SearcharxivSearch

arXiv subjects

G. Bergamin

Publications and source records attributed to G. Bergamin.

3 recordsLinked to original sources

Beam-test evaluation of pre-production Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment as part of the Phase-II upgrade for the High Luminosity-Large Hadron Collider (HL-LHC). It will mitigate pile-up effects in the forward region, and measure per bunch luminosity. The design of HGTD is based on Low Gain Avalanche Detector (LGAD) sensors. This paper presents the results of beam-test campaigns conducted at CERN and DESY in 2023 and 2024 on single LGADs from HGTD pre-production test structures, before and after neutron irradiation up to fluences of $2.5 \times 10^{15}~\mathrm{n_{eq}/cm^2}$. The tested LGADs can meet HGTD requirements in terms of charge collection, time resolution, and hit efficiency, even under HL-LHC end-of-life conditions, supporting their deployment in the final detector.

physics.ins-det

Challenges and strategies in verification of FastRICH ASIC for the LHCb RICH detector

The FastRICH ASIC provides high-precision, triggerless readout for the LS3 Enhancements and Upgrades II of the LHCb RICH detector. The demands of continuous data acquisition and varying hit rates across the detector impose unique challenges on the ASIC's design and verification. This work presents the verification strategy for FastRICH, focusing on functional correctness, timing performance, and operational robustness. The methodology includes simulations across occupancy scenarios, validation of timing precision, and stress testing under pile-up and high-rate conditions. Results demonstrate that FastRICH meets its performance requirements over the full range of expected occupancies. Key design and verification challenges specific to triggerless, fast-timing ASICs are discussed, along with lessons learned for future developments.

physics.ins-det

Functional Verification for Endcap Concentrator ASICs in the High-Granularity Calorimeter Upgrade of CMS

The High-Granularity Calorimeter (HGCAL) will replace the current CMS Endcap Calorimeter during Long-Shutdown 3. The Endcap Concentrator (ECON) ASICs represent key elements in the readout chain, processing trigger (ECON-T) and data (ECON-D) streams from the HGCROC to the lpGBT. The ECONs will operate in a radiation environment with a High-Energy Hadron (${E\geq20MeV}$) flux up to $2\cdot10^{7} cm^{-2}s^{-1}$. This contribution describes the Universal Verification Methodology (UVM)-based functional verification of the ECON ASICs focusing on the re-use of existing components to manage the complexity of the verification environment.