Searcharxiv⌕ Search

arXiv subjects

Felix Hofmann

Publications and source records attributed to Felix Hofmann.

At least 55 records · Page 3Linked to original sources

Thermal diffusivity degradation and point defect density in self-ion implanted tungsten

Using transient grating spectroscopy (TGS) we measure the thermal diffusivity of tungsten exposed to different levels of 20 MeV self-ion irradiation. Damage as low as 3.2 x 10^-4 displacements per atom (dpa) causes a measurable reduction in thermal diffusivity. Doses of 0.1 dpa and above, up to 10 dpa, give a degradation of around 55% from the pristine value at room temperature. Using a kinetic theory model, the density of irradiation-induced point defects is estimated based on the measured changes in thermal diffusivity as a function of dose. These predictions are compared with point defect and dislocation loop densities observed in transmission electron microscopy (TEM). Molecular dynamics (MD) predictions are combined with the TEM observations to estimate the density of point defects associated with defect clusters too small to be probed by TEM. When these "invisible" defects are accounted for, the total point defect density agrees well with that estimated from TGS for a range of doses spanning 3 orders of magnitude. Kinetic theory modelling is also used to estimate the thermal diffusivity degradation expected due to TEM-visible and invisible defects. Finely distributed invisible defects appear to play a much more important role in the thermal diffusivity reduction than larger TEM-visible dislocation loops. This work demonstrates the capability of TGS, in conjunction with kinetic theory models, to provide rapid, quantitative insight into defect densities and property evolution in irradiated materials.

cond-mat.mtrl-sci↗

Non-contact, non-destructive mapping of thermal diffusivity and surface acoustic wave speed using transient grating spectroscopy

We present new developments of the laser-induced transient grating spectroscopy (TGS) technique that enable the measurement of large area 2D maps of thermal diffusivity and surface acoustic wave speed. Additional capabilities include targeted measurements and the ability to accommodate samples with increased surface roughness. These new capabilities are demonstrated by recording large TGS maps of deuterium implanted tungsten, linear friction welded aerospace alloys and high entropy alloys with a range of grain sizes. The results illustrate the ability to view grain microstructure in elastically anisotropic samples, and to detect anomalies in samples, for example due to irradiation and previous measurements. They also point to the possibility of using TGS to quantify grain size at the surface of polycrystalline materials.

physics.app-ph↗

Hardening and Strain Localisation in Helium-Ion-Implanted Tungsten

Tungsten is the main candidate material for plasma-facing armour components in future fusion reactors. In-service, fusion neutron irradiation creates lattice defects through collision cascades. Helium, injected from plasma, aggravates damage by increasing defect retention. Both can be mimicked using helium-ion-implantation. In a recent study on 3000 appm helium-implanted tungsten (W-3000He), we hypothesized helium-induced irradiation hardening, followed by softening during deformation. The hypothesis was founded on observations of large increase in hardness, substantial pile-up and slip-step formation around nano-indents and Laue diffraction measurements of localised deformation underlying indents. Here we test this hypothesis by implementing it in a crystal plasticity finite element (CPFE) formulation, simulating nano-indentation in W-3000He at 300 K. The model considers thermally-activated dislocation glide through helium-defect obstacles, whose barrier strength is derived as a function of defect concentration and morphology. Only one fitting parameter is used for the simulated helium-implanted tungsten; defect removal rate. The simulation captures the localised large pile-up remarkably well and predicts confined fields of lattice distortions and geometrically necessary dislocation underlying indents which agree quantitatively with previous Laue measurements. Strain localisation is further confirmed through high resolution electron backscatter diffraction and transmission electron microscopy measurements on cross-section lift-outs from centre of nano-indents in W-3000He.

cond-mat.mtrl-sci↗

Nano-scale imaging of the full strain tensor of specific dislocations extracted from a bulk sample

