SearcharxivSearch

arXiv subjects

G. Cagnoli

Publications and source records attributed to G. Cagnoli.

At least 19 recordsLinked to original sources

Advanced Virgo Plus for O5 -- Design Report Overview

This document presents an overview of the design, implementation, and expected performance of the Advanced Virgo Plus (AdV+) upgrades in view of the O5 observing run. Following the experience gained during the O4 commissioning and operations, the Virgo Collaboration has revised the upgrade strategy to address limitations associated with marginally stable recycling cavities. The O5 upgrade program combines elements from the original AdV+ Phase II project with new design solutions, including the implementation of stable recycling cavities, a major modification to the central interferometer layout, and a comprehensive renewal of critical subsystems. The planned upgrades are organized in two steps, targeting progressive improvements in operational stability, noise reduction, and detector sensitivity. Key developments include new vacuum infrastructures, suspensions, mirrors, optical configurations, quantum noise reduction systems, and high-power laser technologies. The resulting configuration is expected to significantly enhance the interferometer performance, enabling a substantial increase in astrophysical reach and scientific return during O5.

astro-ph.IM

Development of ion-beam sputtered silicon nitride thin films for low-noise mirror coatings of gravitational-wave detectors

Brownian thermal noise of thin-film coatings is a fundamental limit for high-precision experiments based on optical resonators such as gravitational-wave interferometers. Here we present the results of a research activity aiming to develop lower-noise ion-beam sputtered silicon nitride thin films compliant with the very stringent requirements on optical loss of gravitational-wave interferometers. In order to test the hypothesis of a correlation between the synthesis conditions of the films and their elemental composition and optical and mechanical properties, we varied the voltage, current intensity and composition of the sputtering ion beam, and we performed a broad campaign of characterizations. While the refractive index was found to monotonically depend on the beam voltage and linearly vary with the N/Si ratio, the optical absorption appeared to be strongly sensitive to other factors, as yet unidentified. However, by systematically varying the deposition parameters, an optimal working point was found. Thus we show that the loss angle and extinction coefficient of our thin films can be as low as $(1.0 \pm 0.1) \times 10^{-4}$ rad at $\sim$2.8 kHz and $(6.4 \pm 0.2) \times 10^{-6}$ at 1064 nm, respectively, after thermal treatment at 900 $^{\circ}$C. To the best of our knowledge, such loss angle value is the lowest ever measured on this class of thin films. We then used our silicon nitride thin films to design and produce a multi-material mirror coating showing a thermal noise amplitude of $(10.3 \pm 0.2) \times 10^{-18}$ m Hz$^{-1/2}$ at 100 Hz, which is 25\% lower than in current mirror coatings of the Advanced LIGO and Advanced Virgo interferometers, and an optical absorption as low as $(1.6 \pm 0.5)$ parts per million at 1064 nm.

physics.ins-det

Determination of compressive stress in thin films using micro-machined buckled membranes

In this work, optical profilometry and finite-element simulations are applied on buckled micro-machined membranes for the stress analysis of ion-beam-sputtered $\mathrm{Ta_{2}O_{5}}$ and $\mathrm{SiO_{2}}$ thin films. Layers with different thicknesses are grown on silicon substrates, then several membranes with different geometries are manufactured with standard micro-system technologies; due to a high level of the films' compressive stress, buckled membranes are obtained. Thermally-grown silica membranes are also produced, for comparison. The residual stress values are determined by comparing the measured and simulated deflections of the membranes. The average stress state of the $\mathrm{Ta_{2}O_{5}}$ thin films is found to be $-209$ MPa. The $\mathrm{SiO_{2}}$ thin films are in a higher compressive stress state whose average value is $-576$ MPa. The average stress in thermal $\mathrm{SiO_{2}}$ thin layers grown at 1130 $^{\circ}$C is found equal to $-321$ MPa, in good agreement with the literature.

