SearcharxivSearch

arXiv subjects

Farshid Manoocheri

Publications and source records attributed to Farshid Manoocheri.

3 recordsLinked to original sources

Characterization of Predictable Quantum Efficient Detector over a wide range of incident optical power and wavelength

We investigate the Predictable Quantum Efficient Detector (PQED) in the visible and near-infrared wavelength range. The PQED consists of two n-type induced junction photodiodes with $Al_2O_3$ entrance window. Measurements are performed at the wavelengths of 488 nm and 785 nm with incident power levels ranging from 100 $μ$W to 1000 $μ$W. A new way of presenting the normalized photocurrents on a logarithmic scale as a function of bias voltage reveals two distinct negative slope regions and allows direct comparison of charge carrier losses at different wavelengths. The comparison indicates mechanisms that can be understood on the basis of different penetration depths at different wavelengths (0.77 $μ$m at 488 nm and 10.2 $μ$m at 785 nm). The difference in the penetration depths leads also to larger difference in the charge-carrier losses at low bias voltages than at high voltages due to the voltage dependence of the depletion region.

physics.optics

LED based photoacoustic NO$_2$ sensor with sub-ppb detection limit

A high-sensitivity LED based photoacoustic NO$_2$ sensor is demonstrated. Sensitive photoacoustic gas sensors based on incoherent light sources are typically limited by background noise and drifts due to a strong signal generated by light absorbed at the photoacoustic cell walls. Here we reach a sub-ppb detection limit and excellent stability by using cantilever-enhanced photoacoustic detection and performing a two-channel relative measurement. A white-light LED is used as a light source and the spectrum is divided into two wavelength channels with a dichroic filter. The photoacoustic signals generated by the two wavelength channels are measured simultaneously and used to solve the NO$_2$ concentration. The background signal is highly correlated between the two channels and its variations are suppressed in the relative measurement. A noise level below 1 ppb is reached with an averaging time of 70 s. This is, to the best of our knowledge, the first time a sub-ppb detection limit is demonstrated with an LED based photoacoustic NO$_2$ sensor. As LEDs are available at wide selection of emission wavelengths, the results show great potential for development of cost-effective and sensitive detectors for a variety of other trace gasses as well.

physics.ins-det

Electromagnetic Radiation Detection with Broad Spectral Sensitivity and Large Dynamic Range using Cantilever-based Photoacoustic Effect

A sensitive photoacoustic detection approach employing a silicon cantilever is investigated for power measurement of electromagnetic radiation. The technique which is actuated by pressure waves generated through radiation-induced heat, depicts high sensitivity for a considerably large spectral range from 325 nm to 1523 nm. The implemented method shows linear response in the measurement of radiation power from 15 nW to 6 mW, demonstrating a dynamic range of almost six orders of magnitude. A numerical model has been developed to analyse and optimise the measurement sensitivity using different dimensions of the cantilever which is one of the key components of the detection process. The numerical results are in good agreement with the experimentally obtained frequency response of the detection process. The power detection technique shows potential of finding future applications in the technologies that employ electromagnetic radiation detection for scientific studies and industrial purposes.

physics.ins-det