Lattice defects play a key role in determining the properties of crystalline materials. Probing the 3D lattice strains that govern their interactions remains a challenge. Bragg Coherent Diffraction Imaging (BCDI) allows strain to be measured with nano-scale 3D resolution. However, it is currently limited to materials that form micro-crystals. Here we introduce a new technique that allows the manufacture of BCDI samples from bulk materials. Using tungsten as an example, we show that focussed ion beam (FIB) machining can be used to extract, from macroscopic crystals, micron-sized BCDI samples containing specific pre-selected defects. To interpret the experimental data, we develop a new displacement-gradient-based analysis for multi-reflection BCDI. This allows accurate recovery of the full lattice strain tensor from samples containing multiple dislocations. These new capabilities open the door to BCDI as a microscopy tool for studying complex real-world materials.

cond-mat.mtrl-sci↗

Dislocation density distribution at slip band-grain boundary intersections

We study the mechanisms of slip transfer at a grain boundary, in titanium, using Differential Aperture X-ray Laue Micro-diffraction (DAXM). This 3D characterization tool enables measurement of the full (9-component) Nye lattice curvature tensor and calculation of the density of geometrically necessary dislocations (GNDs). We observe dislocation pile-ups at a grain boundary, as the neighbor grain prohibits easy passage for dislocation transmission. This incompatibility results in local micro-plasticity within the slipping grain, near to where the slip planes intersect the grain boundary, and we observe bands of GNDs lying near the grain boundary. We observe that the distribution of GNDs can be significantly influenced by the formation of grain boundary ledges that serve as secondary dislocation sources. This observation highlights the non-continuum nature of polycrystal deformation and helps us understand the higher order complexity of grain boundary characteristics.

cond-mat.mtrl-sci↗

Transient grating spectroscopy of thermal diffusivity degradation in deuterium implanted tungsten

Using transient grating spectroscopy, we measure thermal diffusivity and surface acoustic wave speed in tungsten exposed to different fluences of deuterium plasma. Scanning electron microscopy (SEM) shows the formation of surface blisters that have similar morphology for all fluences. A significant reduction in thermal diffusivity and surface acoustic wave speed occurs as a result of plasma exposure. A saturation of the thermal diffusivity reduction with fluence is seen. Deuterium ion flux density appears play a more important role in the thermal diffusivity reduction than the fluence. These results have important implications for plasma facing components in future fusion reactors.

cond-mat.mtrl-sci↗

Surface terraces in pure tungsten formed by high-temperature oxidation

We observe large-scale surface terraces in tungsten oxidised at high temperature and in high vacuum. Their formation is highly dependent on crystal orientation, with only {111} grains showing prominent terraces. Terrace facets are aligned with {100} crystallographic planes, leading to an increase in total surface energy, making a diffusion-driven formation mechanism unlikely. Instead we hypothesize that preferential oxidation of {100} crystal planes controls terrace formation. Grain height profiles after oxidation and the morphology of samples heat treated with limited oxygen supply are consistent with this hypothesis. Our observations have important implications for the use of tungsten in extreme environments.

cond-mat.mtrl-sci↗

Transient grating spectroscopy: An ultrarapid, nondestructive materials evaluation technique

Structure-property relationships are the foundation of materials science. Linking microstructure and material properties is essential for predicting material response to driving forces, managing in-service material degradation, and engineering materials for optimal performance. Elastic, thermal, and acoustic properties provide a convenient gateway to directly or indirectly probe material structure across multiple length scales. We review how using the laser-induced transient grating spectroscopy (TGS) technique, which uses a transient diffraction grating to generate surface acoustic waves (SAWs) and temperature gratings on a material surface, non-destructively reveals the material elasticity, thermal diffusivity, and energy dissipation on the sub-microsecond timescale, within a tunable sub-surface depth. This technique has already been applied to many challenging problems in materials characterization, from analysis of radiation damage, to colloidal crystals, to phonon-mediated thermal transport in nanostructured systems, to crystal orientation and lattice parameter determination. Examples of these applications, as well as inferring aspects of microstructural evolution, illustrate the wide potential reach of TGS to solve old materials challenges, and to uncover new science. We conclude by looking ahead at the tremendous potential of TGS for materials discovery and optimization when applied in situ to dynamically evolving systems.