physics.app-ph

Virgo Detector Characterization and Data Quality: results from the O3 run

The Advanced Virgo detector has contributed with its data to the rapid growth of the number of detected gravitational-wave (GW) signals in the past few years, alongside the two Advanced LIGO instruments. First during the last month of the Observation Run 2 (O2) in August 2017 (with, most notably, the compact binary mergers GW170814 and GW170817), and then during the full Observation Run 3 (O3): an 11-months data taking period, between April 2019 and March 2020, that led to the addition of about 80 events to the catalog of transient GW sources maintained by LIGO, Virgo and now KAGRA. These discoveries and the manifold exploitation of the detected waveforms require an accurate characterization of the quality of the data, such as continuous study and monitoring of the detector noise sources. These activities, collectively named {\em detector characterization and data quality} or {\em DetChar}, span the whole workflow of the Virgo data, from the instrument front-end hardware to the final analyses. They are described in details in the following article, with a focus on the results achieved by the Virgo DetChar group during the O3 run. Concurrently, a companion article describes the tools that have been used by the Virgo DetChar group to perform this work.

gr-qc

Virgo Detector Characterization and Data Quality: tools

Detector characterization and data quality studies -- collectively referred to as {\em DetChar} activities in this article -- are paramount to the scientific exploitation of the joint dataset collected by the LIGO-Virgo-KAGRA global network of ground-based gravitational-wave (GW) detectors. They take place during each phase of the operation of the instruments (upgrade, tuning and optimization, data taking), are required at all steps of the dataflow (from data acquisition to the final list of GW events) and operate at various latencies (from near real-time to vet the public alerts to offline analyses). This work requires a wide set of tools which have been developed over the years to fulfill the requirements of the various DetChar studies: data access and bookkeeping; global monitoring of the instruments and of the different steps of the data processing; studies of the global properties of the noise at the detector outputs; identification and follow-up of noise peculiar features (whether they be transient or continuously present in the data); quick processing of the public alerts. The present article reviews all the tools used by the Virgo DetChar group during the third LIGO-Virgo Observation Run (O3, from April 2019 to March 2020), mainly to analyse the Virgo data acquired at EGO. Concurrently, a companion article focuses on the results achieved by the DetChar group during the O3 run using these tools.

gr-qc

The Virgo O3 run and the impact of the environment

Sources of geophysical noise (such as wind, sea waves and earthquakes) or of anthropogenic noise impact ground-based gravitational-wave interferometric detectors, causing transient sensitivity worsening and gaps in data taking. During the one year-long third Observing Run (O3: from April 01, 2019 to March 27, 2020), the Virgo Collaboration collected a statistically significant dataset, used in this article to study the response of the detector to a variety of environmental conditions. We correlated environmental parameters to global detector performance, such as observation range, duty cycle and control losses. Where possible, we identified weaknesses in the detector that will be used to elaborate strategies in order to improve Virgo robustness against external disturbances for the next data taking period, O4, currently planned to start at the end of 2022. The lessons learned could also provide useful insights for the design of the next generation of ground-based interferometers.

gr-qc

Virgo Detector Characterization and Data Quality during the O3 run

The Advanced Virgo detector has contributed with its data to the rapid growth of the number of detected gravitational-wave signals in the past few years, alongside the two LIGO instruments. First, during the last month of the Observation Run 2 (O2) in August 2017 (with, most notably, the compact binary mergers GW170814 and GW170817) and then during the full Observation Run 3 (O3): an 11 months data taking period, between April 2019 and March 2020, that led to the addition of about 80 events to the catalog of transient gravitational-wave sources maintained by LIGO, Virgo and KAGRA. These discoveries and the manifold exploitation of the detected waveforms require an accurate characterization of the quality of the data, such as continuous study and monitoring of the detector noise. These activities, collectively named {\em detector characterization} or {\em DetChar}, span the whole workflow of the Virgo data, from the instrument front-end to the final analysis. They are described in details in the following article, with a focus on the associated tools, the results achieved by the Virgo DetChar group during the O3 run and the main prospects for future data-taking periods with an improved detector.

gr-qc

Characterization of ion-beam-sputtered AlF$_3$ thin films for gravitational-wave interferometers

Thermal noise in amorphous coatings is a limitation for a wide range of precision experiments such as gravitational-wave detectors (GWDs). Mirrors for GWDs are composed of multiple thin layers of dielectric materials deposited on a substrate: the stack is made of layers with a high refractive index interleaved with layers of a low refractive index. The goal is to obtain high reflectivity and low thermal noise. In this paper we report on the optical and mechanical properties of ion-beam-sputtered aluminium fluoride (AlF$_3$) thin films which have one of the lowest refractive index among the known coating materials and we discuss their application in current and future GWDs.

physics.ins-det

Optical and mechanical properties of ion-beam-sputtered MgF$_2$ thin films for gravitational-wave interferometers

