Searcharxiv⌕ Search

arXiv subjects

Fotis P. Gavriil

Publications and source records attributed to Fotis P. Gavriil.

25 records · Page 2Linked to original sources

21 years of Timing PSR B1509-58

We present an updated timing solution for the young, energetic pulsar PSR B1509-58 based on 21.3 years of radio timing data and 7.6 years of X-ray timing data. No glitches have occurred in this time span, in contrast to other well-studied young pulsars, which show frequent glitches. We report a measurement of the third frequency derivative of (-1.28+/-0.21)x10^(-31) s^(-4). This value is 1.65 standard deviations from, i.e. consistent with, that predicted by the simple constant magnetic dipole model of pulsar spin-down. We measured the braking index to be n=2.839+/-0.003 and show that it varies by 1.5% over 21.3 yr due to contamination from timing noise. Results of a low-resolution power spectral analysis of the significant noise apparent in the data yield a spectral index of alpha=-4.6+/-1.0 for the red noise component.

astro-ph↗

Anomalous X-ray Pulsar 1E 1048.1-5937: Pulsed Flux Flares and Large Torque Variations

We report on continued monitoring of the Anomalous X-ray pulsar (AXP) 1E 1048.1-5937 using the Rossi X-ray Timing Explorer. We confirm that this pulsar has exhibited significant pulsed flux variability. The principal features of this variability are two pulsed X-ray flares. Both flares lasted several months and had well-resolved few-week-long rises. The long rise times of the flares are a phenomenon not previously reported for this class of object. The epochs of the flare peaks were MJD 52,218.8+/-4.5 and 52,444.4+/-7.0. Both flares had shorter rise than fall times. The flares had peak fluxes of 2.21+/-0.16 and 3.00+/-0.13 times the quiescent value. We estimate a total 2-10 keV energy release of ~2.7x10^40 ergs and ~2.8x10^41 ergs for the flares, assuming a distance of 5 kpc. We also report large (factor of ~12) changes to the pulsar's spin-down rate on time scales of weeks to months, shorter than has been reported previously. We find marginal evidence for correlation between the flux and spin-down rate variability, with probability of nonrandom correlation 6%. We discuss the implications of our findings for AXP models.

astro-ph↗

The X-ray Bursts from the Magnetar Candidate 1E 2259+586

We present a statistical analysis of the X-ray bursts observed from the 2002 June 18 outburst of the Anomalous X-ray Pulsar (AXP) 1E 2259+586, observed with the Proportional Counter Array aboard the Rossi X-ray Timing Explorer. We show that the properties of these bursts are similar to those of Soft Gamma-Repeaters (SGRs). The similarities we find are: the burst durations follow a log-normal distribution which peaks at 99 ms, the differential burst fluence distribution is well described by a power law of index -1.7, the burst fluences are positively correlated with the burst durations, the distribution of waiting times is well described by a log-normal distribution of mean 47 s, and the bursts are generally asymmetric with faster rise than fall times. However, we find several quantitative differences between the AXP and SGR bursts. Specifically, there is a correlation of burst phase with pulsed intensity, the AXP bursts we observed exhibit a wider range of durations, the correlation between burst fluence and duration is flatter than for SGRs, the observed AXP bursts are on average less energetic than observed SGR bursts, and the more energetic AXP bursts have the hardest spectra - the opposite of what is seen for SGRs. We conclude that the bursts are sufficiently similar that AXPs and SGRs can be considered united as a source class yet there are some interesting differences that may help determine what physically differentiates the two closely related manifestations of neutron stars.

astro-ph↗

A Comprehensive Study of the X-ray Bursts from the Magnetar Candidate 1E 2259+586

