Searcharxiv⌕ Search

arXiv subjects

G. Carosi

Publications and source records attributed to G. Carosi.

At least 37 records · Page 2Linked to original sources

Axion Dark Matter eXperiment: Run 1B Analysis Details

Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for Run 1B, motivating analysis choices informed by details specific to this run.

astro-ph.CO↗

Axion Dark Matter eXperiment: Detailed Design and Operations

Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.

astro-ph.IM↗

Avoided mode crossings in cylindrical microwave cavities

Axion haloscope detectors require high-$Q$ cavities with tunable TM$_{010}$ modes whose resonant electric field occupies as much of the full volume of the cavity as possible. An analytical study of the effects of longitudinal symmetry breaking within microwave cavities was conducted to better understand the mode structure. The study revealed longitudinal symmetry breaking of the cavities was the mechanism for avoided mode crossings (AMC) in cylindrical microwave cavities. The results showed the size of the gaps in the search frequency spectrum due to an AMC was roughly proportional to the magnitude of symmetry breaking for small perturbations.

physics.ins-det↗

Extended Search for the Invisible Axion with the Axion Dark Matter Experiment

This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.

hep-ex↗

Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter

The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.

hep-ex↗

Modulation Sensitive Search for Non-Virialized Dark-Matter Axions

Non-virialized dark-matter axions may be present in the Milky Way halo in the form of low-velocity-dispersion flows. The Axion Dark Matter eXperiment performed a search for the conversion of these axions into microwave photons using a resonant cavity immersed in a strong, static magnetic field. The spread of photon energy in these measurements was measured at spectral resolutions of the order of 1 Hz and below. If the energy variation were this small, the frequency modulation of any real axion signal due to the orbital and rotational motion of the Earth would become non-negligible. Conservative estimates of the expected signal modulation were made and used as a guide for the search procedure. The photon frequencies covered by this search are 812$-$852 and 858$-$892 MHz, which correspond to an axion mass of 3.36$-$3.52 and 3.55$-$3.69 μeV. No axion signal was found, and limits were placed on the maximum local density of non-virialized axions of these masses.

astro-ph.CO↗

A Search for Invisible Axion Dark Matter with the Axion Dark Matter Experiment

This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultra-low-noise SQUID amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.

hep-ex↗

Results from phase 1 of the HAYSTAC microwave cavity axion experiment

We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.

hep-ex↗

Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range

We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.

physics.ins-det↗

First results from a microwave cavity axion search at 24 micro-eV

We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.

astro-ph.CO↗

Cavity design for high-frequency axion dark matter detectors

In an effort to extend the usefulness of microwave cavity detectors to higher axion masses, above ~8 $μ$eV (~2 GHz), a numerical trade study of cavities was conducted to investigate the merit of using variable periodic post arrays and regulating vane designs for higher-frequency searches. The results show that both designs could be used to develop resonant cavities for high-mass axion searches. Multiple configurations of both methods obtained the scanning sensitivity equivalent to approximately 4 coherently coupled cavities with a single tuning rod.

physics.ins-det↗

Future Directions in the Microwave Cavity Search for Dark Matter Axions

The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrated sensitivity to plausible axion models, and upgrades in progress should achieve the sensitivity required for a definitive search, at least for low mass axions. However, a comprehensive strategy for scanning the entire mass range, from 1-1000 $μ$eV, will require significant technological advances to maintain the needed sensitivity at higher frequencies. Such advances could include sub-quantum-limited amplifiers based on squeezed vacuum states, bolometers, and/or superconducting microwave cavities. The Axion Dark Matter eXperiment at High Frequencies (ADMX-HF) represents both a pathfinder for first data in the 20-100 $μ$eV range ($\sim$5-25 GHz), and an innovation test-bed for these concepts.

physics.ins-det↗

Probing the axion-photon coupling: phenomenological and experimental perspectives. A snowmass white paper

We present a brief overview of the ongoing searches for the axion particle via its coupling to photons. Both the classical QCD axions and more recently proposed Axion-Like-Particles are considered. Astrophysical bounds on the axion-photon coupling come from considerations of stellar energy loss during Helium burning, in both low- and high-mass stars. Helioscopes look for back-conversion of solar axions into x-ray photons in strong laboratory magnetic fields. Finally, haloscopes aim to detect dark matter axions in our galactic halo. Both types of searches are expecting significant advances in the future, which will enable them to probe large, well-motivated parts of the parameter space below the stellar cooling bounds.

hep-ph↗

Analysis of single-photon and linear amplifier detectors for microwave cavity dark matter axion searches

We show that at higher frequencies, and thus higher axion masses, single-photon detectors become competitive and ultimately favored, when compared to quantum-limited linear amplifiers, as the detector technology in microwave cavity experimental searches for galactic halo dark matter axions. The cross-over point in this comparison is of order 10 GHz ($\sim 40\ μ$eV), not far above the frequencies of current searches.

physics.ins-det↗

Fundamental Physics at the Intensity Frontier

The Proceedings of the 2011 workshop on Fundamental Physics at the Intensity Frontier. Science opportunities at the intensity frontier are identified and described in the areas of heavy quarks, charged leptons, neutrinos, proton decay, new light weakly-coupled particles, and nucleons, nuclei, and atoms.

hep-ex↗

A search for non-virialized axionic dark matter

Cold dark matter in the Milky Way halo may have structure defined by flows with low velocity dispersion. The Axion Dark Matter eXperiment high resolution channel is especially sensitive to axions in such low velocity dispersion flows. Results from a combined power spectra analysis of the high resolution channel axion search are presented along with a discussion of the assumptions underlying such an analysis. We exclude KSVZ axion dark matter densities of ρ > 0.2 GeV/cm^3 and DFSZ densities of ρ > 1.4 GeV/cm^3 over a mass range of m_a = 3.3μeV to 3.69μeV for models having velocity dispersions of Δβ < 3x10^-6.

astro-ph.CO↗

Move of a large but delicate apparatus on a trailer with air-ride suspension

When valuable delicate goods are shipped by truck, attention must be paid to vibrations that may cause damage. We present a case study of moving an extremely delicate 6230-kg superconducting magnet, immersed in liquid nitrogen, from Livermore, CA to Seattle, WA showing the steps of fatigue analysis of the load, a test move, and acceleration monitoring of the final move to ensure a successful damage-free transport.

physics.ins-det↗

Design and performance of the ADMX SQUID-based microwave receiver

The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device (SQUID). We describe the ADMX receiver in detail as well as the analysis of narrow band microwave signals. We demonstrate the sustained use of a SQUID amplifier operating between 812 and 860 MHz with a noise temperature of 1 K. The receiver has a noise equivalent power of 1.1x10^-24 W/sqrt(Hz) in the band of operation for an integration time of 1.8x10^3 s.

physics.ins-det↗