SearcharxivSearch

arXiv subjects

G. Atoian

Publications and source records attributed to G. Atoian.

9 recordsLinked to original sources

Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the Electron-Ion Collider

We analyze beam-induced depolarizing effects in the hydrogen jet target (HJET) at the Relativistic Heavy Ion Collider (RHIC) that has been used for absolute hadron beam polarimetry and shall be employed at the Electron-Ion Collider (EIC). The EIC's higher bunch repetition frequencies and shorter bunch durations shift beam harmonics to frequencies that can resonantly drive hyperfine transitions in hydrogen, threatening to depolarize the target atoms. Using frequency-domain analysis of beam harmonics and hyperfine transition frequencies, we establish a photon emission threshold above which beam-induced fields are too weak to cause significant depolarization. For EIC injection (\SI{23.5}{\GeV}) and flattop (\SI{275}{\GeV}), beam-induced depolarization through the bunch structure renders operation at the current RHIC magnetic guide field at the target of $B_0 = \SI{120}{\milli\tesla}$ untenable. Increasing the magnetic guide field at the target to $B_0 \approx \SI{400}{\milli\tesla}$ moves all hyperfine transition frequencies to at least three times the cutoff frequency, ensuring reliable absolute beam polarimetry with the required 1\% precision at the EIC.

physics.acc-ph

Optically Pumped Polarized $^3$He$^{++}$ Ion Source Development for RHIC/EIC

The proposed polarized $^3$He$^{++}$ acceleration in RHIC and the future Electron-Ion Collider will require about $2\times10^{11}$ ions in the source pulse. A new technique had been proposed for production of high intensity polarized $^3$He$^{++}$ ion beams. It is based on ionization and accumulation of the $^3$He gas (polarized by metastability-exchange optical pumping and in the 5 T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel $^3$He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized $^3$He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3--5 T field has been developed. The $^3$He polarization 80--85\% (and sufficiently long $\sim30$ min relaxation time) was obtained in the \lq\lq{open}\rq\rq\ cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and $^3$He $^4$He absolute nuclear polarimeter at 6 MeV $^3$He$^{++}$ beam energy is also presented.

physics.ins-det

Precision small scattering angle measurements of proton-proton and proton-nucleus analyzing powers at the RHIC hydrogen jet polarimeter

At RHIC, the hydrogen jet target polarimeter (HJET) is used to measure proton beam polarization with accuracy $σ_P^\text{syst}/P\lesssim0.5\%$ by counting low energy (1--10 MeV) recoil protons in left-right symmetric detectors. The HJET performance also allowed us to precisely measure $pp$ and $p$A (where A is any ion stored at RHIC) analyzing powers in the CNI region. The results of the measurements are discussed.

hep-ex

On the possibility of measuring the polarization of a ${}^3\rm{He}$ beam at EIC by the HJET polarimeter

The requirements for hadron polarimetry at the future Electron Ion Collider (EIC) include measurements of the absolute helion (${}^3\text{He}$, $h$) beam polarization with systematic uncertainties better than $σ^\text{syst}_P/P\lesssim1\%$. Here, we consider a possibility to utilize the Polarized Atomic Hydrogen Gas Jet Target (HJET) for precision measurement of polarization of the $\sim$100 GeV/n helion beam. HJET, which serves to determine absolute proton beam polarization at the Relativistic Heavy Ion Collider, provides the accuracy of about $δ^\text{syst}P/P\sim0.5\%$. Potential problems for adapting the HJET method for the EIC helion beam include (i) necessity to know the ratio of $p^\uparrow{h}$ and $h^\uparrow{p}$ analyzing powers $A_\text{N}^{ph}(t)/A_\text{N}^{hp}(t)$ with high precision, ({ii) possible beam ${}^3\text{He}$ breakup, and (iii) operation in a 10 ns bunch spacing beam. Preliminary results of an analysis discussed here indicate that the listed problems can be overcome and the helion beam absolute polarization can be measured by HJET with the required accuracy.

