Searcharxiv⌕ Search

arXiv subjects

Ferdinando Rodriguez y Baena

Publications and source records attributed to Ferdinando Rodriguez y Baena.

21 records · Page 2Linked to original sources

Accelerating Surgical Robotics Research: A Review of 10 Years With the da Vinci Research Kit

Robotic-assisted surgery is now well-established in clinical practice and has become the gold standard clinical treatment option for several clinical indications. The field of robotic-assisted surgery is expected to grow substantially in the next decade with a range of new robotic devices emerging to address unmet clinical needs across different specialities. A vibrant surgical robotics research community is pivotal for conceptualizing such new systems as well as for developing and training the engineers and scientists to translate them into practice. The da Vinci Research Kit (dVRK), an academic and industry collaborative effort to re-purpose decommissioned da Vinci surgical systems (Intuitive Surgical Inc, CA, USA) as a research platform for surgical robotics research, has been a key initiative for addressing a barrier to entry for new research groups in surgical robotics. In this paper, we present an extensive review of the publications that have been facilitated by the dVRK over the past decade. We classify research efforts into different categories and outline some of the major challenges and needs for the robotics community to maintain this initiative and build upon it.

cs.RO↗

Rotation-constrained optical see-through headset calibration withbare-hand alignment

The inaccessibility of user-perceived reality remains an open issue in pursuing the accurate calibration of optical see-through (OST) head-mounted displays (HMDs). Manual user alignment is usually required to collect a set of virtual-to-real correspondences, so that a default or an offline display calibration can be updated to account for the user's eye position(s). Current alignment-based calibration procedures usually require point-wise alignments between rendered image point(s) and associated physical landmark(s) of a target calibration tool. As each alignment can only provide one or a few correspondences, repeated alignments are required to ensure calibration quality. This work presents an accurate and tool-less online OST calibration method to update an offline-calibrated eye-display model. The user's bare hand is markerlessly tracked by a commercial RGBD camera anchored to the OST headset to generate a user-specific cursor for correspondence collection. The required alignment is object-wise, and can provide thousands of unordered corresponding points in tracked space. The collected correspondences are registered by a proposed rotation-constrained iterative closest point (rcICP) method to optimise the viewpoint-related calibration parameters. We implemented such a method for the Microsoft HoloLens 1. The resiliency of the proposed procedure to noisy data was evaluated through simulated tests and real experiments performed with an eye-replacement camera. According to the simulation test, the rcICP registration is robust against possible user-induced rotational misalignment. With a single alignment, our method achieves 8.81 arcmin (1.37 mm) positional error and 1.76 degree rotational error by camera-based tests in the arm-reach distance, and 10.79 arcmin (7.71 pixels) reprojection error by user tests.

cs.GT↗

Occlusion-robust Visual Markerless Bone Tracking for Computer-Assisted Orthopaedic Surgery

Conventional computer-assisted orthopaedic navigation systems rely on the tracking of dedicated optical markers for patient poses, which makes the surgical workflow more invasive, tedious, and expensive. Visual tracking has recently been proposed to measure the target anatomy in a markerless and effortless way, but the existing methods fail under real-world occlusion caused by intraoperative interventions. Furthermore, such methods are hardware-specific and not accurate enough for surgical applications. In this paper, we propose a RGB-D sensing-based markerless tracking method that is robust against occlusion. We design a new segmentation network that features dynamic region-of-interest prediction and robust 3D point cloud segmentation. As it is expensive to collect large-scale training data with occlusion instances, we also propose a new method to create synthetic RGB-D images for network training. Experimental results show that our proposed markerless tracking method outperforms recent state-of-the-art approaches by a large margin, especially when an occlusion exists. Furthermore, our method generalises well to new cameras and new target models, including a cadaver, without the need for network retraining. In practice, by using a high-quality commercial RGB-D camera, our proposed visual tracking method achieves an accuracy of 1-2 degress and 2-4 mm on a model knee, which meets the standard for clinical applications.

cs.CV↗