SearcharxivSearch

arXiv subjects

Feng-Lei Hong

Publications and source records attributed to Feng-Lei Hong.

At least 19 recordsLinked to original sources

Quantum Storage of Frequency-Multiplexed Photons Exhibiting Nonclassical Correlations with Telecom C-Band Photons

Multiplexing is essential for improving entanglement distribution rates in quantum communication. Frequency multiplexing provides a promising and scalable path toward large-capacity quantum networks. Further progress requires increasing the number of frequency modes and developing broadband photon-pair sources and quantum memories that are spectrally compatible. Here, we report the integration of a cavity-enhanced spontaneous parametric down-conversion source in the telecom C-band with a frequency-multiplexed atomic frequency comb memory. The bow-tie cavity source was simultaneously resonant at 606 nm and 1550 nm, generating non-degenerate photon pairs exhibiting a clustered frequency-comb spectrum. The atomic frequency comb memory, implemented in Praseodymium-doped Yttrium Orthosilicate crystals, provided up to 83 frequency modes with 123 MHz spacing and enabled broadband storage of 606 nm signal photons. By filtering the main cluster, we obtained $32.7 \pm 4.8$ effective modes, as confirmed from coincidence measurements. Importantly, we observed strong nonclassical correlations after storage, with cross-correlation values of $g_{s,i}^{(2)} = 8.1\pm0.7$. Our experimental results demonstrate the feasibility of integrating cavity-enhanced photon-pair sources with rare-earth-ion-doped solid-state memories. The integration reveals a high frequency multiplicity that is essential for scalable quantum networks.

quant-ph

Generation of a precise time scale assisted by a near-continuously operating optical lattice clock

We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb optical lattice clock operated with an uptime of 81.6 $\%$. During the 230-day period, the root mean square time variation of our time scale with respect to UTC is 0.52 ns, which is a better performance compared with those of time scales steered by microwave fountain clocks that exhibit root mean square variations from 0.99 ns to 1.6 ns. With the high uptime achieved by the Yb optical lattice clock, our simulation implies the potential of generating a state-of-the-art time scale with a time variation of $<0.1$ ns over a month using a better hydrogen maser reaching the mid $10^{-16}$ level. This work demonstrates that a use of an optical clock with a high uptime enhances the stability of a time scale.

physics.atom-ph

Frequency-multiplexed Hong-Ou-Mandel interference

The implementation of quantum repeaters needed for long-distance quantum communication requires the generation of quantum entanglement distributed among the elementary links. These entanglements must be swapped among the quantum repeaters through Bell-state measurements. This study aims to improve the entanglement generation rate by frequency multiplexing the Bell-state measurements. As a preliminary step of the frequency-multiplexed Bell-state measurements, three frequency modes are mapped to a temporal mode by an atomic frequency comb prepared in $\mathrm{Pr^{3+}}$ ion-doped $\mathrm{Y_2SiO_5}$ crystals using a weak coherent state, and Hong-Ou-Mandel interference, which is a measure of the indistinguishability of two inputs, is observed in each frequency mode by coincidence detection. The visibility for all the modes was 40%-42% (theoretically up to 50%). Furthermore, we show that a mixture of different modes is avoided. The present results are connected to frequency-selective Bell-state measurements and therefore frequency-multiplexed quantum repeaters.

quant-ph

Frequency-multiplexed storage and distribution of narrowband telecom photon pairs over a 10-km fiber link with long-term system stability

The ability to transmit quantum states over long distances is a fundamental requirement of the quantum internet and is reliant upon quantum repeaters. Quantum repeaters involve entangled photon sources that emit and deliver photonic entangled states at high rates and quantum memories that can temporarily store quantum states. Improvement of the entanglement distribution rate is essential for quantum repeaters, and multiplexing is expected to be a breakthrough. However, limited studies exist on multiplexed photon sources and their coupling with a multiplexed quantum memory. Here, we demonstrate the storing of a frequency-multiplexed two-photon source at telecommunication wavelengths in a quantum memory accepting visible wavelengths via wavelength conversion after 10-km distribution. To achieve this, quantum systems are connected via wavelength conversion with a frequency stabilization system and a noise reduction system. The developed system was stably operated for more than 42 h. Therefore, it can be applied to quantum repeater systems comprising various physical systems requiring long-term system stability.

quant-ph

Single-shot high-resolution identification of discrete frequency modes of single-photon-level optical pulses

Frequency-multiplexed quantum communication usually requires a single-shot identification of the frequency mode of a single photon . In this paper, we propose a scheme that can identify the frequency mode with high-resolution even for spontaneously emitted photons whose generation time is unknown, by combining the time-to-space and frequency-to-time mode mapping. We also demonstrate the mapping of the frequency mode (100 MHz intervals) to the temporal mode (435 ns intervals) for weak coherent pulses using atomic frequency combs. This frequency interval is close to the minimum frequency mode interval of the atomic frequency comb quantum memory with Pr3+ ion-doped Y2SiO5 crystal, and the proposed scheme has the potential to maximize the frequency multiplexing of the quantum repeater scheme with the memory.