hep-ph

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 ($E_\text{beam}\!=\!100~\text{GeV}$) and 17 ($255~\text{GeV}$). For a typical 8 hour RHIC store, the measured proton beam average polarization was about $P_\text{beam}\!\sim\!55\pm2.0_\text{stat}\pm0.3_\text{syst}\%$. The elastic $\mathit{pp}$ analyzing power, $A_\text{N}(t)\!\sim\!0.04$, was determined with a precision of about $|δA_\text{N}(t)|\!\sim\!0.0002$ in the momentum transfer squared range $0.001\!<\!-t\!<\!0.020\,\text{GeV}^2$. In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

physics.ins-det

Precision Small Scattering Angle Measurements of Elastic Proton-Proton Single and Double Spin Analyzing Powers at the RHIC Hydrogen Jet Polarimeter

The Polarized Atomic Hydrogen Gas Jet Target polarimeter is employed by the Relativistic Heavy Ion Collider (RHIC) to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase solid angle, energy range and energy resolution. These upgrades and advanced systematic error analysis along with improved beam intensity and polarization in RHIC runs 2015 ($E_\textrm{beam}=100\,\text{GeV}$) and 2017 ($255\,\text{GeV}$) allowed us to greatly reduce the statistical and systematic uncertainties for elastic spin asymmetries, $A_N(t)$ and $A_NN(t)$, in the Coulomb-nuclear interference momentum transfer range $0.0013<-t<0.018\,\text{GeV}^2$. For the first time hadronic single spin-flip $r_5$ and double spin-flip $r_2$ amplitude parameters were reliably isolated at these energies and momentum transfers. Measurements at two beam energies enable a separation of Pomeron and Regge pole contributions to $r_5(s)$ and $r_2(s)$, indicating that the spin component may persist at high energies.

hep-ex

Enhanced Polarization of Low Pressure $^3$He through Metastability-Exchange Optical Pumping at High Field

We report high steady-state nuclear polarization of 1 torr $^3$He gas nuclei via metastability-exchange optical pumping at magnetic fields above 2 T. The introduction of highly polarized $^3$He gas into Brookhaven's Electron Beam Ion Source would enable a new, polarized $^3$He ion source for use at the Relativistic Heavy Ion Collider and a future Electron-Ion Collider facility. By adapting recent developments in high field metastability-exchange optical pumping for higher pressure gas, we have successfully polarized 1 torr $^3$He sealed cells in the EBIS solenoid. Through careful manipulation of the RF discharge parameters, polarizations above 80% were attained at 2, 3 and 4 T, with 89% being reached at 3 T with a 664 s relaxation time.

physics.ins-det

Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.

hep-ex

The FP420 R&D Project: Higgs and New Physics with forward protons at the LHC

We present the FP420 R&D project, which has been studying the key aspects of the development and installation of a silicon tracker and fast-timing detectors in the LHC tunnel at 420 m from the interaction points of the ATLAS and CMS experiments. These detectors would measure precisely very forward protons in conjunction with the corresponding central detectors as a means to study Standard Model (SM) physics, and to search for and characterise New Physics signals. This report includes a detailed description of the physics case for the detector and, in particular, for the measurement of Central Exclusive Production, pp --> p + phi + p, in which the outgoing protons remain intact and the central system phi may be a single particle such as a SM or MSSM Higgs boson. Other physics topics discussed are gamma-gamma and gamma-p interactions, and diffractive processes. The report includes a detailed study of the trigger strategy, acceptance, reconstruction efficiencies, and expected yields for a particular p p --> p H p measurement with Higgs boson decay in the b-bbar mode. The document also describes the detector acceptance as given by the LHC beam optics between the interaction points and the FP420 location, the machine backgrounds, the new proposed connection cryostat and the moving ("Hamburg") beam-pipe at 420 m, and the radio-frequency impact of the design on the LHC. The last part of the document is devoted to a description of the 3D silicon sensors and associated tracking performances, the design of two fast-timing detectors capable of accurate vertex reconstruction for background rejection at high-luminosities, and the detector alignment and calibration strategy.

hep-ex