SearcharxivSearch

arXiv subjects

Florian Braun

Publications and source records attributed to Florian Braun.

4 recordsLinked to original sources

Interpretable Cross-Lingual Alignment in Small Language Models: Probing Cultural and Pragmatic Reasoning in Japanese-English Bilingual LLMs

Large language models work well on English and behave in poorly understood ways on languages typologically far from it. Japanese is a clean example, where evaluation still leans on translation quality and JGLUE-style benchmarks, which roll lexical, syntactic and pragmatic competence into a single score. The phenomena on which general-purpose models fail Japanese users are pragmatic: honorifics, in-group and out-group reference, context-sensitive politeness, zero anaphora. I introduce J-PragEval-v0, a minimal-pair benchmark isolating four such phenomena from surface fluency, and combine it with linear probes and teacher-forced log-probability evaluation to ask where inside TinySwallow-1.5B (28 layers, hidden size 1536) the corresponding contrasts live. The four features split three ways. Honorific register sits cleanly in the residual stream: 0.96 balanced accuracy at layer 15, and the model flips its preferred continuation with the scenario on 93 percent of items. Implicit subject and in-group reference are not linearly decodable at the final prompt token (0.48 and 0.38), yet flip rates are 0.77 and 0.79, so the contrast is worked out during generation rather than stored at the prompt. Indirect refusal is the negative case: 0.95 probe accuracy collapsing to a 0.43 flip rate under length-normalised teacher forcing, because the current minimal pairs conflate politeness with continuation length. I also specify Pragmatic Representation Steering, a parameter-free inference-time method that edits residual-stream activations along the class-mean-difference directions probing identifies. Feasibility is argued indirectly rather than demonstrated: the contrastive activation addition baseline, the same geometry the method would inject, recovers probe accuracy within one to two points of logistic regression wherever a linear signal exists. Scaling to Llama-3.1-Swallow-8B is the next step.

cs.CL

Excess Separability: Nuisance-Controlled Residual-Stream Probing for Benchmark Contamination Detection

Benchmark contamination is diagnosed with n-gram overlap, likelihood-based membership inference, or canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at release. A recent alternative reads it off a linear probe on internal activations. We show the natural way to do this does not work, specify one that survives measurement, then find that the correction making it work carries more variance than the null it is tested against. The protocol reports a zero-sum contrast on the depth profile of probe accuracy, recentred on a level-matched placebo baseline, tested against a label-permutation null, with the reference set twice the size of the suspect set. Each choice replaces a simpler alternative we rejected on measurement. Reporting the level of excess separability rather than its shape makes the false positive rate track the size of the analyst's own control set, 0.03 to 0.99 under a true null. Contrasting against a flat depth profile rejects a true null 0.72 of the time when surface decodability rises with depth, and loses all power when it falls. On real transformers the protocol fails a test the simulations did not pose. The recentring subtracts an estimate, and the permutation null holds it fixed. Re-estimated across split seeds on four audits of contaminated checkpoints, its standard deviation is 1.30 to 1.56 times the null's own in every arm: what is subtracted to remove a bias is more variable than what it corrects. The one nominally significant result, p = 0.0075, becomes 0.0745 once that variance is propagated, and no verdict is issued. The simulations missed this because their surface key is the covariate driving item variation; on real text it is a proxy, and degrading key quality in simulation reproduces it. We add a companion measurement and a widened null. No arm shows contamination.

cs.CL

Deep mouse brain two-photon near-infrared fluorescence imaging using a superconducting nanowire single-photon detector array

Two-photon microscopy (2PM) has become an important tool in biology to study the structure and function of intact tissues in-vivo. However, adult mammalian tissues such as the mouse brain are highly scattering, thereby putting fundamental limits on the achievable imaging depth, which typically resides around 600-800um. In principle, shifting both the excitation as well as (fluorescence) emission light to the shortwave near-infrared (SWIR, 1000-1700 nm) region promises substantially deeper imaging in 2PM, yet has proven challenging in the past due to the limited availability of detectors and probes in this wavelength region. To overcome these limitations and fully capitalize on the SWIR region, in this work we introduce a novel array of superconducting nanowire single-photon detectors (SNSPDs) and associated custom detection electronics for the use in near-infrared 2PM. The SNSPD array exhibits high efficiency and dynamic range, as well as low dark-count rates over a wide wavelength range. Additionally, the electronics and software permit seamless integration into typical 2PM systems. Together with a fluorescent dye emitting at 1105 nm, we report imaging depth of > 1.1mm in the in-vivo mouse brain, limited only by available labeling density and laser power. Our work further establishes SWIR 2PM approaches and SNSPDs as promising technologies for deep tissue biological imaging.

physics.optics

Versatile Airborne Ultrasonic NDT Technologies via Active Omni-Sliding with Over-Actuated Aerial Vehicles

This paper presents the utilization of advanced methodologies in aerial manipulation to address meaningful industrial applications and develop versatile ultrasonic Non-Destructive Testing (NDT) technologies with aerial robots. The primary objectives of this work are to enable multi-point measurements through sliding without re-approaching the work surface, and facilitate the representation of material thickness with B and C scans via dynamic scanning in arbitrary directions (i.e. omnidirections). To accomplish these objectives, a payload that can slide in omnidirections (here we call the omni-sliding payload) is designed for an over-actuated aerial vehicle, ensuring truly omnidirectional sliding mobility while exerting consistent forces in contact with a flat work surface. The omni-sliding payload is equipped with an omniwheel-based active end-effector and an Electro Magnetic Acoustic Transducer (EMAT). Furthermore, to ensure successful development of the designed payload and integration with the aerial vehicle, a comprehensive studying on contact conditions and system dynamics during active sliding is presented, and the derived system constraints are later used as guidelines for the hardware development and control setting. The proposed methods are validated through experiments, encompassing both the wall-sliding task and dynamic scanning for Ultrasonic Testing (UT), employing the aerial platform - Voliro T.

cs.RO