Searcharxiv⌕ Search

arXiv subjects

Fredrik Rantakyrö

Publications and source records attributed to Fredrik Rantakyrö.

11 recordsLinked to original sources

GOATS: The next generation software infrastructure for time-domain astronomy at Gemini/NOIRLab. Application to alerts from Vera C. Rubin Observatory's Legacy Survey of Space and Time

Time-domain and multimessenger astronomy (MMA/TDA) targets demand rapid-response follow-up observations. In many cases, it is the only way to make discoveries and advance our understanding of the astrophysical phenomena, for example, kilonovae accompanying gravitational waves from compact object mergers, shock breakout in supernovae, prompt emission from GRBs, etc. Presently the MMA/TDA follow-up workflow requires wrangling disparate software packages and user interfaces. We present an end-to-end software tool for the community, the Gemini Observation and Analysis of Targets System (GOATS), which unifies and simplifies the workflow, particularly for Gemini follow-up observations. GOATS achieves this by integrating services from Gemini Observatory and its parent organization, NSF NOIRLab. From a single platform, GOATS enables enhanced target selection via NOIRLab's ANTARES alert broker, triggering of Gemini (and other facilities within the Astronomical Event Observatory Network), automated data retrieval from the Gemini Observatory Archive, and interactive data reduction and analysis through Gemini's DRAGONS software and NOIRLab's Astro Data Lab science platform. GOATS was successfully deployed in an end-to-end demonstration of real-time follow-up of Rubin/LSST alerts with NOIRLab facilities. As part of this demonstration, we selected targets from the Rubin alert stream and triggered follow-up observations within minutes of the Rubin detections. We obtained spectra for several targets and classified them as supernova of various types (Ia, IIP, Ib/c) with redshifts ranging from 0.05 to 0.35. By eliminating the need to manually connect tools and automating repetitive tasks, GOATS lowers the entry barrier and allows users to focus on the scientific interpretation of the observation results.

astro-ph.IM↗

GPI 2.0: Exploring The Impact of Different Readout Modes on the Wavefront Sensor's EMCCD

The Gemini Planet Imager (GPI) is a high contrast imaging instrument that aims to detect and characterize extrasolar planets. GPI is being upgraded to GPI 2.0, with several subsystems receiving a re-design to improve its contrast. To enable observations on fainter targets and increase performance on brighter ones, one of the upgrades is to the adaptive optics system. The current Shack-Hartmann wavefront sensor (WFS) is being replaced by a pyramid WFS with an low-noise electron multiplying CCD (EMCCD). EMCCDs are detectors capable of counting single photon events at high speed and high sensitivity. In this work, we characterize the performance of the HNü 240 EMCCD from Nüvü Cameras, which was custom-built for GPI 2.0. Through our performance evaluation we found that the operating mode of the camera had to be changed from inverted-mode (IMO) to non-inverted mode (NIMO) in order to improve charge diffusion features found in the detector's images. Here, we characterize the EMCCD's noise contributors (readout noise, clock-induced charges, dark current) and linearity tests (EM gain, exposure time) before and after the switch to NIMO.

astro-ph.IM↗

GPI 2.0: Performance Evaluation of the Wavefront Sensor's EMCCD

The Gemini Planet Imager (GPI) is a high contrast imaging instrument that aims to detect and characterize extrasolar planets. GPI is being upgraded to GPI 2.0, with several subsystems receiving a re-design to improve the instrument's contrast. To enable observations on fainter targets and increase stability on brighter ones, one of the upgrades is to the adaptive optics system. The current Shack-Hartmann wavefront sensor (WFS) is being replaced by a pyramid WFS with an low-noise electron multiplying CCD (EMCCD). EMCCDs are detectors capable of counting single photon events at high speed and high sensitivity. In this work, we characterize the performance of the HNü 240 EMCCD from Nüvü Cameras, which was custom-built for GPI 2.0. The HNü 240 EMCCD's characteristics make it well suited for extreme AO: it has low dark current ($<$ 0.01 e-/pix/fr), low readout noise (0.1 e-/pix/fr at a gain of 5000), high quantum efficiency ( 90% at wavelengths from 600-800 nm; 70% from 800-900 nm), and fast readout (up to 3000 fps full frame). Here we present test results on the EMCCD's noise contributors, such as the readout noise, pixel-to-pixel variability and CCD bias. We also tested the linearity and EM gain calibration of the detector. All camera tests were conducted before its integration into the GPI 2.0 PWFS system.

astro-ph.IM↗

Automated data processing architecture for the Gemini Planet Imager Exoplanet Survey

