SearcharxivSearch

arXiv subjects

G. Boca

Publications and source records attributed to G. Boca.

At least 19 recordsLinked to original sources

ePIC Early Science Report

This Early Science Report from the ePIC Collaboration outlines the compelling physics program achievable during the first years of operation of the Electron-Ion Collider (EIC), prior to the establishment of the full design luminosity and energy range. The analyses are based on realistic early-running beam configurations and detailed Geant4 ePIC detector simulations, hit digitization and data reconstruction. The projected studies from the physics working groups of ePIC span inclusive, semi-inclusive, exclusive, diffractive and tagging, as well as jet and heavy flavor measurements in both electron-proton and electron-ion collisions. Even before the collider reaches its full design performance, these measurements will constrain parton distribution functions in nucleons and nuclei, access transverse-momentum-dependent and spin-dependent observables, probe gluon dynamics in nuclei, and initiate a program of imaging of quarks and gluons. Each measurement is directly connected to the core science pillars of the EIC, identified in the 2018 report by the National Academy of Sciences: understanding the origin of the nucleon mass, unraveling the spin structure of the nucleon, and exploring the emergent properties of dense gluonic matter. The results presented here provide examples that demonstrate that the early years of EIC running with ePIC will deliver novel world-leading insights into Quantum Chromodynamics. In addition, the early science program will establish measurement and analysis methodologies that will pave the way to the subsequent full EIC physics program.

nucl-ex

Sensor operating point calibration and monitoring of the ALICE Inner Tracking System during LHC Run 3

The new Inner Tracking System (ITS2) of the ALICE experiment began operation in 2021 with the start of LHC Run 3. Compared to its predecessor, ITS2 offers substantial improvements in pointing resolution, tracking efficiency at low transverse momenta, and readout-rate capabilities. The detector employs silicon Monolithic Active Pixel Sensors (MAPS) featuring a pixel size of 26.88$\times$29.24 $\mu$m$^2$ and an intrinsic spatial resolution of approximately 5 $\mu$m. With a remarkably low material budget of 0.36% of radiation length ($X_{0}$) per layer in the three innermost layers and a total sensitive area of about 10 m$^2$, the ITS2 constitutes the largest-scale application of MAPS technology in a high-energy physics experiment and the first of its kind operated at the LHC. For stable data taking, it is crucial to calibrate different parameters of the detector, such as in-pixel charge thresholds and the masking of noisy pixels. The calibration of 24120 monolithic sensors, comprising a total of 12.6$\times$10$^{9}$ pixels, represents a major operational challenge. This paper presents the methods developed for the calibration of the ITS2 and outlines the strategies for monitoring and dynamically adjusting the detector's key performance parameters over time.

physics.ins-det

New limit on the \mu+->e+\gamma decay with the MEG II experiment

This letter reports the result of the search for the decay \mu+->e+\gamma undertaken at the Paul Scherrer Institut in Switzerland with the MEG II experiment using the data collected in the 2021- 2022 physics runs. The sensitivity of this search is 2.2x10-13, a factor of 2.4 better than that of the full MEG dataset and obtained in a data taking period of about one fourth that of MEG, thanks to the superior performances of the new detector. The result is consistent with the expected background, yielding an upper limit on the branching ratio of B(\mu+->e+\gamma)<1.5 x 10-13 (90 % C.L.). Additional improvements are expected with the data collected during the years 2023-2024. The data-taking will continue in the coming years.

hep-ex

Search for the X17 particle in $^{7}\mathrm{Li}(\mathrm{p},\mathrm{e}^+ \mathrm{e}^{-}) ^{8}\mathrm{Be}$ processes with the MEG II detector

The observation of a resonance structure in the opening angle of the electron-positron pairs in the $^{7}$Li(p,\ee) $^{8}$Be reaction was claimed and interpreted as the production and subsequent decay of a hypothetical particle (X17). Similar excesses, consistent with this particle, were later observed in processes involving $^{4}$He and $^{12}$C nuclei with the same experimental technique. The MEG II apparatus at PSI, designed to search for the $\mu^+ \rightarrow \mathrm{e}^+ \gamma$ decay, can be exploited to investigate the existence of this particle and study its nature. Protons from a Cockroft-Walton accelerator, with an energy up to 1.1 MeV, were delivered on a dedicated Li-based target. The $\gamma$ and the e$^{+}$e$^{-}$ pair emerging from the $^8\mathrm{Be}^*$ transitions were studied with calorimeters and a spectrometer, featuring a broader angular acceptance than previous experiments. We present in this paper the analysis of a four-week data-taking in 2023 with a beam energy of 1080 keV, resulting in the excitation of two different resonances with Q-value \SI{17.6}{\mega\electronvolt} and \SI{18.1}{\mega\electronvolt}. No significant signal was found, and limits at \SI{90}{\percent} C.L. on the branching ratios (relative to the $\gamma$ emission) of the two resonances to X17 were set, $R_{17.6} < 1.8 \times 10^{-6} $ and $R_{18.1} < 1.2 \times 10^{-5} $.

