Searcharxiv⌕ Search

arXiv subjects

G. B. Franklin

Publications and source records attributed to G. B. Franklin.

At least 37 records · Page 2Linked to original sources

First transmission of electrons and ions through the KATRIN beamline

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.

physics.ins-det↗

The KATRIN Superconducting Magnets: Overview and First Performance Results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064~m to 9~m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70$\%$ of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01$\%$ per month at 70$\%$ of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

physics.ins-det↗

Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.

physics.ins-det↗

Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment

The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.

physics.ins-det↗

Measurements of $d_{2}^{n}$ and $A_{1}^{n}$: Probing the neutron spin structure

We report on the results of the E06-014 experiment performed at Jefferson Lab in Hall A, where a precision measurement of the twist-3 matrix element $d_2$ of the neutron ($d_{2}^{n}$) was conducted. This quantity represents the average color Lorentz force a struck quark experiences in a deep inelastic electron scattering event off a neutron due to its interaction with the hadronizing remnants. This color force was determined from a linear combination of the third moments of the spin structure functions $g_1$ and $g_2$ on $^{3}$He after nuclear corrections had been applied to these moments. The kinematics included two average $Q^{2}$ bins of $3.2$ GeV$^{2}$ and $4.3$ GeV$^{2}$, and Bjorken-$x$ $0.25 \leq x \leq 0.90$ covering the DIS and resonance regions. We found $d_2^n$ to be small and negative for $ = 3.2$ GeV$^{2}$, and smaller for $ = 4.3$ GeV$^{2}$, consistent with a lattice QCD calculation. The twist-4 matrix element $f_{2}^{n}$ was extracted by combining our $d_{2}^{n}$ with the world data on $Γ_{1}^{n} = \int_{0}^{1} g_{1}^{n} dx$. We found $f_{2}^{n}$ to be roughly an order of magnitude larger than $d_{2}^{n}$. Utilizing the extracted $d_{2}^{n}$ and $f_{2}^{n}$ data, we separated the color force into its electric and magnetic components, $F_{E}^{y,n}$ and $F_{B}^{y,n}$, and found them to be equal and opposite in magnitude, in agreement with instanton model predictions but not with those from QCD sum rules. Additionally, we have extracted the neutron virtual photon-nucleon asymmetry $A_{1}^{n}$, the structure function ratio $g_{1}^{n}/F_{1}^{n}$, and the quark ratios $(Δu + Δ\bar{u})/(u + \bar{u})$ and $(Δd + Δ\bar{d})/(d + \bar{d})$. These results were found to be consistent with DIS world data and with the prediction of the constituent quark model but at odds with those of perturbative QCD at large $x$.

nucl-ex↗

A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab

A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maximum achieved green power at 5 W IR pump power is 1.74 W with a total conversion efficiency of 34.8\%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7~kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7\%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0\% precision in polarization measurements of an electron beam with energy and current of 1.0~GeV and 50~$μ$A.

physics.ins-det↗

Measurement of Parity-Violating Asymmetry in Electron-Deuteron Inelastic Scattering

The parity-violating asymmetries between a longitudinally-polarized electron beam and an unpolarized deuterium target have been measured recently. The measurement covered two kinematic points in the deep inelastic scattering region and five in the nucleon resonance region. We provide here details of the experimental setup, data analysis, and results on all asymmetry measurements including parity-violating electron asymmetries and those of inclusive pion production and beam-normal asymmetries. The parity-violating deep-inelastic asymmetries were used to extract the electron-quark weak effective couplings, and the resonance asymmetries provided the first evidence for quark-hadron duality in electroweak observables. These electron asymmetries and their interpretation were published earlier, but are presented here in more detail.

nucl-ex↗

A Precision Measurement of the Neutron Twist-3 Matrix Element $d_2^n$: Probing Color Forces

Double-spin asymmetries and absolute cross sections were measured at large Bjorken $x$ (0.25 $ \le x \le $ 0.90), in both the deep-inelastic and resonance regions, by scattering longitudinally polarized electrons at beam energies of 4.7 and 5.9 GeV from a transversely and longitudinally polarized $^3$He target. In this dedicated experiment, the spin structure function $g_2$ on $^3$He was determined with precision at large $x$, and the neutron twist-three matrix element $d_2^n$ was measured at $\left< Q^2\right>$ of 3.21 and 4.32 GeV$^2$/$c^2$, with an absolute precision of about $10^{-5}$. Our results are found to be in agreement with lattice QCD calculations and resolve the disagreement found with previous data at $\left< Q^2\right> =$ 5 GeV$^2$/$c^2$. Combining $d_2^n$ and a newly extracted twist-four matrix element, $f_2^n$, the average neutron color electric and magnetic forces were extracted and found to be of opposite sign and about 30 MeV/fm in magnitude.

nucl-ex↗

Weak charge form factor and radius of 208Pb through parity violation in electron scattering

We use distorted wave electron scattering calculations to extract the weak charge form factor F_W(q), the weak charge radius R_W, and the point neutron radius R_n, of 208Pb from the PREX parity violating asymmetry measurement. The form factor is the Fourier transform of the weak charge density at the average momentum transfer q=0.475 fm$^{-1}$. We find F_W(q) =0.204 \pm 0.028 (exp) \pm 0.001 (model). We use the Helm model to infer the weak radius from F_W(q). We find R_W= 5.826 \pm 0.181 (exp) \pm 0.027 (model) fm. Here the exp error includes PREX statistical and systematic errors, while the model error describes the uncertainty in R_W from uncertainties in the surface thickness σof the weak charge density. The weak radius is larger than the charge radius, implying a "weak charge skin" where the surface region is relatively enriched in weak charges compared to (electromagnetic) charges. We extract the point neutron radius R_n=5.751 \pm 0.175 (exp) \pm 0.026 (model) \pm 0.005 (strange) fm$, from R_W. Here there is only a very small error (strange) from possible strange quark contributions. We find R_n to be slightly smaller than R_W because of the nucleon's size. Finally, we find a neutron skin thickness of R_n-R_p=0.302\pm 0.175 (exp) \pm 0.026 (model) \pm 0.005 (strange) fm, where R_p is the point proton radius.

