SearcharxivSearch

arXiv subjects

Fengbo Gu

Publications and source records attributed to Fengbo Gu.

4 recordsLinked to original sources

Characterization of FBK NUV-HD-Cryo SiPMs near LHe temperature

Five FBK ``NUV-HD-Cryo'' SiPMs have been characterized at 7 K and 10 K, with 405 nm and 530 nm LED light, respectively. The dark count rate (DCR) was measured to be $\sim$ 1 Hz for the $\sim$ 100 mm$^2$-size SiPMs, or 0.01 Hz/mm$^2$, which is $\sim$ 7 orders lower than the DCR at room temperature (RT). Given the very low DCR at these cryogenic temperatures, we measured the SiPMs' I-V curves with such a method: illuminated the SiPMs with weak light, which differs from the conventional measurements at RT. Then, we measured the photo-detection efficiency (PDE), after-pulse (AP), and cross-talk (CT) with a bias voltage ranging from overvoltage (OV) 5 to 11 V. At the OV interval (5 to 11 V), the PDE was between 20\% - 45\%, and the AP and CT were both between $\sim$ 5\% and $\sim$ 20\%. With an OV higher than 10 V, the PDE would be $\ge$ 40\%, and the AP and CT are $\sim$ 20\%. Combining all of the measurements, we are confident that the SiPMs can be equipped as the photosensors on liquid helium detectors, including but not limited to the time projection chambers, which we have proposed in hunting for low-mass dark matter directly and beyond.

physics.ins-det

Conceptual design and progress of transmitting $\sim$ MV DC HV into 4 K LHe detectors

A dual-phase TPC (Time Projection Chamber) is more advanced in characterizing an event than a single-phase one because it can, in principle, reconstruct the 3D (X-Y-Z) image of the event, while a single-phase detector can only show a 2D (X-Y) picture. As a result, more enriched physics is expected for a dual-phase detector than a single-phase one. However, to build such a detector, DC HV (High Voltage) must be delivered into the chamber (to have a static electric field), which is a challenging task, especially for an LHe detector due to the extremely low temperature, $\sim$ 4 K, and the very high voltage, $\sim$ MV (Million Volts). This article introduces a convincing design for transmitting $\sim$ MV DC into a 4 K LHe detector. We also report the progress of manufacturing a 100 kV DC feedthrough capable of working at 4 K. Surprisingly, we realized that the technology we developed here might be a valuable reference to the scientists and engineers aiming to build residential bases on the Moon or Mars.

physics.ins-det

A novel nuclear recoil calibration for liquid noble gas detectors

According to many dark matter models, a potential signal registered in a detector would feature a single-scattering nuclear recoil (NR). So, it is crucial to calibrate the detector's response to NR events. The conventional calibrations implement $\sim$ keV to MeV neutrons, which can be produced by an accelerator, a neutron generator, or a radioactive source. Although the calibrating methods have been widely employed, they could be improved in several ways: (a) the incident neutron energy should be more monoenergetic, (b) the calibrating NR energy should line up with the region of interest (ROI) of the experiment, and (c) the intensity of the beam should be appropriate. In the paper, we introduce a novel NR calibration method for liquid helium detectors, in which a helium beam ($\alpha$ particles) will be implemented to calibrate the detectors. The helium beam can (i) be tuned precisely to have a jitter of $\lesssim $ 4\% (the $\alpha$ beam's kinetic energy is equivalent to the recoil energy in the conventional calibrations with fast neutrons); (ii) have an energy between $\sim$ 100 eV and tens of keV; and (iii) provide a tunable flux from nA to 100 $\mu$A, which presents convenience in beam pipe configuration to obtain a $\sim$ 100 Hz events rate so that the events pileup would be ignorable.

physics.ins-det

Search for ER and/or NR-like dark matter signals with the especially low background liquid helium TPCs

In the Dark Matter (DM) direct detection community, the absence of convincing signals has become a "new normal" for decades. Among other possibilities, the "new normal" might indicate that DM-matter interactions could generate not only the hypothetical NR (Nuclear Recoil) events but also the ER (Electron Recoil) ones, which have often been tagged as backgrounds historically. Further, we argue that ER and NR-like DM signals could co-exist in a DM detector's same dataset. So in total, there would be three scenarios we can search for DM signals: (i) ER excess only, (ii) NR excess only, and (iii) ER and NR excesses combined. To effectively identify any possible DM signal under the three scenarios, a DM detector should (a) have the minimum ER and NR backgrounds and (b) be capable of discriminating ER events from NR ones. Accordingly, we introduce the newly established project, ALETHEIA, which implements liquid helium-filled TPCs (Time Projection Chambers) in hunting for DM. Thanks to the nearly single-digit number of ER and NR backgrounds on 1 ton*yr exposure, presumably, the ALETHEIA detectors could identify any form of DM-induced excess in its ROI (Research Of Interest). As far as we know, ALETHEIA is the first DM direct detection experiment claiming such an inclusive search; conventional detectors search DM mainly on the "ER excess only" and/or the "NR excess only" channel, not the "ER and NR excesses combined" channel.

astro-ph.IM