physics.app-ph↗

Orientation-dependent indentation response of helium-implanted tungsten

A literature review of studies investigating the topography of nano-indents in ion-implanted materials reveals seemingly inconsistent observations, with report of both pile-up and sink-in. This may be due to the crystallographic orientation of the measured sample point, which is often not considered when evaluating implantation-induced changes in the deformation response. Here we explore the orientation dependence of spherical nano-indentation in pure and helium-implanted tungsten, considering grains with <001>, <110> and <111> out-of-plane orientations. Atomic force microscopy (AFM) of indents in unimplanted tungsten shows little orientation dependence. However, in the implanted material a much larger, more localised pile-up is observed for <001> grains than for <110> and <111> orientations. Based on the observations for <001> grains, we hypothesise that a large initial hardening due to helium-induced defects is followed by localised defect removal and subsequent strain softening. A crystal plasticity finite element model of the indentation process, formulated based on this hypothesis, accurately reproduces the experimentally-observed orientation-dependence of indent morphology. The results suggest that the mechanism governing the interaction of helium-induced defects with glide dislocations is orientation independent. Rather, differences in pile-up morphology are due to the relative orientations of the crystal slip systems, sample surface and spherical indenter. This highlights the importance of accounting for crystallographic orientation when probing the deformation behaviour of ion-implanted materials using nano-indentation.

physics.app-ph↗

Helium-Implantation-Induced Lattice Strains and Defects in Tungsten probed by X-ray Micro-diffraction

Tungsten is the main candidate material for plasma-facing armour components in future fusion reactors. Bombardment with energetic fusion neutrons causes collision cascade damage and defect formation. Interaction of defects with helium, produced by transmutation and injected from the plasma, modifies defect retention and behaviour. Here we investigate the residual lattice strains caused by different doses of helium-ion-implantation into tungsten and tungsten-rhenium alloys. Energy and depth-resolved synchrotron X-ray micro-diffraction uniquely permits the measurement of lattice strain with sub-micron 3D spatial resolution and ~10-4 strain sensitivity. Increase of helium dose from 300 appm to 3000 appm increases volumetric strain by only ~2.4 times, indicating that defect retention per injected helium atom is ~3 times higher at low helium doses. This suggests that defect retention is not a simple function of implanted helium dose, but strongly depends on material composition and presence of impurities. Conversely, analysis of W-1wt% Re alloy samples and of different crystal orientations shows that both the presence of rhenium, and crystal orientation, have comparatively small effect on defect retention. These insights are key for the design of armour components in future reactors where it will be essential to account for irradiation-induced dimensional change when predicting component lifetime and performance.

cond-mat.mtrl-sci↗

Mapping the full lattice strain tensor of a single dislocation by High Angular Resolution Transmission Kikuchi Diffraction (HR-TKD)

The full lattice strain tensor and lattice rotations induced by a dislocation in pure tungsten were mapped using high-resolution transmission Kikuchi diffraction (HR-TKD) in a SEM. The HR-TKD measurement agrees very well with a forward calculation using an elastically isotropic model of the dislocation and its Burgers vector. Our results demonstrate that the spatial and angular resolution of HR-TKD in SEM is sufficiently high to resolve the details of lattice distortions near individual dislocations. This capability opens a number of new interesting opportunities, for example determining the Burgers vector of an unknown dislocation in a fast and straightforward way.

cond-mat.mtrl-sci↗

Consistent determination of geometrically necessary dislocation density from simulations and experiments

