Searcharxiv⌕ Search

arXiv subjects

Frédéric Lange

Publications and source records attributed to Frédéric Lange.

5 recordsLinked to original sources

A unified perspective on wavelength selection for molecular composition inference from diffuse spectroscopy

Optical monitoring of living tissue targeting quantification of molecular composition is an active area of research. In the case of broadband spectroscopy, one can attempt to extract molecular, or more precisely, chromophore concentration from a broad-range spectrum of the reflected light. However, selecting the shortest wavelength range sufficient for quantitative optical monitoring remains an open problem. Various wavelength optimization methods are scattered throughout the literature, however, there is no unified view to date. Our work's motivation is to construct a wavelength selection framework by unifying existing selection approaches and propose a novel projection-based method that allows for the pre-identification of a wavelength range that is adequate for the final selection. The framework specifically focuses on proposing different methods that quantify match or mismatch between the chosen light-matter interaction model, defined by the chosen endmembers (e.g. molecular chromophores), and the measured intensity from the spectroscopic data. To evaluate the framework, we perform a retrospective analysis on a broadband spectroscopy dataset of piglets during an induced hypoxia-ischemia state. Overall, we show that our novel projection-based method can be used for band selection, and that existing approaches can be used in conjunction to select an optimal minimal wavelength set that satisfies biophysical model constraints.

physics.optics↗

Hyperspectral imaging solutions for brain tissue metabolic and haemodynamic monitoring: an updated perspective

Since the publication of our review article Hyperspectral imaging solutions for brain tissue metabolic and hemodynamic monitoring: past, current and future developments in 2018, the technological and applicational landscape of the use of hyperspectral imaging (HSI) in brain sciences has evolved and transformed significantly. The number of studies and works where HSI has been deployed in its many forms to map and monitor the haemodynamic and metabolic states of cerebral tissues have grown exponentially, to such a point where an update on the cur-rent state of the art is timely, and we believe would be desirable for both long-term experts in the field, as well as for any new researcher approaching it for the first time. In this commentary, we provide a renewed perspective on the newest and latest developments in brain haemodynamic and metabolic monitoring with HSI over the past eight years. Our hope is that even greater breakthroughs and broader, more numerous novel applications will come forward in the future for the technology, that may benefit from this new overview, as they did from the original one.

physics.med-ph↗

Optimization of continuous-wave NIRS devices for placental monitoring. A simulation study

Near infrared spectroscopy (NIRS) is an optical technique that is widely used to monitor tissue oxygenation. These devices take advantage of the near infrared light to monitor deep tissues like brain, muscle or placenta. In this study, we developed a Monte Carlo framework to evaluate the sensitivity of continuous-wave (CW) NIRS devices for monitoring the placenta which a deep layer in the maternal abdomen. This framework can be used to optimize CW-NIRS acquisition parameters (integration time, source detector separation) before going into clinical applications.

physics.med-ph↗

Redefining spectral unmixing for in-vivo brain tissue analysis from hyperspectral imaging

In this paper, we propose a methodology for extracting molecular tumor biomarkers from hyperspectral imaging (HSI), an emerging technology for intraoperative tissue assessment. To achieve this, we employ spectral unmixing, allowing to decompose the spectral signals recorded by the HSI camera into their constituent molecular components. Traditional unmixing approaches are based on physical models that establish a relationship between tissue molecules and the recorded spectra. However, these methods commonly assume a linear relationship between the spectra and molecular content, which does not capture the whole complexity of light-matter interaction. To address this limitation, we introduce a novel unmixing procedure that allows to take into account non-linear optical effects while preserving the computational benefits of linear spectral unmixing. We validate our methodology on an in-vivo brain tissue HSI dataset and demonstrate that the extracted molecular information leads to superior classification performance.

physics.med-ph↗

A digital instrument simulator to optimize the development of hyperspectral systems: application for intraoperative functional brain mapping

Intraoperative optical imaging is a localization technique for the functional areas of the human brain cortex during neurosurgical procedures. These areas can be assessed by monitoring cerebral hemodynamics and metabolism. A robust quantification of these biomarkers is complicated to perform during neurosurgery due to the critical context of the operating room. In actual devices, the inhomogeneities of the optical properties of exposed brain cortex are poorly taken into consideration, which introduce quantification errors of biomarkers of brain functionality. Moreover, the choice of the best spectral configuration is still based on an empirical approach. We propose a digital instrument simulator to optimize the development of hyperspectral systems. This simulator can provide a realistic modelling of the cerebral cortex and the identification of the optimal wavelengths to monitor cerebral hemodynamics (oxygenated and deoxygenated hemoglobin) and metabolism (oxidized state of cytochromes b, c and cytochrome-c-oxidase). The digital instrument allows the modelling of intensity maps collected by a camera sensor as well as images of pathlength to take into account the inhomogeneities of the optical properties. The optimization procedure helps to identify the best wavelength combination of 18 wavelengths that reduce the quantification errors in HbO2, Hb, oxCCO of 61%, 29% and 82% compared to the gold standard of 121 wavelengths between 780 and 900 nm. The optimization procedure does not help to resolve changes in cytochrome b and c in a significant way but help to better resolve oxCCO changes. We proposed a digital instrument simulator to optimize the development of hyperspectral systems for intraoperative brain mapping studies. This digital instrument simulator and this optimization framework could be used to optimize the design of hyperspectral imaging devices.

physics.med-ph↗