SearcharxivSearch

arXiv subjects

Florence Levy-Bertrand

Publications and source records attributed to Florence Levy-Bertrand.

9 recordsLinked to original sources

CONCERTO: Instrument model of Fourier transform spectroscopy, white-noise components

Modern astrophysics relies on intricate instrument setups to meet the demands of sensitivity, sky coverage, and multi-channel observations. An example is the CONCERTO project, employing advanced technology like kinetic inductance detectors and a Martin-Puplett interferometer. This instrument, installed at the APEX telescope atop the Chajnantor plateau, began commissioning observations in April 2021. Following a successful commissioning phase that concluded in June 2021, CONCERTO was offered to the scientific community for observations, with a final observing run in December 2022. CONCERTO boasts an 18.5 arcmin field of view and a spectral resolution down to 1.45 GHz in the 130-310 GHz electromagnetic band. We developed a comprehensive instrument model of CONCERTO inspired by Fourier transform spectrometry principles to optimize performance and address systematic errors. This model integrates instrument noises, subsystem characteristics, and celestial signals, leveraging both physical data and simulations. Our methodology involves delineating simulation components, executing on-sky simulations, and comparing results with real observations. The resulting instrument model is pivotal, enabling a precise error correction and enhancing the reliability of astrophysical insights obtained from observational data. In this work, we focus on the description of three white-noise noise components included in the instrument model that characterize the white-noise level: the photon, the generation-recombination, and the amplifier noises.

astro-ph.IM

CONCERTO: instrument and status

CONCERTO (CarbON CII line in post-rEionization and ReionizaTiOn) is a low-resolution Fourier transform spectrometer dedicated to the study of star-forming galaxies and clusters of galaxies in the transparent millimeter windows from the ground. It is characterized by a wide instantaneous 18.6 arcmin field of view, operates at 130-310 GHz, and was installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. CONCERTO's double focal planes host two arrays of 2152 kinetic inductance detectors and represent a pioneering instrument to meet a state-of-the-art scientific challenge. This paper introduces the CONCERTO instrument and explains its status, shows the first CONCERTO spectral maps of Orion, and describes the perspectives of the project.

astro-ph.IM

Superconductor-ferromagnet hybrids for non-reciprocal electronics and detectors

We review the use of hybrid thin films composed of superconductors and ferromagnets for creating non-reciprocal electronic components and self-biased detectors of electromagnetic radiation. We begin by introducing the theory behind these effects, as well as discussing various potential materials that can be used in the fabrication of these components. We then proceed with a detailed discussion on the fabrication and characterization of Al/EuS/Cu and EuS/Al/Co-based detectors, along with their noise analysis. Additionally, we suggest some approaches for multiplexing such self-biased detectors.

cond-mat.supr-con

A millimetre-wave superconducting hyper-spectral device

Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for example from the primordial galaxies, as a function of redshift. Hyper-spectral integrated devices have the potential to replace the current Fourier transform, or the planned Fabry-Perot-based instruments operating at millimetre and sub-millimetre wavelengths. The aim is to perform hyper-spectral mapping, with a spectral resolution R= 100-1000, over large, i.e. thousands of beams, instantaneous patches of the Sky. The innovative integrated device that we have developed allows avoiding moving parts, complicated and/or dispersive optics or tunable filters to be operated at cryogenic temperatures. The prototype hyper-spectral focal plane is sensitive in the 75-90GHz range and contains nineteen horns for sixteen spectral-imaging channels, each selecting a frequency band of about 0.1GHz. For each channel a conical horn antenna, coupled to a planar superconducting resonant absorber made of thin aluminium, collects the radiation. A capacitively coupled titanium-aluminium bilayer Lumped Element Kinetic Inductance Detector (LEKID) is then in charge of dissipating and sensing the super-current established in the resonant absorber. The prototype is fabricated with only two photo-lithography steps over a commercial mono-crystalline sapphire substrate. It exhibits a spectral resolution of about 800. The optical noise equivalent power of the best channels is in the observational relevant 4E-17W/sqrt(Hz) range. The average sensitivity of all the channels is around 1E-16W/sqrt(Hz). The device, as expected from 3-D simulations, is polarisation-sensitive, paving the way to spectro-polarimetry measurements over very large instantaneous field-of-views.

astro-ph.IM

A horn-coupled millimeter-wave on-chip spectrometer based on Lumped Element Kinetic Inductance Detectors

Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large telescopes. Aims. New smart focal planes are needed to bridge the gap between large bandwidth continuum instruments operating on single dish telescopes and the high spectral and angular resolution interferometers (e.g. ALMA in Chile, NOEMA in France). The aim is to perform low-medium spectral resolution observations and select a lower number of potentially interesting sources, i.e. high-redshift galaxies, for further follow-up. Methods. We have designed, fabricated and tested an innovative on-chip spectrometer sensitive in the 85-110~GHz range. It contains sixteen channels selecting a frequency band of about 0.2 GHz each. A conical horn antenna coupled to a slot in the ground plane collects the radiation and guides it to a mm-wave microstrip transmission line placed on the other side of the mono-crystalline substrate. The mm-wave line is coupled to a filter-bank. Each filter is capacitively coupled to a Lumped Element Kinetic Inductance Detector (LEKID). The microstrip configuration allows to benefit from the high quality, i.e. low losses, mono-crystalline substrate, and at the same time prevents direct, i.e. un-filtered, LEKID illumination. Results. The prototype spectrometer exhibit a spectral resolution R = lambda / Delta_lambda = 300. The optical noise equivalent power is in the low 1E-16W/sqrt(Hz) range for an incoming power of about 0.2pW per channel. The device is polarisation-sensitive, with a cross-polarisation lower than 1% for the best channels.

astro-ph.IM

CONCERTO: a breakthrough in wide field-of-view spectroscopy at millimeter wavelengths

CarbON CII line in post-rEionization and ReionizaTiOn (CONCERTO) is a low-resolution spectrometer with an instantaneous field-of-view of 18.6 arcmin, operating in the 130-310 GHz transparent atmospheric window. It is installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. The Fourier transform spectrometer (FTS) contains two focal planes hosting a total of 4304 kinetic inductance detectors. The FTS interferometric pattern is recorded on the fly while continuously scanning the sky. One of the goals of CONCERTO is to characterize the large-scale structure of the Universe by observing the integrated emission from unresolved galaxies. This methodology is an innovative technique and is called line intensity mapping. In this paper, we describe the CONCERTO instrument, the effect of the vibration of the FTS beamsplitter, and the status of the CONCERTO main survey.

astro-ph.IM

Contact-less phonon detection with massive cryogenic absorbers

We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized on a 30-grams high-resistivity silicon crystal. The lumped-element resonator is inductively excited/read-out by a radio-frequency microstrip feed-line deposited on another wafer; the sensor, a Kinetic Inductance Detector (KID), is read-out without any physical contact or wiring to the absorber. The resonator demonstrates excellent electrical properties, particularly in terms of its internal quality factor. The detection of alphas and gammas in the massive absorber is achieved, with an RMS energy resolution of about 1.4 keV, which is already interesting for particle physics applications. The resolution of this prototype detector is mainly limited by the low (about 0.3%) conversion efficiency of deposited energy to superconducting excitations (quasi-particles). The demonstrated technique can be further optimized, and used to produce large arrays of a-thermal phonon detectors, for use in rare events searches such as: dark matter direct detection,neutrino-less double beta decay, or coherent elastic neutrino-nucleus scattering.

physics.ins-det

Quasiparticle dynamics in granular aluminum close to the superconductor to insulator transition

Superconducting high kinetic inductance elements constitute a valuable resource for quantum circuit design and millimeter-wave detection. Granular aluminum (GrAl) in the superconducting regime is a particularly interesting material since it has already shown a kinetic inductance in the range of nH$/\Box$ and its deposition is compatible with conventional Al/AlOx/Al Josephson junction fabrication. We characterize microwave resonators fabricated from GrAl with a room temperature resistivity of $4 \times 10^3\,μΩ\cdot$cm, which is a factor of 3 below the superconductor to insulator transition, showing a kinetic inductance fraction close to unity. The measured internal quality factors are on the order of $Q_{\mathrm{i}} = 10^5$ in the single photon regime, and we demonstrate that non-equilibrium quasiparticles (QP) constitute the dominant loss mechanism. We extract QP relaxation times in the range of 1 s and we observe QP bursts every $\sim 20$ s. The current level of coherence of GrAl resonators makes them attractive for integration in quantum devices, while it also evidences the need to reduce the density of non-equilibrium QPs.

cond-mat.supr-con

THz Magneto-electric atomic rotations in the chiral compound Ba$_3$NbFe$_3$Si$_2$O$_{14}$

We have determined the terahertz spectrum of the chiral langasite Ba$_3$NbFe$_3$Si$_2$O$_{14}$ by means of synchrotron-radiation measurements. Two excitations are revealed that are shown to have a different nature. The first one, purely magnetic, is observed at low temperature in the magnetically ordered phase and is assigned to a magnon. The second one persits far into the paramagnetic phase and exhibits both an electric and a magnetic activity at slightly different energies. This magnetoelectric excitation is interpreted in terms of atomic rotations and requires a helical electric polarization.

cond-mat.str-el