quant-ph

Coupling of a quantum memory and telecommunication wavelength photons for high-rate entanglement distribution in quantum repeaters

Quantum repeaters are indispensable tools for long-distance quantum communication. However, frequency matching between entangled photon sources and remote quantum memories (QMs) is difficult, which is an obstacle to the implementation of quantum repeaters. In this paper, we demonstrate a method to achieve the coupling of a Pr:YSO as a fixed-time QM with a single telecommunication-wavelength photon through frequency stabilization using an optical frequency comb over all applied laser wavelengths. The demonstrated method can lead to the implementation of a quantum repeater scheme enabling an improvement of the entanglement generation rate, paving the way for long-distance quantum communication.

quant-ph

Offset-locking-based frequency stabilization of external cavity diode lasers for long-distance quantum communication

Quantum repeaters are required for long-distance quantum communication. For efficient coupling of quantum entangled photon sources with narrow-linewidth quantum memories we performed the frequency stabilization of two lasers at 1514 and 1010 nm. The 1514 nm pump laser of the entangled photon source exhibited a frequency stability of 3.6 \times 10^{-12} (τ= 1 s). The 1010 nm pump laser of the wavelength conversion system exhibited a frequency stability of 3.4 \times 10^{-12} (τ= 1 s). The stabilities of both lasers were approximately two orders of magnitude smaller than the frequency width of 4 MHz of the Pr:YSO quantum memory. Such frequency-stabilized lasers can realize the remote coupling of a quantum memory and an entangled photon source in quantum repeaters.

quant-ph

Demonstration of the nearly continuous operation of an $^{171}$Yb optical lattice clock for half a year

Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical lattice clocks has not yet reached a level comparable to that of Cs fountain clocks which contribute to International Atomic Time (TAI) by the nearly continuous operation. In this paper, we report the long-term operation of an $^{171}$Yb optical lattice clock with a coverage of 80.3% for half a year including uptimes of 93.9% for the first 24 days and 92.6% for the last 35 days. This enables a nearly dead-time-free frequency comparison of the optical lattice clock with TAI over months, which provides a link to the SI second with an uncertainty of low $10^{-16}$. By using this link, the absolute frequency of the $^{1}$S$_{0}-^{3}$P$_{0}$ clock transition of $^{171}$Yb is measured as 518 295 836 590 863.54(26) Hz with a fractional uncertainty of $5.0\times10^{-16}$. This value is in agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second.

physics.atom-ph

Improved Frequency Ratio Measurement with 87Sr and 171Yb Optical Lattice Clocks at NMIJ

We report improved frequency ratio measurement with $^{87}$Sr and $^{171}$Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The $^{87}$Sr optical lattice clock is enhanced with several major modifications and is re-evaluated with a reduced uncertainty of $1.1\times10^{-16}$. We employed a $^{171}$Yb optical lattice clock with an uncertainty of $4\times10^{-16}$ that was developed for contributing to International Atomic Time (TAI). The measurement result is $ν_{\mathrm{Yb}}/ν_{\mathrm{Sr}}$ = 1.207 507 039 343 338 58(49)$_{\mathrm{sys}}$(6)$_{\mathrm{stat}}$ with a fractional uncertainty of $4.1\times10^{-16}$, which is 3.4 times smaller than our previous measurement result.

physics.atom-ph

Current status of space gravitational wave antenna DECIGO and B-DECIGO

Deci-hertz Interferometer Gravitational Wave Observatory (DECIGO) is the future Japanese space mission with a frequency band of 0.1 Hz to 10 Hz. DECIGO aims at the detection of primordial gravitational waves, which could be produced during the inflationary period right after the birth of the universe. There are many other scientific objectives of DECIGO, including the direct measurement of the acceleration of the expansion of the universe, and reliable and accurate predictions of the timing and locations of neutron star/black hole binary coalescences. DECIGO consists of four clusters of observatories placed in the heliocentric orbit. Each cluster consists of three spacecraft, which form three Fabry-Perot Michelson interferometers with an arm length of 1,000 km. Three clusters of DECIGO will be placed far from each other, and the fourth cluster will be placed in the same position as one of the three clusters to obtain the correlation signals for the detection of the primordial gravitational waves. We plan to launch B-DECIGO, which is a scientific pathfinder of DECIGO, before DECIGO in the 2030s to demonstrate the technologies required for DECIGO, as well as to obtain fruitful scientific results to further expand the multi-messenger astronomy.

gr-qc

Uncertainty evaluation of an $^{171}$Yb optical lattice clock at NMIJ

We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the $\mathrm{6s^{2}\,^{1}S_{0}-6s6p\,^{3}P_{0}}$ clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift $d$ incorporated in a widely-used light shift model by RIKEN and the second-order Zeeman shift $a_{\mathrm{Z}}$ are improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient $d$ is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions $\mathrm{6s6p^{3}P_{0}-6s8p^{3}P_{0}}$, $\mathrm{6s8p^{3}P_{2}}$, and $\mathrm{6s5f^{3}F_{2}}$. The obtained values are $d=-1.1(4)$ $\mathrmμ$Hz and $a_{\mathrm{Z}}=-6.6(3)$ Hz/mT$^{2}$. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

physics.atom-ph

A compact frequency-stabilized pump laser for wavelength conversion in long-distance quantum communication