The Gemini Planet Imager Exoplanet Survey (GPIES) is a multi-year direct imaging survey of 600 stars to discover and characterize young Jovian exoplanets and their environments. We have developed an automated data architecture to process and index all data related to the survey uniformly. An automated and flexible data processing framework, which we term the Data Cruncher, combines multiple data reduction pipelines together to process all spectroscopic, polarimetric, and calibration data taken with GPIES. With no human intervention, fully reduced and calibrated data products are available less than an hour after the data are taken to expedite follow-up on potential objects of interest. The Data Cruncher can run on a supercomputer to reprocess all GPIES data in a single day as improvements are made to our data reduction pipelines. A backend MySQL database indexes all files, which are synced to the cloud, and a front-end web server allows for easy browsing of all files associated with GPIES. To help observers, quicklook displays show reduced data as they are processed in real-time, and chatbots on Slack post observing information as well as reduced data products. Together, the GPIES automated data processing architecture reduces our workload, provides real-time data reduction, optimizes our observing strategy, and maintains a homogeneously reduced dataset to study planet occurrence and instrument performance.

astro-ph.IM↗

The First H-band Spectrum of the Massive Gas Giant Planet beta Pictoris b with the Gemini Planet Imager

Using the recently installed Gemini Planet Imager (GPI), we have taken the first H-band spectrum of the planetary companion to the nearby young star beta Pictoris. GPI is designed to image and provide low-resolution spectra of Jupiter sized, self-luminous planetary companions around young nearby stars. These observations were taken covering the H-band (1.65 microns). The spectrum has a resolving power of $\sim$ 45 and demonstrates the distinctive triangular shape of a cool substellar object with low surface gravity. Using atmospheric models, we find an effective temperature of $1650 \pm 50$ K and a surface gravity of $\log(g) = 4.0 \pm 0.25$ (cgs units). These values agree well with predictions from planetary evolution models for a gas giant with mass between 10 and 12 $M_{\rm Jup}$ and age between 10 and 20 Myrs.

astro-ph.EP↗

Characterization of the Atmospheric Dispersion Corrector of the Gemini Planet Imager

An Atmospheric Dispersion Corrector (ADC) uses a double-prism arrangement to nullify the vertical chromatic dispersion introduced by the atmosphere at non-zero zenith distances. The ADC installed in the Gemini Planet Imager (GPI) was first tested in August 2012 while the instrument was in the laboratory. GPI was installed at the Gemini South telescope in August 2013 and first light occurred later that year on November 11th. In this paper, we give an overview of the characterizations and performance of this ADC unit obtained in the laboratory and on sky, as well as the structure of its control software.

astro-ph.IM↗

Automated Alignment and On-Sky Performance of the Gemini Planet Imager Coronagraph

The Gemini Planet Imager (GPI) is a next-generation, facility instrument currently being commissioned at the Gemini South observatory. GPI combines an extreme adaptive optics system and integral field spectrograph (IFS) with an apodized-pupil Lyot coronagraph (APLC) producing an unprecedented capability for directly imaging and spectroscopically characterizing extrasolar planets. GPI's operating goal of $10^{-7}$ contrast requires very precise alignments between the various elements of the coronagraph (two pupil masks and one focal plane mask) and active control of the beam path throughout the instrument. Here, we describe the techniques used to automatically align GPI and maintain the alignment throughout the course of science observations. We discuss the particular challenges of maintaining precision alignments on a Cassegrain mounted instrument and strategies that we have developed that allow GPI to achieve high contrast even in poor seeing conditions.

astro-ph.IM↗

Gemini Planet imager Observational Calibrations X: Non-Redundant Masking on GPI

The Gemini Planet Imager (GPI) Extreme Adaptive Optics Coronograph contains an interferometric mode: a 10-hole non-redundant mask (NRM) in its pupil wheel. GPI operates at $Y, J, H$, and $K$ bands, using an integral field unit spectrograph (IFS) to obtain spectral data at every image pixel. NRM on GPI is capable of imaging with a half resolution element inner working angle at moderate contrast, probing the region behind the coronagraphic spot. The fine features of the NRM PSF can provide a reliable check on the plate scale, while also acting as an attenuator for spectral standard calibrators that would otherwise saturate the full pupil. NRM commissioning data provides details about wavefront error in the optics as well as operations of adaptive optics control without pointing control from the calibration system. We compare lab and on-sky results to evaluate systematic instrument properties and examine the stability data in consecutive exposures. We discuss early on-sky performance, comparing images from integration and tests with the first on-sky images, and demonstrate resolving a known binary. We discuss the status of NRM and implications for future science with this mode.

