Dual-Tuned 31P-1H Dual-Row Loop/Dipole 32-element Transceiver Array for Human Brain Spectroscopy at 9.4T

Purpose The goal of this work is to develop and evaluate a single-layer tight-fit 32-element double-tuned loop/dipole transceiver (TxRx) array for human brain 31P MRS at 9.4T, achieving reasonable transmit and receive performance and full-brain coverage at both frequencies. Methods First, we developed numerical models of dual-row TxRx arrays for 31P (loop array) and 1H (coaxial-end folded-end dipole array) frequencies at 9.4T. Next, a multi-tissue voxel model was used to simulate Tx-performance of the arrays and define optimal CP-mode excitation. Following this, the proposed array performance was evaluated by MR measurements both on a phantom and a healthy volunteer. Finally, we compared the proposed array to a previously reported dual-tuned single-row loop-based TxRx array. Results The developed 32-element double-tuned array demonstrated full-brain (including the cerebellum and brain stem) imaging capabilities, reasonable SNR and transmit performance at both frequencies at 9.4T. Conclusion As a proof of concept, we developed a 32-element double-tuned UHF tight-fit TxRx human head array coil for 31P MRS with sufficient 1H performance using a combination of loop and dipole array elements. The proposed array design could also be adapted to higher fields, i.e., 10.5T, 11.7T, and 14T.

physics.app-ph

RF-coil with variable resonant frequency for multiheteronuclear ultra-high field MRI

Here we propose double-coil setup to allow high signal-to-noise ratio broad-range heteronuclear magnetic resonance imaging experiments: two independent coils, one of them tuned to $^{1}$H frequency to perform anatomical $^{1}$H imaging, and another one, metamaterial-inspired coil, tuned to the X-nucleus frequency. In this work our goal was to design a broad-range X-nuclei coil to cover $^{2}$H, $^{11}$B, $^{13}$C, $^{23}$Na, $^{7}$Li and $^{31}$P nuclear magnetic resonance frequencies, and to combine it with $^{1}$H coil in one setup. The system was designed for 11.7 T scanner, i.e., with 76-203 MHz frequency tuning range for the X-nuclei and tuned to 500 MHz for the proton coil. X-nuclei coil operates via excitation of the fundamental eigenmode of an array of parallel non-magnetic wires. The excitation of the array is provided via non-resonant feeding loop inductively coupled to the resonator. In order to tune the X-coil over such a wide range, both structural capacitance and inductance of the coil were made variable; narrow range tuning of the $^{1}$H coil is achieved via conventional tuning-matching circuit. Here, the design principle and setup tunability were investigated in simulations and experimentally.

physics.med-ph