SearcharxivSearch

arXiv subjects

Frank Seifert

Publications and source records attributed to Frank Seifert.

14 recordsLinked to original sources

A Reference System for Open Source Portable Low-Field MRI

Despite its renewed attention, the pathway to point-of-care portable low-field MRI systems remains challenging, limiting adoption across research groups. Incomplete documentation limits reproducibility, causing redesign and complicating cross-system comparison. Moreover, non-standardized testing and characterization complicates ethical approval for clinical studies. We present an open-source reference system for portable low-field MRI designed to support replication, reproducibility, benchmarking, and quantitative comparison. The system is fully open source, based on a ~50 mT permanent magnet, and integrated with a cloud-native acquisition platform. Pulseq-based calibration, characterization, and imaging sequences assessed noise level, eddy currents, image-based SNR, and geometric accuracy. Quantitative T1, T2, and B0 mapping sequences were developed and evaluated against reference values. Initial results from independent replications at two sites were compared. The system reached a noise level of 1.4 relative to the thermal noise floor and short eddy-current decay constants of 27-32 us across all gradient channels. Geometric deviations were below 2 mm over the field of view. Image-based SNR were consistent between the independent replications. Measured T1 values closely matched specified values, with an average absolute error of 3.1(1.8)%, while T2 values were overestimated by 10.4(5.8)%. Simulations showed only marginal errors for both quantities, suggesting experimental error sources for T2 mapping. The reference system combines openly documented hardware, software, calibration procedures, phantoms, quantitative MRI, and simulation tools in a reproducible ecosystem, aiming to support cross-site comparability, reproducible research, and collaborative development of future portable low-field MRI technologies.

physics.med-ph

Flexures for Kibble balances: Minimizing the effects of anelastic relaxation

We studied the anelastic aftereffect of a flexure being used in a Kibble balance, where the flexure is subjected to a large excursion in velocity mode after which a high-precision force comparison is performed. We investigated the effect of a constant and a sinusoidal excursion on the force comparison. We explored theoretically and experimentally a simple erasing procedure, i.e., bending the flexure in the opposite direction for a given amplitude and time. We found that the erasing procedure reduced the time-dependent force by about 30%. The investigation was performed with an analytical model and verified experimentally with our new Kibble balance at the National Institute of Standards and Technology employing flexures made from precipitation-hardened Copper Beryllium alloy C17200. Our experimental determination of the modulus defect of the flexure yields 1.2E-4. This result is about a factor of two higher than previously reported from experiments. We additionally found a static shift of the flexure's internal equilibrium after a change in the stress and strain state. These static shifts, although measurable, are small and deemed uncritical for our Kibble balance application at present. During this investigation, we discovered magic flexures that promise to have very little anelastic relaxation. In these magic flexures, the mechanism causing anelastic relaxation is compensated for by properly shaping and loading a flexure with a non-constant cross-section in the region of bending.

physics.class-ph

Calculation of magnetic forces and torques on the Kibble coil

Analytically the forces and torques on a coil in a field of magnetic flux density can be calculated one of two ways. The line integral can be conducted along the coil's wire, summing up the differential force contribution. For each differential line segment, the force is obtained as a cross product with the magnetic flux density. Alternatively, the coil's energy in the field is the current times the flux threading the coil. Hence, the energy is obtained by executing a surface integral over the coil's open surface. Here, a dot product of the differential surface element with the magnetic flux density is executed under the integral sign. The forces and torques can then be obtained from the negative derivative of the energy with respect to the appropriate coordinate. For yoke-based Kibble balances, the latter method is much simpler since most of the flux is contained in the inner yoke of the magnet and can be written as a simple equation. Here, we use this method to provide simple equations and their results for finding the torques and forces that act on a coil in a yoke-based magnet system. We further introduce a simple method that allows the calculation of the position and orientation difference between the coil and the magnet from three measurements.

physics.ins-det

Conception of an enhanced mechanism for a new Kibble balance directly traceable to the quantum SI

