RF pulse amplifier for CVD-diamond particle detectors

This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from {\alpha} particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stamping, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier offers the possibility of high voltage biasing, a characteristic essential for driving diamond detectors. Finally the greatest asset of this study is certainly the minimization of the power consumption, which allows us to consider designs with multiple amplifiers, in limited space, for striped diamond detectors.

physics.ins-det

The STEREO Experiment

The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.

physics.ins-det

The NIKA2 instrument at 30-m IRAM telescope: performance and results

The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy, such as Intra Cluster Medium from intermediate to distant clusters and so for the follow-up of Planck satellite detected clusters, high redshift sources and quasars, early stages of star formation and nearby galaxies emission. We present an overview of the instrument performance as it has been evaluated at the end of the commissioning phase.

astro-ph.IM

First detection of tracks of radon progeny recoils by MIMAC

The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the Modane underground laboratory. In this paper, we report the first ionization energy and 3D track observations of nuclear recoils produced by the radon progeny. This measurement shows the capability of the MIMAC detector and opens the possibility to explore the low energy recoil directionality signature.

astro-ph.IM

NIKEL_AMC: Readout electronics for the NIKA2 experiment

The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.

astro-ph.IM

Readout technologies for directional WIMP Dark Matter detection

The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.

physics.ins-det

MIMAC low energy electron-recoil discrimination measured with fast neutrons

MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^5$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a 105 electron rejection power is reached with a $86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range and $94.67\pm0.19$\% considering a 5~keV lower threshold.

astro-ph.IM

Production of highly-polarized positrons using polarized electrons at MeV energies

The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an initial electron beam momentum of 8.19~MeV/$c$, limited only by the electron beam polarization. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community.

physics.acc-ph

Trigger and readout electronics for the STEREO experiment

The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomultiplier signals continuously digitized at 250 MSPS. Additionally, for detector performance monitoring, the electronics allow on-line calibration by driving LED synchronously with the data acquisition. This paper describes the electronics requirements, architecture and the performances achieved.

physics.ins-det

In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while keeping almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.

astro-ph.IM

Measurement of a 127 keV Neutron Field with a micro-TPC Spectrometer

In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector principle. The instrument is presented with the associated method to measure the neutron energy. This article emphasizes the proton energy calibration procedure and energy measurements of a neutron field produced at 127 keV with the IRSN facility AMANDE.

physics.ins-det

Measurement of the electron drift velocity for directional dark matter detectors

Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the electron drift velocity while keeping almost the same Fluorine content of the gas mixture.

astro-ph.IM

MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.

physics.ins-det

Development of a microtpc detector as a standard instrument for low energy neutron field characterization

In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track reconstruction of recoiling nuclei down to a few keV, which can be achieved with a low pressure gaseous detector using a micro-pattern gaseous detector. A gas mixture, mainly isobutane, is used as a n-p converter to detect neutrons into the detection volume. Then electrons, coming from the ionization of the gas by the proton recoil, are collected by the pixelised anode (2D projection). A self-triggered electronics is able to perform the anode readout at a 50 MHz frequency in order to give the third dimension of the track. Then the scattering angle is deduced from this track using algorithms. The charge collection leads to the proton energy, taking into account the ionization quenching factor. This article emphasizes the neutron energy measurements of a monoenergetic neutron field produced at 127 keV. The measurements are compared to Monte Carlo simulations using realistic neutron fields and simulations of the detector response. The discrepancy between experiments and simulations is 5 keV mainly due to the calibration uncertainties of 10%.

physics.ins-det

Dark Matter directional detection with MIMAC

Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters. The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is being developed. In June 2012, a bi-chamber prototype was installed at the LSM (Laboratoire Souterrain de Modane). A preliminary analysis of the first four months data taking allowed, for the first time, the observation of recoils from the $\mathrm{^{222}Rn}$ progeny.

astro-ph.IM

MIMAC: A micro-tpc matrix for dark matter directional detection

The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.

physics.ins-det

A μ-TPC detector for the characterization of low energy neutron fields

The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up to 1 MeV. In this work we present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of these neutron fields.

physics.ins-det

Development and validation of a 64 channel front end ASIC for 3D directional detection for MIMAC

A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50 MHz, can be transferred at 400MHz by eight LVDS serial links. Eight ASIC were validated on a 2x256 strips of pixels prototype.

astro-ph.IM