SearcharxivSearch

arXiv subjects

Flavien Bureau

Publications and source records attributed to Flavien Bureau.

9 recordsLinked to original sources

An angular distortion matrix approach for joint wave-speed tomography and aberration correction in scattering media

Despite being one of the most fundamental properties governing wave propagation, the wave-speed distribution is rarely known accurately in reflection imaging. Its estimation relies on analyzing wave distortions undergone by the incident and reflected waves; however, their contribution is difficult to disentangle from the medium reflectivity, particularly in complex media dominated by speckle. Mismatches between assumed and actual wave speeds result in aberrations that degrade the quality of reflectivity images. Yet these aberrations carry information about the underlying wave-speed heterogeneities. Here, we show that an angular distortion matrix, built upon matrix imaging, can unscramble this information to map the wave speed and correct aberrations across the entire field of view. At each point, this matrix isolates the distortions accumulated by the incident and reflected waves along well-defined propagation directions. It reveals strong angular correlations that can be exploited through time-reversal analysis to estimate local phase aberrations, providing observables for wave-speed tomography. The resulting map improves the propagation model used for matrix imaging, after which the process is iterated to refine the wave speed until residual aberrations become negligible. Using ultrasound as proof of concept, we validate the approach in a tissue-mimicking phantom and illustrate its clinical potential in vivo for breast and liver imaging. Sound-speed maps show contrast consistent with a malignant breast lesion and expected values in a healthy liver, while aberration correction sharpens reflectivity images routinely interpreted by clinicians. Beyond ultrasound, the approach extends naturally to any wave modality in which reflection-matrix imaging can be implemented.

physics.app-ph

Self-Portrait of the Focusing Process in Speckle: I. Spatio-Temporal Imaging of Wave Packets in Complex Media

This is the first article in a series of three dealing with the exploitation of speckle for imaging purposes. Speckle is the complex interference wave-field produced by a random distribution of un-resolved scatterers. In this paper, we show how these scatterers can be used as virtual microphones to monitor the spatio-temporal propagation of a wave-packet inside the medium. To do so, the concept of matrix imaging is particularly useful. It consists in decoupling the location of the transmitted and received focal spots in a standard beamforming process. By scanning the wave-field with the output focal spot that then acts as a virtual transducer, one can image the spatio-temporal evolution of the wave-packet inside the medium. This unique observable will allow us to highlight the imperfections of the focusing process, in particular the defocus and reverberations induced by a strong aberrating layer. As a proof-of-concept, we will consider ultrasound experiments on tissue-mimicking phantoms. In the next two papers, we will show how this observable can be leveraged to compensate for these phenomena that hamper wave focusing and imaging in all fields of wave physics. Our method is indeed broadly applicable to different types of waves beyond ultrasound for which multi-element technology allows a reflection matrix to be measured.

physics.app-ph

Self-Portrait of the Focusing Process in Speckle: III. Tailoring Complex Spatio-Temporal Focusing Laws To Overcome Reverberations in Reflection Imaging

This is the third article in a series of three dealing with the exploitation of speckle for imaging purposes. In complex media, a fundamental limit is the multiple scattering phenomenon that completely blurs the imaging process in depth. Matrix imaging can provide a relevant framework for solving this problem. As it proved to be an adequate tool for probing reverberations in speckle [E. Giraudat et al., Part I], we will show how it can be used to tailor complex spatio-temporal focusing laws to monitor the interference between the multiply-reflected paths and the ballistic component of the wave-field. To do so, we extend the distortion matrix concept to the frequency domain. An iterative phase reversal process operated from the space-time Fourier space is then used to compensate for reverberations and optimize both the axial and transverse resolution of the confocal image. Here, we first present an experimental proof-of-concept consisting in imaging a tissue-mimicking phantom through a reverberating plate before outlining the potential and the limits of this strategy for transcranial ultrasound and beyond.

physics.app-ph

Ultrasound matrix imaging for 3D transcranial in vivo localization microscopy

Transcranial ultrasound imaging is usually limited by skull-induced attenuation and high-order aberrations. By using contrast agents such as microbubbles in combination with ultrafast imaging, not only can the signal-to-noise ratio be improved, but super-resolution images down to the micrometer scale of the brain vessels can also be obtained. However, ultrasound localization microscopy (ULM) remains affected by wavefront distortions that limit the microbubble detection rate and hamper their localization. In this work, we show how ultrasound matrix imaging, which relies on the prior recording of the reflection matrix, can provide a solution to these fundamental issues. As an experimental proof of concept, an in vivo reconstruction of deep brain microvessels is performed on three anesthetized sheep. The compensation of wave distortions is shown to markedly enhance the contrast and resolution of ULM. This experimental study thus opens up promising perspectives for a transcranial and nonionizing observation of human cerebral microvascular pathologies, such as stroke.

physics.med-ph

Label-free subcellular 3D imaging of oocytes and embryos via reflection matrix microscopy