We demonstrate a compact frequency-stabilized laser at 1064 nm using Doppler-free saturation absorption spectroscopy of molecular iodine. The achieved laser frequency stability and linewidth are 5.7 10-12 (corresponding to an uncertainty of the laser frequency of 1.6 kHz) and 400 kHz, respectively. The developed frequency-stabilized laser can be used as a pump laser for wavelength conversion from visible to telecom (or vice versa) to connect quantum memories utilizing nitrogen-vacancy centers in diamond at remote nodes in fiber-based quantum communication.

quant-ph

Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms

We have developed an optical lattice clock that can operate in dual modes: a strontium (Sr) clock mode and an ytterbium (Yb) clock mode. Dual-mode operation of the Sr-Yb optical lattice clock is achieved by alternately cooling and trapping $^{87}$Sr and $^{171}$Yb atoms inside the vacuum chamber of the clock. Optical lattices for Sr and Yb atoms were arranged with horizontal and vertical configurations, respectively, resulting in a small distance of the order of 100 $μ$m between the trapped Sr and Yb atoms. The $^{1}$S$_{0}$-$^{3}$P$_{0}$ clock transitions in the trapped atoms were interrogated in turn and the clock lasers were stabilized to the transitions. We demonstrated the frequency ratio measurement of the Sr and Yb clock transitions by using the dual-mode operation of the Sr-Yb optical lattice clock. The dual-mode operation can reduce the uncertainty of the blackbody radiation shift in the frequency ratio measurement, because both Sr and Yb atoms share the same blackbody radiation.

physics.atom-ph

A frequency-stabilized light source at 399 nm using an Yb hollow-cathode lamp

We demonstrate a diode laser system operating at 399 nm that is stabilized to the ${\rm 6s^{2}\ {^1}S_{0} - 6s6p\ {^1}P_{1}}$ electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached $1.1 \times 10^{-11}$ at an averaging time of $τ= 1\ \mathrm{s}$. We performed an absolute frequency measurement using an optical frequency comb and determined that the absolute frequency of the laser stabilized to the ${\rm {^1}S_{0} - {^1}P_{1}}$ transition in $^{174}\mathrm{Yb}$ was 751 526 522.26(9) MHz. We also investigated several systematic frequency shifts while changing some of the light source parameters and measured several isotope shifts. The measured laser frequency will provide useful information regarding the practical use of the frequency-stabilized light source at 399 nm.

physics.atom-ph

Two-step frequency conversion for connecting distant quantum memories by transmission through an optical fiber

Long-distance quantum communication requires entanglement between distant quantum memories. For this purpose, photon transmission is necessary to connect the distant memories. Here, for the first time, we develop a two-step frequency conversion process (from a visible wavelength to a telecommunication wavelength and back) involving the use of independent two-frequency conversion media where the target quantum memories are nitrogen-vacancy centers in diamonds (with an emission/absorption wavelength of 637.2 nm), and experimentally characterize the performance of this process acting on light from an attenuated CW laser. A total conversion efficiency of approximately 7% is achieved. The noise generated in the frequency conversion processes is measured, and the signal-to-noise ratio is estimated for a single photon signal emitted by a nitrogen-vacancy (NV) center. The developed frequency conversion system has future applications via transmission through a long optical fiber channel at a telecommunication wavelength for a quantum repeater network.

quant-ph

Second harmonic generation at 399 nm resonant on the $^{1}S_{0}-^{1}P_{1}$ transition of ytterbium using a periodically poled LiNbO$_{3}$ waveguide

We demonstrate a compact and robust method for generating a 399-nm light resonant on the $^{1}S_{0}-^{1}P_{1}$ transition in ytterbium using a single-pass periodically poled LiNbO$_{3}$ waveguide for second harmonic generation (SHG). The obtained output power at 399 nm was 25 mW when a 798-nm fundamental power of 380 mW was coupled to the waveguide. We observed no degradation of the SHG power for 13 hours with a low power of 6 mW. The obtained SHG light has been used as a seed light for injection locking, which provides sufficient power for laser cooling ytterbium.

physics.atom-ph

Absolute frequency measurements and hyperfine structures of the molecular iodine transitions at 578 nm

We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical frequency comb. The relative uncertainties of the measured absolute frequencies are typically $1.4\times10^{-11}$. Accurate hyperfine constants of four rovibrational transitions are obtained by fitting the measured hyperfine splittings to a four-term effective Hamiltonian including the electric quadrupole, spin-rotation, tensor spin-spin, and scalar spin-spin interactions. The observed transitions can be good frequency references at 578 nm, and are especially useful for research using atomic ytterbium since the transitions are close to the $^{1}S_{0}-^{3}P_{0}$ clock transition of ytterbium.

physics.atom-ph

Improved frequency measurement of the $^1S_{0}$-$^3P_{0}$ clock transition in $^{87}$Sr using the Cs fountain clock at NMIJ as a transfer oscillator

We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.

physics.atom-ph