nucl-ex

A search for $\mu^+\to e^+\gamma$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $\mu^+\to e^+\gamma$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($\mu^+\to e^+\gamma$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($\mu^+\to e^+\gamma$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

hep-ex

Performances of a new generation tracking detector: the MEG II cylindrical drfit chamber

The cylindrical drift chamber is the most innovative part of the MEG~II detector, the upgraded version of the MEG experiment. The MEG~II chamber differs from the MEG one because it is a single volume cylindrical structure, instead of a segmented one, chosen to improve its resolutions and efficiency in detecting low energy positrons from muon decays at rest. In this paper, we show the characteristics and performances of this fundamental part of the MEG~II apparatus and we discuss the impact of its higher resolution and efficiency on the sensitivity of the MEG~II experiment. Because of its innovative structure and high quality resolution and efficiency the MEG~II cylindrical drift chamber will be a cornerstone in the development of an ideal tracking detector for future positron-electron collider machines.

physics.ins-det

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

physics.ins-det

First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors

A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$\mu$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$\mu$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance. In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.

physics.ins-det

Timing resolution of a plastic scintillator counter read out by radiation damaged SiPMs connected in series

This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $\Phi_\mathrm{e^-}\approx 3 \times 10^{12}~\mathrm{cm}^{-2}$. The timing resolution of the counter gradually deteriorated by the increase in dark current. The dark current and the deterioration were reduced when the counter was cooled from 30$^\circ$C to 10$^\circ$C. Secondly, 33 SiPMs were irradiated with reactor neutrons. The characteristics of counters read out by series-connected SiPMs with non-uniform damage levels, were investigated. The signal pulse height, the time response, and the timing resolution depend on the hit position in the counter, when SiPMs' irradiation is not uniform.

physics.ins-det

Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment

We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $\mu^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to \gamma\gamma$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20--40 MeV/c$^2$, down to $\mathcal{O}(10^{-11})$ at 90\% confidence level.

hep-ex

The laser-based time calibration system for the MEG II pixelated Timing Counter

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator counter via several optical components so that we can directly measure the time offset of each counter relative to the laser-emitted time. We carefully tested all the components and procedures prior to the actual operation. The laser system was installed into the pTC and thoroughly tested under the real experimental condition. The system showed good stability and being sensitive to any change of timing larger than ~10 ps. Moreover, it showed an uncertainty of 48 ps in the determination of the time offsets, which meets our requirements. The new method provides an example of the implementation of a precise timing alignment for the new type of detectors enabled by the advance of SiPM technology.

physics.ins-det

A Laser-based Time Calibration System for the MEG II Timing Counter

We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this study, we present the calibration system which can directly measure the time offset of each counter relative to the laser-synchronized pulse. We thoroughly tested all the optical components and the uncertainty of this method is estimated to be 24 ps. In 2017, we installed the full system into the MEG II environment and performed a commissioning run. This method shows excellent stability and consistency with another method. The proposed system provides a precise timing alignment for SiPM-based timing detectors. It also has potential in areas such as TOF-PET.

physics.ins-det

Results from Pilot Run for MEG II Positron Timing Counter

The MEG II experiment at Paul Scherrer Institut in Switzerland will search for the lepton flavour violating muon decay, $\mu^+\to e^+\gamma$, with a sensitivity of $4\times10^{-14}$ improving the existing limit of an order of magnitude. In 2016, we finished the construction of the MEG II Timing Counter, the subdetector dedicated to the measurement of the positron emission time. The first one-fourth of it was installed in the experimental area and we performed a pilot run with the MEG~II beam of $7\times10^{7}\mu^+/$s. The timing resolution reached the design value improving by a factor of two compared to MEG.

physics.ins-det

The design of the MEG II experiment

The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.

physics.ins-det

Muon polarization in the MEG experiment: predictions and measurements

The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.

hep-ex

Measurement of the radiative decay of polarized muons in the MEG experiment

We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.

hep-ex

New constraint on the existence of the mu+-> e+ gamma decay

The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.

hep-ex

The MEG detector for $μ+\to e+γ$ decay search

The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.

physics.ins-det