Non-invasive morphological assessment is the cornerstone of oocyte and embryo selection in assisted reproductive technology, yet clinical practice remains limited by two-dimensional, qualitative microscopy. While three-dimensional (3D) fluorescence imaging provides cellular insights, its inherent phototoxicity precludes routine clinical use. Conversely, existing label-free modalities fail to resolve subcellular structures in thick specimens due to two distinct physical barriers: large-scale refractive index heterogeneities, such as the cumulus cells surrounding oocytes, that induce severe aberrations; and short-scale fluctuations, primarily from cytoplasmic lipids, that generate a multiple scattering ``fog''. Here, we report an ultra-fast Reflection Matrix Imaging (RMI) platform designed to overcome these depth and resolution limits. By capturing the back-scattered electromagnetic field for a set of plane-wave illuminations at multiple wavelengths, we record a multi-spectral reflection matrix. From this matrix, we leverage digital adaptive focusing algorithms to computationally compensate for sample-induced aberrations while realigning forward multiple scattering trajectories with the single-scattering contribution. This approach enables label-free 3D visualization of oocytes and blastocysts with an unprecedented subcellular resolution of 300 nm throughout the entire specimen volume. We demonstrate the reliable identification of germinal vesicles and nuclear status in stages previously inaccessible to conventional optics, including imaging through dense cumulus cells. Our method provides a powerful, non-invasive tool for objective grading across all pre-implantation stages, potentially transforming decision-making in clinical IVF.

physics.optics

Self-Portrait of the Focusing Process in Speckle: II. Gouy Phase Shift for Defocus Correction and Pixel Depth Reassignment

This is the second article in a series of three dealing with the exploitation of speckle for aberration correction and reverberation compensation in reflection imaging. When probing heterogeneous media with waves, we have to cope with multi-scale fluctuations of the wave velocity. On the one hand, short-scale heterogeneities induce back-scattered echoes whose random interference generate a speckle pattern on the beamformed image. On the other hand, large-scale fluctuations of the wave-velocity can distort the focused wave-fronts, resulting in aberrations on the same image. In this paper, we show how the self-portrait of the wave evolves as a function of the speed-of-sound model. Strikingly, a Gouy phase shift is observed when the speed-of-sound model is optimal. This particularly sensitive feature enables: (i) an optimization of the speed-of-sound model for each pixel of the image; (ii) a local and fine compensation of defocus across the field-of-view, thereby compensating for most aberrations in the image. Experiment in a tissue-mimicking phantom and numerical simulations are first presented to validate our method. It is then applied to in-vivo liver data of a difficult-to-image patient. The speed-of-sound optimization allows an axial compensation of aberrations and a depth-reassignment of each singly-scattered echo to the actual position of the associated scatterer. As distance measurement is often critical for diagnosis, such a wave speed optimization can be crucial for ultrasound but also for any other imaging methods based on the principle of echo-location.

physics.med-ph

Reflection Measurement of the Scattering Mean Free Path at the Onset of Multiple Scattering

Multiple scattering of waves presents challenges for imaging complex media but offers potential for their characterization. Its onset is actually governed by the scattering mean free path $\ell_s$ that provides crucial information on the medium micro-architecture. Here, we introduce a reflection matrix method designed to estimate this parameter from the time decay of the single scattering rate. Our method is first validated by an ultrasound experiment on a tissue-mimicking phantom before being applied in-vivo to a human liver. This study opens important perspectives for quantitative imaging of heterogeneous media with waves, whether it be for non-destructive testing, biomedical or geophysical applications.

physics.med-ph

Three-Dimensional Ultrasound Matrix Imaging

Matrix imaging paves the way towards a next revolution in wave physics. Based on the response matrix recorded between a set of sensors, it enables an optimized compensation of aberration phenomena and multiple scattering events that usually drastically hinder the focusing process in heterogeneous media. Although it gave rise to spectacular results in optical microscopy or seismic imaging, the success of matrix imaging has been so far relatively limited with ultrasonic waves because wave control is generally only performed with a linear array of transducers. In this paper, we extend ultrasound matrix imaging to a 3D geometry. Switching from a 1D to a 2D probe enables a much sharper estimation of the transmission matrix that links each transducer and each medium voxel. Here, we first present an experimental proof of concept on a tissue-mimicking phantom through ex-vivo tissues and then, show the potential of 3D matrix imaging for transcranial applications.

eess.IV

Freeze-dried microfluidic monodisperse microbubbles as a new generation of ultrasound contrast agents

In the paper, we succeeded to freeze-dry monodisperse microbubbles without degrading their size and acoustic properties. We used microfluidic technology to generate highly monodisperse (coefficient of variation, CV<5%) microbubbles and optimized their formulation along with a cryoprotectant. By using a specific technique of retrieval of the bubble, we showed that freeze-drying the microbubbles does not alter their size distribution. To compare the fundamental resonance properties of the bubbles, we performed backscattered acoustic characterization measurements. Our experimental results revealed that the freeze-drying process conserved the acoustic properties of the bubbles. The maximum backscattering power amplitude of fresh and freeze-dried monodisperse PVA bubbles was around ten eight times higher than that of SonoVue at a similar concentration in vitro. By solving the question of storage and transportation of monodisperse bubbles, our work facilitates their penetration in the domain of UCAs, for performing new tasks and developing novel non-invasive measurements, such as pressure, unaccessible to the existing commercialized bubbles.

physics.med-ph