The ``Quantum Electro-Mechanical Metrology Suite'' (QEMMS) is being designed and built at the National Institute of Standards and Technology. It includes a Kibble balance, a Graphene quantum Hall resistance array and a Josephson voltage system, so that it is a new primary standard for the unit of mass, the kilogram, directly traceable to the International System of Units (SI) based on quantum constants. We are targeting a measurement range of 10 g to 200 g and optimize the design for a relative combined uncertainty of $2\times 10^{-8}$ for masses of 100 g. QEMMS will be developed as an open hardware and software design. In this article, we explain the design of the moving and weighing mechanism in the QEMMS.

physics.ins-det

Resolution of the paradox of the diamagnetic effect on the Kibble coil

Employing very simple electro-mechanical principles known from classical physics, the Kibble balance establishes a very precise and absolute link between quantum electrical standards and macroscopic mass or force measurements. The success of the Kibble balance, in both determining fundamental constants ($h$, $N_A$, $e$) and realizing a quasi-quantum mass in the 2019 newly revised International System of Units, relies on the perfection of Maxwell's equations and the symmetry they describe between Lorentz's force and Faraday's induction, a principle and a symmetry stunningly demonstrated in the weighing and velocity modes of Kibble balances to within $1\times10^{-8}$, with nothing but imperfect wires and magnets. However, recent advances in the understanding of the current effect in Kibble balances reveal a troubling paradox. A diamagnetic effect, a force that does not cancel between mass-on and mass-off measurement, is challenging balance maker's assumptions of symmetry at levels that are almost two orders of magnitude larger than the reported uncertainties. The diamagnetic effect, if it exists, shows up in weighing mode without a readily apparent reciprocal effect in the velocity mode, begging questions about systematic errors at the very foundation of the new measurement system. The hypothetical force is caused by the coil current changing the magnetic field, producing an unaccounted force that is systematically modulated with the weighing current. Here we show that this diamagnetic force exists, but the additional force does not change the equivalence between weighing and velocity measurements. We reveal the unexpected way that symmetry is preserved and show that for typical materials and geometries the total relative effect on the measurement is $\approx 1\times10^{-9}$.

physics.ins-det

A Cryogenic Silicon Interferometer for Gravitational-wave Detection

The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.

astro-ph.IM

Magnet system for the Quantum Electro-Mechanical Metrology Suite

The design of the permanent magnet system for the new Quantum Electro-Mechanical Metrology Suite (QEMMS) is described. The QEMMS, developed at the National Institute of Standards and Technology (NIST), consists of a Kibble balance, a programmable Josephson voltage standard, and a quantum Hall resistance standard. It will be used to measure masses up to $100\,\mathrm{g}$ with relative uncertainties below $2\times 10^{-8}$. The magnet system is based on the design of the NIST-4 magnet system with significant changes to adopt to a smaller Kibble balance and to overcome known practical limitations. Analytical models are provided to describe the coil-current effect and model the forces required to split the magnet in two parts to install the coil. Both models are compared to simulation results obtained with finite element analysis and measurement results. Other aspects, such as the coil design and flatness of $Bl$ profile are considered.

physics.ins-det

The Performance of the KIBB-g1 Tabletop Kibble Balance at NIST

A tabletop-sized Kibble balance (KIBB-g1) designed to directly realize mass at the gram-level range with uncertainties on the order of parts in 10$^6$ has been developed at the National Institute of Standards and Technology (NIST). The masses of a nominally 5\,g and 1\,g weight were determined with 1-$σ$ standard uncertainties of 9.0\,$\upmu$g and 6.7\,$\upmu$g, respectively. The corresponding relative uncertainties are $1.8\times 10^{-6}$ and $6.3\times 10^{-6}$. The construction of the instrument, capabilities, and full uncertainty budgets are presented in this manuscript.

physics.ins-det

MPX Detectors as LHC Luminosity Monitor

A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It was designed to measure the composition and spectral characteristics of the radiation field in the ATLAS experiment and its surroundings. This study demonstrates that the MPX network can also be used as a self-sufficient luminosity monitoring system. The MPX detectors collect data independently of the ATLAS data-recording chain, and thus they provide independent measurements of the bunch-integrated ATLAS/LHC luminosity. In particular, the MPX detectors located close enough to the primary interaction point are used to perform van der Meer calibration scans with high precision. Results from the luminosity monitoring are presented for 2012 data taken at sqrt(s) = 8 TeV proton-proton collisions. The characteristics of the LHC luminosity reduction rate are studied and the effects of beam-beam (burn-off) and beam-gas (single bunch) interactions are evaluated. The systematic variations observed in the MPX luminosity measurements are below 0.3% for one minute intervals.