The use of Nye's dislocation tensor for calculating the density of geometrically necessary dislocations (GND) is widely adopted in the study of plastically deformed materials. The curl operation involved in finding the Nye tensor, while conceptually straightforward has been marred with inconsistencies and several different definitions are in use. For the three most common definitions, we show that their consistent application leads to the same result. To eliminate frequently encountered confusion, a summary of expressions for Nye's tensor in terms of elastic and plastic deformation gradient, and for both small and large deformations, is presented. A further question when estimating GND density concerns the optimization technique used to solve the under-determined set of equations linking Nye's tensor and GND density. A systematic comparison of the densities obtained by two widely used techniques, L1 and L2 minimisation, shows that both methods yield remarkably similar total GND densities. Thus the mathematically simpler, L2, may be preferred over L1 except when information about the distribution of densities on specific slip systems is required. To illustrate this, we compare experimentally measured lattice distortions beneath nano-indents in pure tungsten, probed using 3D-resolved synchrotron X-ray micro-diffraction, with those predicted by 3D strain-gradient crystal plasticity finite element calculations. The results are in good agreement and show that the volumetric component of the elastic strain field has a surprisingly small effect on the determined Nye tensor. This is important for experimental techniques, such as micro-beam Laue measurements and HR-EBSD, where only the deviatoric strain component is measured.

cond-mat.mtrl-sci↗

3D reconstruction of the spatial distribution of dislocation loops using a triangulation approach

We propose a new approach for reconstructing the 3D spatial distribution of small dislocation loops (DLs) from 2D TEM micrographs. This method is demonstrated for small DLs in tungsten, formed by low-dose ion-implantation, that appear as circular spots in diffraction contrast images. To extract the 3D position of specific DLs, their 2D position in multiple weak-beam dark-field TEM micrographs, recorded at different tilt angles, is fitted. From this fit the geometric centre and size of each DL in each micrograph can be extracted. Using a forward prediction approach each specific DL is identified in all the 2D projections. A system of linear equations can then be setup, linking the 3D position of each DL to its 2D position in each projection. If more than 2 projections are available this system of equations is over-determined, and the 3D position of each DL is found by least-squares fitting. The results are in good agreement with the damage microstructure recovered using a generalized weighted back-projection method. Importantly the triangulation approach requires fewer projections and is less sensitive to the angular range covered by the projections. Our new method is also less sensitive to contrast variations due to local deviations from the diffraction condition. These advantages, as well as the accuracy of the triangulation method, are discussed in detail.

cond-mat.mtrl-sci↗

Glancing-Incidence Focussed Ion Beam Milling: A Coherent X-ray Diffraction Study of 3D Nano-scale Lattice Strains and Crystal Defects

This study presents a detailed examination of the lattice distortions introduced by glancing incidence Focussed Ion Beam (FIB) milling. Using non-destructive multi-reflection Bragg coherent X-ray diffraction we probe damage formation in an initially pristine gold micro-crystal following several stages of FIB milling. These experiments allow access to the full lattice strain tensor in the micro-crystal with ~25 nm 3D spatial resolution, enabling a nano-scale analysis of residual lattice strains and defects formed. Our results show that 30 keV glancing incidence milling produces fewer large defects than normal incidence milling at the same energy. However the resulting residual lattice strains have similar magnitude and extend up to ~50 nm into the sample. At the edges of the milled surface, where the ion-beam tails impact the sample at near-normal incidence, large dislocation loops with a range of burgers vectors are formed. Further glancing incidence FIB polishing with 5 keV ion energy removes these dislocation loops and reduces the lattice strains caused by higher energy FIB milling. However, even at the lower ion energy, damage-induced lattice strains are present within a ~20 nm thick surface layer. These results highlight the need for careful consideration and management of FIB damage. They also show that low-energy FIB-milling is an effective tool for removing FIB-milling induced lattice strains. This is important for the preparation of micro-mechanical test specimens and strain microscopy samples.

cond-mat.mtrl-sci↗

Automatic Liver and Tumor Segmentation of CT and MRI Volumes using Cascaded Fully Convolutional Neural Networks