nucl-ex↗

Dark Sectors and New, Light, Weakly-Coupled Particles

Dark sectors, consisting of new, light, weakly-coupled particles that do not interact with the known strong, weak, or electromagnetic forces, are a particularly compelling possibility for new physics. Nature may contain numerous dark sectors, each with their own beautiful structure, distinct particles, and forces. This review summarizes the physics motivation for dark sectors and the exciting opportunities for experimental exploration. It is the summary of the Intensity Frontier subgroup "New, Light, Weakly-coupled Particles" of the Community Summer Study 2013 (Snowmass). We discuss axions, which solve the strong CP problem and are an excellent dark matter candidate, and their generalization to axion-like particles. We also review dark photons and other dark-sector particles, including sub-GeV dark matter, which are theoretically natural, provide for dark matter candidates or new dark matter interactions, and could resolve outstanding puzzles in particle and astro-particle physics. In many cases, the exploration of dark sectors can proceed with existing facilities and comparatively modest experiments. A rich, diverse, and low-cost experimental program has been identified that has the potential for one or more game-changing discoveries. These physics opportunities should be vigorously pursued in the US and elsewhere.

hep-ph↗

Measurement of the Parity-Violating Asymmetry in Electron-Deuteron Scattering in the Nucleon Resonance Region

We report on parity-violating asymmetries in the nucleon resonance region measured using $5 - 6$ GeV longitudinally polarized electrons scattering off an unpolarized deuterium target. These results are the first parity-violating asymmetry data in the resonance region beyond the $Δ(1232)$, and provide a verification of quark-hadron duality in the nucleon electroweak $γZ$ interference structure functions at the (10-15)% level. The results are of particular interest to models relevant for calculating the $γZ$ box-diagram corrections to elastic parity-violating electron scattering measurements.

nucl-ex↗

Comparison of Modeled and Measured Performance of a GSO Crystal as Gamma Detector

We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.

physics.ins-det↗

Hall A Annual Report 2012

Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.

physics.ins-det↗

New Measurements of the Transverse Beam Asymmetry for Elastic Electron Scattering from Selected Nuclei

We have measured the beam-normal single-spin asymmetry $A_n$ in the elastic scattering of 1-3 GeV transversely polarized electrons from $^1$H and for the first time from $^4$He, $^{12}$C, and $^{208}$Pb. For $^1$H, $^4$He and $^{12}$C, the measurements are in agreement with calculations that relate $A_n$ to the imaginary part of the two-photon exchange amplitude including inelastic intermediate states. Surprisingly, the $^{208}$Pb result is significantly smaller than the corresponding prediction using the same formalism. These results suggest that a systematic set of new $A_n$ measurements might emerge as a new and sensitive probe of the structure of heavy nuclei.

nucl-ex↗

Measurement of the Neutron Radius of 208Pb Through Parity-Violation in Electron Scattering

We report the first measurement of the parity-violating asymmetry A_PV in the elastic scattering of polarized electrons from 208Pb. A_PV is sensitive to the radius of the neutron distribution (Rn). The result A_PV = 0.656 \pm 0.060 (stat) \pm 0.014 (syst) ppm corresponds to a difference between the radii of the neutron and proton distributions Rn - Rp = 0.33 +0.16 -0.18 fm and provides the first electroweak observation of the neutron skin which is expected in a heavy, neutron-rich nucleus.

nucl-ex↗

An LED pulser for measuring photomultiplier linearity

A light-emitting diode (LED) pulser for testing the low-rate response of a photomultiplier tube (PMT) to scintillator-like pulses has been designed, developed, and implemented. This pulser is intended to simulate 80 ns full width at half maximum photon pulses over the dynamic range of the PMT, in order to precisely determine PMT linearity. This particular design has the advantage that, unlike many LED test rigs, it does not require the use of multiple calibrated LEDs, making it insensitive to LED gain drifts. Instead, a finite-difference measurement is made using two LEDs which need not be calibrated with respect to one another. These measurements give a better than 1% mapping of the response function, allowing for the testing and development of particularly linear PMT bases.

physics.ins-det↗

Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

physics.ins-det↗

New Precision Limit on the Strange Vector Form Factors of the Proton

The parity-violating cross-section asymmetry in the elastic scattering of polarized electrons from unpolarized protons has been measured at a four-momentum transfer squared Q2 = 0.624 GeV and beam energy E =3.48 GeV to be A_PV = -23.80 +/- 0.78 (stat) +/- 0.36 (syst) parts per million. This result is consistent with zero contribution of strange quarks to the combination of electric and magnetic form factors G_E^s + 0.517 G_M^s = 0.003 +/- 0.010 (stat) +/- 0.004 (syst) +/- 0.009 (ff), where the third error is due to the limits of precision on the electromagnetic form factors and radiative corrections. With this measurement, the world data on strange contributions to nucleon form factors are seen to be consistent with zero and not more than a few percent of the proton form factors.

nucl-ex↗