physics.ins-det

Coherent Cancellation of Photothermal Noise in GaAs/Al$_{0.92}$Ga$_{0.08}$As Bragg Mirrors

Thermal noise is a limiting factor in many high-precision optical experiments. A search is underway for novel optical materials with reduced thermal noise. One such pair of materials, gallium arsenide and aluminum-alloyed gallium arsenide (collectively referred to as AlGaAs), shows promise for its low Brownian noise when compared to conventional materials such as silica and tantala. However, AlGaAs has the potential to produce a high level of thermo-optic noise. We have fabricated a set of AlGaAs crystalline coatings, transferred to fused silica substrates, whose layer structure has been optimized to reduce thermo-optic noise by inducing coherent cancellation of the thermoelastic and thermorefractive effects. By measuring the photothermal transfer function of these mirrors, we find evidence that this optimization has been successful.

physics.optics

Construction, Measurement, Shimming, and Performance of the NIST-4 Magnet System

The magnet system is one of the key elements of a watt balance. For the new watt balance currently under construction at the National Institute of Standards and Technology, a permanent magnet system was chosen. We describe the detailed construction of the magnet system, first measurements of the field profile, and shimming techniques that were used to achieve a flat field profile. The relative change of the radial magnetic flux density is less than $10^{-4}$ over a range of 5 cm. We further characterize the most important aspects of the magnet and give order of magnitude estimates for several systematic effects that originate from the magnet system.

physics.ins-det

Broadband Measurement of Coating Thermal Noise in Rigid Fabry-Perot Cavities

We report on the relative length fluctuation of two fixed-spacer Fabry-Perot cavities with mirrors fabricated from silica/tantala dielectric coatings on fused silica substrates. By locking a laser to each cavity and reading out the beat note $\hatν = ν_1 - ν_2$ of the transmitted beams, we find that, for frequencies from 10 Hz to 1 kHz, the amplitude spectral density of beat note fluctuation is $\sqrt{S_\hatν(f)} = (0.5\,\mathrm{Hz})/f^{1/2}$. By careful budgeting of noise sources contributing to the beat note, we find that our measurement is consistent with the fluctuation in this band being dominated by the Brownian noise of the mirror coatings. Fitting for the coating loss angle $ϕ_\mathrm{c}$, we find it equal to $4\times10^{-4}$. We then use a Bayesian analysis to combine our measurement with previous observations, and thereby extract estimates for the individual loss angles of silica and tantala. It is hoped that the testbed described in this article can be used in the future to measure the length noise of cavities formed with novel mirror materials and geometries.

physics.optics

Determination of the Planck constant using a watt balance with a superconducting magnet system at the National Institute of Standards and Technology

For the past two years, measurements have been performed with a watt balance at the National Institute of Standards and Technology (NIST) to determine the Planck constant. A detailed analysis of these measurements and their uncertainties has led to the value $h=6.626\,069\,79(30)\times 10^{-34}\,$J$\,$s. The relative standard uncertainty is $ 45\times 10^{-9}$. This result is $141\times 10^{-9}$ fractionally higher than $h_{90}$. Here $h_{90}$ is the conventional value of the Planck constant given by $h_{90}\equiv 4 /( K_{\mathrm{J-90}}^2R_{\mathrm{K-90}})$, where $K_{\mathrm{J-90}}$ and $R_{\mathrm{K-90}}$ denote the conventional values of the Josephson and von Klitzing constants, respectively.

physics.class-ph

Constraints on Spin-Dependent Short-Range Interaction between Nucleons

We report on the search for a new spin-dependent P- and T-violating interaction between nucleons mediated by light, pseudoscalar bosons such as the axion which was invented to solve the strong CP problem. Our experimental approach is to use an ultra-sensitive low-field magnetometer based on the detection of free precession of co-located 3He and 129Xe nuclear spins using SQUIDs as low-noise magnetic flux detectors. In the presence of an unpolarized mass the precession frequency shif

hep-ex