Khalili.

25 records · Page 2Linked to original sources

QND measurements for future gravitational-wave detectors

Second-generation interferometric gravitational-wave detectors will be operating at the Standard Quantum Limit, a sensitivity limitation set by the trade off between measurement accuracy and quantum back action, which is governed by the Heisenberg Uncertainty Principle. We review several schemes that allows the quantum noise of interferometers to surpass the Standard Quantum Limit significantly over a broad frequency band. Such schemes may be an important component of the design of third-generation detectors.

gr-qc↗

Quantum noise of a Michelson-Sagnac interferometer with translucent mechanical oscillator

Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes with high mechanical Q-values at room temperature have attracted attention as low thermal noise mechanical oscillators. However, the power reflectance of these membranes is much lower than unity which makes the use of advanced interferometer recycling techniques to amplify the radiation pressure noise in a standard Michelson interferometer inefficient. Here, we propose and theoretically analyze a Michelson-Sagnac interferometer that includes the membrane as a common end mirror for the Michelson interferometer part. In this new topology, both, power- and signal-recycling can be used even if the reflectance of the membrane is much lower than unity. In particular, signal-recycling is a useful tool because it does not involve a power increase at the membrane. We derive the formulas for the quantum radiation pressure noise and the shot-noise of an oscillator position measurement and compare them with theoretical models of the thermal noise of a SiN membrane with a fundamental resonant frequency of 75 kHz and an effective mass of 125 ng. We find that quantum radiation pressure noise should be observable with a power of 1 W at the central beam splitter of the interferometer and a membrane temperature of 1 K.

quant-ph↗

Increasing the sensitivity of future gravitational-wave detectors with double squeezed-input

We consider improving the sensitivity of future interferometric gravitational-wave detectors by simultaneously injecting two squeezed vacuums (light), filtered through a resonant Fabry-Perot cavity, into the dark port of the interferometer.The same scheme with single squeezed vacuum was first proposed and analyzed by Corbitt et al. Here we show that the extra squeezed vacuum, together with an additional homodyne detection suggested previously by one of the authors, allows reduction of quantum noise over the entire detection band. To motivate future implementations, we take into account a realistic technical noise budget for Advanced LIGO (AdvLIGO) and numerically optimize the parameters of both the filter and the interferometer for detecting gravitational-wave signals from two important astrophysics sources, namely Neutron-Star--Neutron-Star (NSNS) binaries and Bursts. Assuming the optical loss of the 30m filter cavity to be 10ppm per bounce and 10dB squeezing injection, the corresponding quantum noise with optimal parameters lowers by a factor of 10 at high frequencies and goes below the technical noise at low and intermediate frequencies.

gr-qc↗

The noise in gravitational-wave detectors and other classical-force measurements is not influenced by test-mass quantization

It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output (the photon number flux N(t) entering the final photodetector) commutes with itself at different times in the Heisenberg Picture, [N(t), N(t')] = 0, and thus can be regarded as classical. (ii) This number flux is linear in the test-mass initial position and momentum operators x_o and p_o, and those operators influence the measured photon flux N(t) in manners that can easily be removed by filtering -- e.g., in most interferometers, by discarding data near the test masses' 1 Hz swinging freqency. The test-mass operators x_o and p_o contained in the unfiltered output N(t) make a nonzero contribution to the commutator [N(t), N(t')]. That contribution is cancelled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in N(t). This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations. These conclusions are true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that are free from the complexities of real measuring systems.

gr-qc↗

Energetic Quantum Limit in Large-Scale Interferometers

For each optical topology of an interferometric gravitational wave detector, quantum mechanics dictates a minimum optical power (the ``energetic quantum limit'') to achieve a given sensitivity. For standard topologies, when one seeks to beat the standard quantum limit by a substantial factor, the energetic quantum limit becomes impossibly large. Intracavity readout schemes may do so with manageable optical powers.

gr-qc↗

Dual-Resonator Speed Meter for a Free Test Mass

A description and analysis are given of a ``speed meter'' for monitoring a classical force that acts on a test mass. This speed meter is based on two microwave resonators (``dual resonators''), one of which couples evanescently to the position of the test mass. The sloshing of the resulting signal between the resonators, and a wise choice of where to place the resonators' output waveguide, produce a signal in the waveguide that (for sufficiently low frequencies) is proportional to the test-mass velocity (speed) rather than its position. This permits the speed meter to achieve force-measurement sensitivities better than the standard quantum limit (SQL), both when operating in a narrow-band mode and a wide-band mode. A scrutiny of experimental issues shows that it is feasible, with current technology, to construct a demonstration speed meter that beats the wide-band SQL by a factor 2. A concept is sketched for an adaptation of this speed meter to optical frequencies; this adaptation forms the basis for a possible LIGO-III interferometer that could beat the gravitational-wave standard quantum limit h_SQL, but perhaps only by a factor 1/xi = h_SQL/h ~ 3 (constrained by losses in the optics) and at the price of a very high circulating optical power --- larger by 1/xi^2 than that required to reach the SQL.

gr-qc↗

Quantum limits and symphotonic states in free-mass gravitational-wave antennae

Quantum mechanics sets severe limits on the sensitivity and required circulating energy in traditional free-mass gravitational-wave antennas. One possible way to avoid these restrictions is the use of intracavity QND measurements. We analyze a new QND observable, which possesses a number of features that make it a promising candidate for such measurements and propose a practical scheme for the realization of this measurement. In combination with an advanced coordinate meter, this scheme makes it possible to lower substantially the requirements on the circulating power.

quant-ph↗