Deformable Image Registration of Dark-Field Chest Radiographs for Local Lung Signal Change Assessment

Dark-field radiography of the human chest has been demonstrated to have promising potential for the analysis of the lung microstructure and the diagnosis of respiratory diseases. However, previous studies of dark-field chest radiographs evaluated the lung signal only in the inspiratory breathing state. Our work aims to add a new perspective to these previous assessments by locally comparing dark-field lung information between different respiratory states. To this end, we discuss suitable image registration methods for dark-field chest radiographs to enable consistent spatial alignment of the lung in distinct breathing states. Utilizing full inspiration and expiration scans from a clinical chronic obstructive pulmonary disease study, we assess the performance of the proposed registration framework and outline applicable evaluation approaches. Our regional characterization of lung dark-field signal changes between the breathing states provides a proof-of-principle that dynamic radiography-based lung function assessment approaches may benefit from considering registered dark-field images in addition to standard plain chest radiographs.

eess.IV

Influence of Medical Foreign Bodies on Dark-Field Chest Radiographs: First experiences

Objectives: Evaluating the effects and artifacts introduced by medical foreign bodies in clinical dark-field chest radiographs and assessing their influence on the evaluation of pulmonary tissue, compared to conventional radiographs. Material & Methods: This retrospective study analyzed data from subjects enrolled in clinical trials conducted between 2018 and 2021, focusing on chronic obstructive pulmonary disease (COPD) and COVID-19 patients. All patients obtained a radiograph using an in-house developed clinical prototype for grating-based dark-field chest radiography. The prototype simultaneously delivers a conventional and dark-field radiograph. Two radiologists independently assessed the clinical studies to identify patients with foreign bodies. Subsequently, an analysis was conducted on the effects and artifacts attributed to distinct foreign bodies and their impact on the assessment of pulmonary tissue. Results: Overall, 30 subjects with foreign bodies were included in this study (mean age, 64 years +/- 11 [standard deviation]; 15 men). Foreign bodies composed of materials lacking microstructure exhibited a diminished dark-field signal or no discernible signal. Foreign bodies with a microstructure, in our investigations the cementation of the kyphoplasty, produce a positive dark-field signal. Since most foreign bodies lack microstructural features, dark-field imaging revealed fewer signals and artifacts by foreign bodies compared to conventional radiographs. Conclusion: Dark-field radiography enhances the assessment of pulmonary tissue with overlaying foreign bodies compared to conventional radiography. Reduced interfering signals result in fewer overlapping radiopaque artifacts within the investigated regions. This mitigates the impact on image quality and interpretability of the radiographs and the projection-related limitations of radiography compared to CT.

physics.med-ph

Estimating Total Lung Volume from Pixel-level Thickness Maps of Chest Radiographs Using Deep Learning

Purpose: To estimate the total lung volume (TLV) from real and synthetic frontal chest radiographs (CXR) on a pixel level using lung thickness maps generated by a U-Net deep learning model. Methods: This retrospective study included 5,959 chest CT scans from two public datasets: the lung nodule analysis 2016 (n=656) and the Radiological Society of North America (RSNA) pulmonary embolism detection challenge 2020 (n=5,303). Additionally, 72 participants were selected from the Klinikum Rechts der Isar dataset (October 2018 to December 2019), each with a corresponding chest radiograph taken within seven days. Synthetic radiographs and lung thickness maps were generated using forward projection of CT scans and their lung segmentations. A U-Net model was trained on synthetic radiographs to predict lung thickness maps and estimate TLV. Model performance was assessed using mean squared error (MSE), Pearson correlation coefficient (r), and two-sided Student's t-distribution. Results: The study included 72 participants (45 male, 27 female, 33 healthy: mean age 62 years [range 34-80]; 39 with chronic obstructive pulmonary disease: mean age 69 years [range 47-91]). TLV predictions showed low error rates ($MSE_{Public-Synthetic}$=0.16 $L^2$, $MSE_{KRI-Synthetic}$=0.20 $L^2$, $MSE_{KRI-Real}$=0.35 $L^2$) and strong correlations with CT-derived reference standard TLV ($n_{Public-Synthetic}$=1,191, r=0.99, P<0.001; $n_{KRI-Synthetic}$=72, r=0.97, P<0.001; $n_{KRI-Real}$=72, r=0.91, P<0.001). The Luna16 test data demonstrated the highest performance, with the lowest mean squared error (MSE = 0.09 $L^2$) and strongest correlation (r = 0.99, P <0.001) for TLV estimation. Conclusion: The U-Net-generated pixel-level lung thickness maps successfully estimated TLV for both synthetic and real radiographs.

eess.IV