Brownian thermal noise associated with highly reflective coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Research is currently ongoing to find coatings with low thermal noise that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical properties of ion-beam-sputtered magnesium fluoride thin films, and we discuss the application of such coatings in current and future gravitational-wave detectors.

physics.ins-det

Calibration of Advanced Virgo and reconstruction of detector strain h(t) during the Observing Run O3

The three Advanced Virgo and LIGO gravitational wave detectors participated to the third observing run (O3) between 1 April 2019 15:00 UTC and 27 March 2020 17:00 UTC,leading to several gravitational wave detections per month. This paper describes the Advanced Virgo detector calibration and the reconstruction of the detector strain $h(t)$ during O3, as well as the estimation of the associated uncertainties. For the first time, the photon calibration technique as been used as reference for Virgo calibration, which allowed to cross-calibrate the strain amplitude of the Virgo and LIGO detectors. The previous reference, so-called free swinging Michelson technique, has still been used but as an independent cross-check. $h(t)$ reconstruction and noise subtraction were processed online, with good enough quality to prevent the need for offline reprocessing, except for the two last weeks of September 2019. The uncertainties for the reconstructed $h(t)$ strain, estimated in this paper in a 20-2000~Hz frequency band, are frequency independent: 5% in amplitude, 35 mrad in phase and 10 $μ$s in timing, with the exception of larger uncertainties around 50 Hz.

gr-qc

Exploration of co-sputtered Ta$_2$O$_5$-ZrO$_2$ thin films for gravitational-wave detectors

We report on the development and extensive characterization of co-sputtered tantala-zirconia thin films, with the goal to decrease coating Brownian noise in present and future gravitational-wave detectors. We tested a variety of sputtering processes of different energies and deposition rates, and we considered the effect of different values of cation ratio $η=$ Zr/(Zr+Ta) and of post-deposition heat treatment temperature $T_a$ on the optical and mechanical properties of the films. Co-sputtered zirconia proved to be an efficient way to frustrate crystallization in tantala thin films, allowing for a substantial increase of the maximum annealing temperature and hence for a decrease of coating mechanical loss. The lowest average coating loss was observed for an ion-beam sputtered sample with $η= 0.485 \pm 0.004$ annealed at 800 $^{\circ}$C, yielding $\overlineφ = 1.8 \times 10^{-4}$. All coating samples showed cracks after annealing. Although in principle our measurements are sensitive to such defects, we found no evidence that our results were affected. The issue could be solved, at least for ion-beam sputtered coatings, by decreasing heating and cooling rates down to 7 $^{\circ}$C/h. While we observed as little optical absorption as in the coatings of current gravitational-wave interferometers (0.5 parts per million), further development will be needed to decrease light scattering and avoid the formation of defects upon annealing.

physics.ins-det

Optical and mechanical properties of ion-beam-sputtered Nb$_2$O$_5$ and TiO$_2$-Nb$_2$O$_5$ thin films for gravitational-wave interferometers

Brownian thermal noise associated with highly-reflective mirror coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Recently, there has been a worldwide effort to find mirror coatings with improved thermal noise properties that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical properties of ion-beam-sputtered niobia and titania-niobia thin films, and we discuss application of such coatings in current and future gravitational-wave detectors. We also report an updated direct coating thermal noise measurement of the HR coatings used in Advanced LIGO and Advanced Virgo.

physics.ins-det

A standard siren measurement of the Hubble constant from GW170817 without the electromagnetic counterpart

We perform a statistical standard siren analysis of GW170817. Our analysis does not utilize knowledge of NGC 4993 as the unique host galaxy of the optical counterpart to GW170817. Instead, we consider each galaxy within the GW170817 localization region as a potential host; combining the redshift from each galaxy with the distance estimate from GW170817 provides an estimate of the Hubble constant, $H_0$. We then combine the $H_0$ values from all the galaxies to provide a final measurement of $H_0$. We explore the dependence of our results on the thresholds by which galaxies are included in our sample, as well as the impact of weighting the galaxies by stellar mass and star-formation rate. Considering all galaxies brighter than $0.01 L^\star_B$ as equally likely to host a BNS merger, we find $H_0= 76^{+48}_{-23}$ km s$^{-1}$ Mpc$^{-1}$ (maximum a posteriori and 68.3% highest density posterior interval; assuming a flat $H_0$ prior in the range $\left[ 10, 220 \right]$ km s$^{-1}$ Mpc$^{-1}$). Restricting only to galaxies brighter than $0.626 L^\star_B$ tightens the measurement to $H_0= 77^{+37}_{-18}$ km s$^{-1}$ Mpc$^{-1}$. We show that weighting the host galaxies by stellar mass or star-formation rate provides entirely consistent results with potentially tighter constraints. While these statistical estimates are inferior to the value from the counterpart standard siren measurement utilizing NGC 4993 as the unique host, $H_0=76^{+19}_{-13}$ km s$^{-1}$ Mpc$^{-1}$ (determined from the same publicly available data), our analysis is a proof-of-principle demonstration of the statistical approach first proposed by Bernard Schutz over 30 years ago.