We present a statistical analysis of the X-ray bursts observed from the 2002 June 18 outburst of the Anomalous X-ray Pulsar (AXP) 1E 2259+586, observed with the Proportional Counter Array (PCA) aboard the Rossi X-ray Timing Explorer. We show that the properties of these bursts are similar to those of Soft Gamma-Repeaters (SGRs). The similarities we find are the burst durations follow a log-normal distribution which peaks at 99 ms, the differential burst fluence distribution is well described by a power law of index -1.7, the burst fluences are positively correlated with the burst durations, the distribution of waiting times is well described by a log-normal distribution of mean 47 s, and the bursts are generally asymmetric with faster rise than fall times. However, we find several quantitative differences between the AXP and SGR bursts. Specifically, the AXP bursts we observed exhibit a wider range of durations, the correlation between burst fluence and duration is flatter than for SGRs, the observed AXP bursts are on average less energetic than observed SGR bursts, and the more energetic AXP bursts have the hardest spectra -- the opposite of what is seen for SGRs. We conclude that the bursts are sufficiently similar that AXPs and SGRs can be considered united as a source class yet there are some interesting differences that may help determine what physically differentiates the two closely related manifestations of neutron stars.

astro-ph↗

Long-Term Monitoring of Anomalous X-ray Pulsars

We report on long-term monitoring of anomalous X-ray pulsars (AXPs) using the Rossi X-ray Timing Explorer. Using phase-coherent timing, we find a wide variety of behaviors among the sources, ranging from high stability (in 1E 2259.1+586 and 4U 0142+61), to instabilities so severe that phase-coherent timing is not possible (in 1E 1048.1-5937). We note a correlation in which timing stability in AXPs decreases with increasing spin-down rate. The timing stability of soft gamma repeaters in quiescence is consistent with this trend, which is similar to one seen in radio pulsars. We consider high signal-to-noise ratio average pulse profiles as a function of energy for each AXP, and find a variety of behaviors. We find no large variability in pulse morphology nor in pulsed flux as a function of time.

astro-ph↗

Long-Term RXTE Monitoring of Anomalous X-ray Pulsars

We report on the long-term monitoring of three anomalous X-ray pulsars using the Rossi X-ray Timing Explorer (RXTE). We present a phase-coherent timing ephemeris for 4U 0142+61, and show that it has rotated with high stability over 4.4 yr, with RMS phase deviations of 7% of the pulse period from a simple fit including only $ν$ and $\dotν$. We report on the continued timing stability of 1E 2259.1+586, for which phase coherence has now been maintained over 4.5 yr, as well as on the detection of a significant $\ddotν$ in 1.4 yr of monitoring of RXS J170849.0-400910, consistent with recovery following a glitch. We note a correlation in which timing stability in AXPs decreases with increasing $\dotν$. The timing stability of soft gamma repeaters in quiescence is consistent with this trend, given their large spin-down rates. This trend is similar to one seen in radio pulsars, suggesting a connection between the three populations. We find no large variability in pulse morphology as a function of time. We present high signal-to-noise ratio average pulse profiles for each AXP, and consider them as a function of energy. We find a variety of different behaviors, and consider possible trends in the data. We also find no large variations in pulsed flux, and set 1 $σ$ upper limits of ~20-30% of the mean. Assuming a constant pulsed fraction, either more than one of the AXPs are coincidentally in a much more quiescent state during our RXTE monitoring than in the past, or past claims of large flux variations are incorrect.

astro-ph↗

Long-Term RXTE Monitoring of the Anomalous X-ray Pulsar 1E 1048.1-5937

We report on long-term monitoring of the anomalous X-ray pulsar (AXP) 1E 1048.1-5937 using the Rossi X-ray Timing Explorer (RXTE). The timing behavior of this pulsar is different from that of other AXPs being monitored with RXTE. In particular, we show that the pulsar shows significant deviations from simple spin-down such that phase-coherent timing has not been possible over time spans longer than a few months. We find that the deviations from simple spin down are not consistent with single "glitch" type events, nor are they consistent with radiative precession. We show that in spite of the rotational irregularities, the pulsar exhibits neither pulse profile changes nor large pulsed flux variations. We discuss the implications of our results for AXP models. In the context of the magnetar model, we suggest that 1E 1048.1-5937 may be a transition object between the soft gamma-ray repeater and AXP populations, and the AXP most likely to one day undergo an outburst.

astro-ph↗