astro-ph.IM↗

The Integral Field Spectrograph for the Gemini Planet Imager

The Gemini Planet Imager (GPI) is a complex optical system designed to directly detect the self-emission of young planets within two arcseconds of their host stars. After suppressing the starlight with an advanced AO system and apodized coronagraph, the dominant residual contamination in the focal plane are speckles from the atmosphere and optical surfaces. Since speckles are diffractive in nature their positions in the field are strongly wavelength dependent, while an actual companion planet will remain at fixed separation. By comparing multiple images at different wavelengths taken simultaneously, we can freeze the speckle pattern and extract the planet light adding an order of magnitude of contrast. To achieve a bandpass of 20%, sufficient to perform speckle suppression, and to observe the entire two arcsecond field of view at diffraction limited sampling, we designed and built an integral field spectrograph with extremely low wavefront error and almost no chromatic aberration. The spectrograph is fully cryogenic and operates in the wavelength range 1 to 2.4 microns with five selectable filters. A prism is used to produce a spectral resolution of 45 in the primary detection band and maintain high throughput. Based on the OSIRIS spectrograph at Keck, we selected to use a lenslet-based spectrograph to achieve an rms wavefront error of approximately 25 nm. Over 36,000 spectra are taken simultaneously and reassembled into image cubes that have roughly 192x192 spatial elements and contain between 11 and 20 spectral channels. The primary dispersion prism can be replaced with a Wollaston prism for dual polarization measurements. The spectrograph also has a pupil-viewing mode for alignment and calibration.

astro-ph.IM↗

Gemini Planet Imager Observational Calibrations VII: On-Sky Polarimetric Performance of the Gemini Planet Imager

We present on-sky polarimetric observations with the Gemini Planet Imager (GPI) obtained at straight Cassegrain focus on the Gemini South 8-m telescope. Observations of polarimetric calibrator stars, ranging from nearly unpolarized to strongly polarized, enable determination of the combined telescope and instrumental polarization. We find the conversion of Stokes $I$ to linear and circular instrumental polarization in the instrument frame to be $I \rightarrow (Q_{\rm IP}, U_{\rm IP}, P_{\rm IP}, V_{\rm IP}) = (-0.037 \pm 0.010\%, +0.4338 \pm 0.0075\%, 0.4354 \pm 0.0075\%, -6.64 \pm 0.56\%)$. Such precise measurement of instrumental polarization enables $\sim 0.1\%$ absolute accuracy in measurements of linear polarization, which together with GPI's high contrast will allow GPI to explore scattered light from circumstellar disk in unprecedented detail, conduct observations of a range of other astronomical bodies, and potentially even study polarized thermal emission from young exoplanets. Observations of unpolarized standard stars also let us quantify how well GPI's differential polarimetry mode can suppress the stellar PSF halo. We show that GPI polarimetry achieves cancellation of unpolarized starlight by factors of 100-200, reaching the photon noise limit for sensitivity to circumstellar scattered light for all but the smallest separations at which the calibration for instrumental polarization currently sets the limit.

astro-ph.IM↗

Effects of differential wavefront sensor bias drifts on high contrast imaging

The Gemini Planet Imager (GPI) is a new facility, extreme adaptive optics (AO), coronagraphic instrument, currently being integrated onto the 8-meter Gemini South telescope, with the ultimate goal of directly imaging extrasolar planets. To achieve the contrast required for the desired science, it is necessary to quantify and mitigate wavefront error (WFE). A large source of potential static WFE arises from the primary AO wavefront sensor (WFS) detector's use of multiple readout segments with independent signal chains including on-chip preamplifiers and external amplifiers. Temperature changes within GPI's electronics cause drifts in readout segments' bias levels, inducing an RMS WFE of 1.1 nm and 41.9 nm over 4.44 degrees Celsius, for magnitude 4 and 11 stars, respectively. With a goal of $<$2 nm of static WFE, these are significant enough to require remedial action. Simulations imply a requirement to take fresh WFS darks every 2 degrees Celsius of temperature change, for a magnitude 6 star; similarly, for a magnitude 7 star, every 1 degree Celsius of temperature change. For sufficiently dim stars, bias drifts exceed the signal, causing a large initial WFE, and the former periodic requirement practically becomes an instantaneous/continuous one, making the goal of $<$2 nm of static WFE very difficult for stars of magnitude 9 or fainter. In extreme cases, this can cause the AO loops to destabilize due to perceived nonphysical wavefronts, as some of the WFS's Shack-Hartmann quadcells are split between multiple readout segments. Presented here is GPI's AO WFS geometry, along with detailed steps in the simulation used to quantify bias drift related WFE, followed by laboratory and on sky results, and concluded with possible methods of remediation.

astro-ph.IM↗