astro-ph.CO

Calibration of Advanced Virgo and Reconstruction of the Gravitational Wave Signal h(t) during the Observing Run O2

In August 2017, Advanced Virgo joined Advanced LIGO for the end of the O2 run, leading to the first gravitational waves detections with the three-detector network. This paper describes the Advanced Virgo calibration and the gravitational wave strain h(t) reconstruction during O2. The methods are the same as the ones developed for the initial Virgo detector and have already been described in previous publications, this paper summarizes the differences and emphasis is put on estimating systematic uncertainties. Three versions of the h(t) signal have been computed for the Virgo O2 run, an online version and two post-run reprocessed versions with improved detector calibration and reconstruction algorithm. A photon calibrator has been used to establish the sign of h(t) and to make an independent partial cross-check of the systematic uncertainties. The uncertainties reached for the latest h(t) version are 5.1% in amplitude, 40 mrad in phase and 20 microseconds in timing.

gr-qc

2D photonic-crystal optomechanical nanoresonator

We present the optical optimization of an optomechanical device based on a suspended InP membrane patterned with a 2D near-wavelength grating (NWG) based on a 2D photonic-crystal geometry. We first identify by numerical simulation a set of geometrical parameters providing a reflectivity higher than 99.8 % over a 50-nm span. We then study the limitations induced by the finite value of the optical waist and lateral size of the NWG pattern using different numerical approaches. The NWG grating, pierced in a suspended InP 265 nm-thick membrane, is used to form a compact microcavity involving the suspended nano-membrane as end mirror. The resulting cavity has a waist size smaller than 10 $μ$m and a finesse in the 200 range. It is used to probe the Brownian motion of the mechanical modes of the nanomembrane.

cond-mat.mes-hall

Advanced Virgo: a 2nd generation interferometric gravitational wave detector

Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two Advanced LIGO detectors in the US and GEO HF in Germany, with the goal of contributing to the early detections of gravitational waves and to opening a new observation window on the universe. In this paper we describe the main features of the Advanced Virgo detector and outline the status of the construction.

gr-qc

Reconstruction of the gravitational wave signal $h(t)$ during the Virgo science runs and independent validation with a photon calibrator

The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$ from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the $h(t)$ signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed $h(t)$ signal and the associated uncertainties. The uncertainties of the $h(t)$ time series are estimated to be 8% in amplitude. The uncertainty of the phase of $h(t)$ is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 $μ$s at high frequency. A bias lower than $4\,\mathrm{μs}$ and depending on the sky direction of the GW is also present.

gr-qc

Characterization of the Virgo Seismic Environment

The Virgo gravitational wave detector is an interferometer (ITF) with 3km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several techniques adopted to isolate the interferometer from the environment, seismic noise remains an important issue for Virgo. Vibrations produced by the detector infrastructure (such as air conditioning units, water chillers/heaters, pumps) are found to affect Virgo's sensitivity, with the main coupling mechanisms being through beam jitter and scattered light processes. The Advanced Virgo (AdV) design seeks to reduce ITF couplings to environmental noise by having most vibration-sensitive components suspended and in-vacuum, as well as muffle and relocate loud machines. During the months of June and July 2010, a Guralp-3TD seismometer was stationed at various locations around the Virgo site hosting major infrastructure machines. Seismic data were examined using spectral and coherence analysis with seismic probes close to the detector. The primary aim of this study was to identify noisy machines which seismically affect the ITF environment and thus require mitigation attention. Analyzed machines are located at various distances from the experimental halls, ranging from 10m to 100m. An attempt is made to measure the attenuation of emitted noise at the ITF and correlate it to the distance from the source and to seismic attenuation models in soil.

gr-qc