Automatic segmentation of the liver and hepatic lesions is an important step towards deriving quantitative biomarkers for accurate clinical diagnosis and computer-aided decision support systems. This paper presents a method to automatically segment liver and lesions in CT and MRI abdomen images using cascaded fully convolutional neural networks (CFCNs) enabling the segmentation of a large-scale medical trial or quantitative image analysis. We train and cascade two FCNs for a combined segmentation of the liver and its lesions. In the first step, we train a FCN to segment the liver as ROI input for a second FCN. The second FCN solely segments lesions within the predicted liver ROIs of step 1. CFCN models were trained on an abdominal CT dataset comprising 100 hepatic tumor volumes. Validations on further datasets show that CFCN-based semantic liver and lesion segmentation achieves Dice scores over 94% for liver with computation times below 100s per volume. We further experimentally demonstrate the robustness of the proposed method on an 38 MRI liver tumor volumes and the public 3DIRCAD dataset.

cs.CV↗

Spectral focusing of broadband silver electroluminescence in nanoscopic FRET-LEDs

Few inventions have shaped the world like the incandescent bulb. While Edison used thermal radiation from ohmically heated conductors, some noble metals exhibit "cold" electroluminescence (EL) in percolation films, tunnel diodes, electromigrated nanoparticle aggregates, optical antennae, or scanning-tunnelling microscopy (STM). The origin of this radiation, which is spectrally broad and depends on applied bias, is controversial given the low radiative yields of electronic transitions. Nanoparticle EL is particularly intriguing since it involves localized surface-plasmon resonances with large dipole moments. Such plasmons enable very efficient non-radiative fluorescence resonance energy transfer (FRET) coupling to proximal resonant dipole transitions. We demonstrate nanoscopic FRET-LEDs which exploit the opposite process, energy transfer from silver nanoparticles to exfoliated monolayers of transition-metal dichalcogenides (TMDCs). In diffraction-limited hotspots showing pronounced photon bunching, broadband silver EL is focused into the narrow excitonic resonance of the atomically thin overlayer. Such devices may offer alternatives to conventional nano-LEDs in on-chip optical interconnects.

physics.optics↗

Automatic Liver and Lesion Segmentation in CT Using Cascaded Fully Convolutional Neural Networks and 3D Conditional Random Fields

Automatic segmentation of the liver and its lesion is an important step towards deriving quantitative biomarkers for accurate clinical diagnosis and computer-aided decision support systems. This paper presents a method to automatically segment liver and lesions in CT abdomen images using cascaded fully convolutional neural networks (CFCNs) and dense 3D conditional random fields (CRFs). We train and cascade two FCNs for a combined segmentation of the liver and its lesions. In the first step, we train a FCN to segment the liver as ROI input for a second FCN. The second FCN solely segments lesions from the predicted liver ROIs of step 1. We refine the segmentations of the CFCN using a dense 3D CRF that accounts for both spatial coherence and appearance. CFCN models were trained in a 2-fold cross-validation on the abdominal CT dataset 3DIRCAD comprising 15 hepatic tumor volumes. Our results show that CFCN-based semantic liver and lesion segmentation achieves Dice scores over 94% for liver with computation times below 100s per volume. We experimentally demonstrate the robustness of the proposed method as a decision support system with a high accuracy and speed for usage in daily clinical routine.

cs.CV↗

Time-dependent Mott transition in the periodic Anderson model with nonlocal hybridization

The time-dependent Mott transition in a periodic Anderson model with off-site, nearest-neighbor hybridization is studied within the framework of nonequilibrium self-energy functional theory. Using the two-site dynamical-impurity approximation, we compute the real-time dynamics of the optimal variational parameter and of different observables initiated by sudden quenches of the Hubbard-U and identify the critical interaction. The time-dependent transition is orbital selective, i.e., in the final state, reached in the long-time limit after the quench to the critical interaction, the Mott gap opens in the spectral function of the localized orbitals only. We discuss the dependence of the critical interaction and of the final-state effective temperature on the hybridization strength and point out the various similarities between the nonequilibrium and the equilibrium Mott transition. It is shown that these can also be smoothly connected to each other by increasing the duration of a U-ramp from a sudden quench to a quasi-static process. The physics found for the model with off-site hybridization is compared with the dynamical Mott transition in the single-orbital Hubbard model and with the dynamical crossover found for the real-time dynamics of the conventional Anderson lattice with on-site hybridization.

cond-mat.str-el↗