SearcharxivSearch

arXiv subjects

G. Chardin

Publications and source records attributed to G. Chardin.

At least 19 recordsLinked to original sources

Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes

The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.

astro-ph.CO

Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments

The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.

astro-ph.CO

A detection system to measure muon-induced neutrons for direct Dark Matter searches

Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.

astro-ph.IM

Monitoring of the thermal neutron flux in the LSM underground laboratory

This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$π$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $Φ_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.

astro-ph.IM

First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.

astro-ph.CO

A new high-background-rejection dark matter Ge cryogenic detector

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $β$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.

astro-ph.IM

Proceedings of the 1st International Workshop "Radiopure Scintillators for EURECA" (RPScint'2008)

Workshop RPSCINT'2008 was organized in Kyiv (Ukraine) on 9th and 10th September 2008. The idea was to bring together physicists, chemists, crystal scintillator experts and manufacturers to discuss the requirements of low-count rate experiments, in particular the required radiopurity and scintillation properties; selection and screening of input materials; purification of materials; raw compound preparation; crystal growing, annealing and handling; test of crystals; search for and development of new scintillating materials. Some contributions to the RPSCINT 2008 workshop are presented in these proceedings.

nucl-ex

Observational constraints of a Milne Universe

The Standard Model of cosmology states a surprising composition of the Universe, in which ordinary matter accounts for less than 5%. The remaining 95% are composed of ~70% Dark Energy and ~25% Dark Matter. However, those two components have never been identified and remain a challenging problem to modern cosmology. One alternative to the concordance model could be the symmetric Milne universe, composed of matter and antimatter (supposed to have negative mass) in equal quantities. We will present the effects of these hypothesis on classical cosmological tests such as primordial nucleosynthesis, CMB, or Type Ia supernovae and show that this model is in remarkably good agreement with observations.

astro-ph

Gravitation, C, P and T symmetries and the Second Law

The intimate links between gravitation and the second law are summarized and two less known relations between gravity and thermodynamics are studied. Firstly, the information cost required to operate a Maxwell's demon on a curved spacetime is estimated using the Kolmogorov-Sinai entropy. More importantly, the charge and time (C and T) reversal properties of the Kerr-Newman solution in General relativity show that this solution, similarly to the Dirac equation, appears to represent both a particle and its antiparticle and suggests a definition of antimatter in general relativity. This definition leads to a parameter free explanation of the cosmological constant term observed in the supernovae data. The relation of this definition of antimatter with the coupled systems through opposite time arrows studied by Schulman is also emphasized.

astro-ph

Identification of backgrounds in the EDELWEISS-I dark matter search experiment

This paper presents our interpretation and understanding of the different backgrounds in the EDELWEISS-I data sets. We analyze in detail the several populations observed, which include gammas, alphas, neutrons, thermal sensor events and surface events, and try to combine all data sets to provide a coherent picture of the nature and localisation of the background sources. In light of this interpretation, we draw conclusions regarding the background suppression scheme for the EDELWEISS-II phase.

astro-ph

Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils

The heat quenching factor Q' (the ratio of the heat signals produced by nuclear and electron recoils of equal energy) of the heat-and-ionization germanium bolometers used by the EDELWEISS collaboration has been measured. It is explained how this factor affects the energy scale and the effective quenching factor observed in calibrations with neutron sources. This effective quenching effect is found to be equal to Q/Q', where Q is the quenching factor of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q' is combined with values of Q obtained from a review of all available measurements of this quantity in tagged neutron beam experiments. The systematic uncertainties associated with this method to evaluate Q' are discussed in detail. For recoil energies between 20 and 100 keV, the resulting heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the contributions from the Q and Q/Q' measurements, respectively. The present compilation of Q values and evaluation of Q' represent one of the most precise determinations of the absolute energy scale for any detector used in direct searches for dark matter.

astro-ph

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a discrimination method using the different time distribution of scintillation light generated in electron recoil and nuclear recoil interactions. We show that the methodology followed both for the calibration of the ZEPLIN-I detector response and for the estimation of the discrimination power is not reliable enough to claim any background discrimination at the present stage. The ZEPLIN-I sensitivity appears then to be in the order of 10$^{-3}$ picobarn, three orders of magnitude above the claimed 1.1 10$^{-6}$ picobarn.

astro-ph

Final results of the EDELWEISS-I dark matter search with cryogenic heat-and-ionization Ge detectors

The final results of the EDELWEISS-I dark matter search using cryogenic heat-and-ionization Ge detectors are presented. The final data sample corresponds to an increase by a factor five in exposure relative to the previously published results. A recoil energy threshold of 13 keV or better was achieved with three 320g detectors working simultaneously over four months of stable operation. Limits on the spin-independent cross-section for the scattering of a WIMP on a nucleon are derived from an accumulated fiducial exposure of 62 kg.d.

astro-ph

Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions

The EDELWEISS collaboration is searching for WIMP dark matter using natural Ge cryogenic detectors. The whole data set of the first phase of the experiment contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present (7.8%), high-spin Ge isotope. The sensitivity of the experiment to the spin-dependent WIMP-nucleon interactions is evaluated using the model-independent framework proposed by Tovey et al.

astro-ph

Improved Exclusion Limits from the EDELWEISS WIMP Search

The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a heat-and-ionization cryogenic Ge detector operated in the low-background environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel, during an effective exposure of 7.4 kg.days. This result is combined with the previous EDELWEISS data to derive a limit on the cross-section for spin-independent interaction of WIMPs and nucleons as a function of WIMP mass, using standard nuclear physics and astrophysical assumptions. This limit excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first sample of supersymmetric models are also excluded at 90%CL.

astro-ph

320g Ionization-Heat Cryogenic Detector for Dark Matter Search in the EDELWEISS Experiment

The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more than 4 times the mass of previous detectors. Calibrations of this detector are used to determine its energy resolution and fiducial volume, and to optimize the detector design for the 1kg phase of the EDELWEISS-I experiment. Analysis of the calibrations and characteristics of a first series of 320g-detectors are presented.

astro-ph

First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector

The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-independent interaction of WIMPs and nucleons are set in the framework of the Minimal Supersymmetric Standard Model (MSSM). The central value of the signal reported by the experiment DAMA is excluded at 90% CL.

astro-ph