SearcharxivSearch

arXiv subjects

Felipe Ocampo Osorio

Publications and source records attributed to Felipe Ocampo Osorio.

4 recordsLinked to original sources

ModaLens: Measuring Image Sensitivity in Report-Conditioned Medical VLMs

A radiology report can already answer a clinical question, so it is hard to tell whether a vision-language model also uses the image. ModaLens, a paired image-swap audit, measures how report availability changes image sensitivity: MedGemma-27B on 3,199 paired MIMIC-CXR cases from 293 patients, all 14 questions per case (13 finding-specific and one composite), each image replaced by one from another study, usually of the same patient, with question and report fixed. Under an explicit answer instruction, the model's generated answer changes on 4.26 percent of trials with the report and 20.94 percent without it, a paired increase of 16.7 points (patient-clustered 95 percent CI 15.6 to 17.7), so report availability reduces image-swap sensitivity under this protocol; the original prompt with a lowercase first-token readout gives 4.70 percent against 17.07 percent, and substitutions also move continuous answer scores where the binary prediction does not change. The labels are derived from reports, which limits conclusions about visual correctness; the direction replicates in two further model lineages. Code, the exact prompts and a run record for every number are at https://github.com/criticaldata/MODALENS.

cs.CV

Towards a Deterministic Math Solver for Clinical Language Models

Large language models are unreliable at arithmetic, which is a problem for clinical calculators where a single numerical error changes the recommendation. The standard response is to hardcode each calculator as a validated function, one at a time. We test an alternative: the model does not calculate. Instead, it writes case-specific Python that a restricted local executor runs as a deterministic solver, and the model's task reduces to deciding how to use it. We evaluate this Program-Solve interface on MedCalc-Bench Verified (1,100 cases, 55 calculators) against direct model arithmetic and a hand-written 22-calculator library, using Qwen2.5-7B and Qwen2.5-32B-AWQ, after auditing the benchmark's formulas against current clinical guidelines and flagging 16 of 55 with version, use or coefficient concerns. With formulas and gold variables supplied and both routes reading the whole note, handing off to the solver is not a reliable advantage at 7B (75.31% against 72.02%, a paired +3.29 points with a 95% calculator-cluster interval of [-3.49, 10.38]) but is one at 32B (90.53% against 83.47%, +7.05 [0.47, 14.60], clear of zero). The hand-written library is exact on its 440 supported cases but abstains elsewhere (40.0% overall). Adding an executor thus helps some open-weight models more than others even under matched formula, variable and note access, and is not a substitute for verified formulas or reliable variable extraction either way.

cs.AI

Agents Catching Agents: Shortcut Cascades and Benchmark Gaming in Clinical Multi-Agent Systems

Clinical decision support is moving toward committees of language-model agents deliberating on a shared workspace. We ask whether such committees can be gamed by shortcuts, cues a benchmark rewards but a clinician would ignore. Across seven cohorts on six public datasets spanning text (MedQA-USMLE, MedMCQA, MIMIC-CXR reports), imaging (NIH ChestX-ray14, MIMIC-CXR-JPG, CheXpert) and tabular ICU records (SUPPORT2), Gemini committees resist these cues in isolation (flip 5-16%), yet a socially plausible shortcut spreads: when two peers assert the same wrong answer, the holdout under test adopts it in 38% of cases, as does a false "pre-screen" system flag, on both capability tiers. Of three oversight agents, a gate cannot separate adoption from honest agreement (false-positive rate 100%); a same-lineage judge reading only the transcript flags adoption on text (precision 100%, recall 93%) but collapses onto the gate in imaging; a referee that privately re-queries the holdout transfers to imaging (77-88% precision, 13-21% false-positive rate). Tripling a cue's visual salience does not move contagion, whereas a second peer voice raises it by half again. Gaming a hidden rubric is near-silent: only 1/10 text and 1/134 imaging drifters name the rubric they moved toward. What games a committee is social plausibility, and only a referee independent of self-report catches it. Code: https://github.com/criticaldata/benchmaxxing

cs.AI

Quantum Kernel Advantage over Classical Collapse in Medical Foundation Model Embeddings

We provide evidence of quantum kernel advantage under noiseless simulation in binary insurance classification on MIMIC-CXR chest radiographs using quantum support vector machines (QSVM) with frozen embeddings from three medical foundation models (MedSigLIP-448, RAD-DINO, ViT-patch32). We propose a two-tier fair comparison framework in which both classifiers receive identical PCA-q features. At Tier 1 (untuned QSVM vs. untuned linear SVM, C = 1 both sides), QSVM wins minority-class F1 in all 18 tested configurations (17 at p < 0.001, 1 at p < 0.01). The classical linear kernel collapses to majority-class prediction on 90-100% of seeds at every qubit count, while QSVM maintains non-trivial recall. At q = 11 (MedSigLIP-448 plateau center), QSVM achieves mean F1 = 0.343 vs. classical F1 = 0.050 (F1 gain = +0.293, p < 0.001) without hyperparameter tuning. Under Tier 2 (untuned QSVM vs. C-tuned RBF SVM), QSVM wins all seven tested configurations (mean gain +0.068, max +0.112). Eigenspectrum analysis reveals quantum kernel effective rank reaches 69.80 at q = 11, far exceeding linear kernel rank, while classical collapse remains C-invariant. A full qubit sweep reveals architecture-dependent concentration onset across models. Code: https://github.com/sebasmos/qml-medimage

quant-ph