SearcharxivSearch

arXiv subjects

G. Feldman

Publications and source records attributed to G. Feldman.

At least 19 recordsLinked to original sources

Proton Compton Scattering from Linearly Polarized Gamma Rays

Differential cross sections for Compton scattering from the proton have been measured at scattering angles of $55^\circ$, $90^\circ$, and $125^\circ$ in the laboratory frame using quasimonoenergetic linearly (circularly) polarized photon beams with a weighted mean energy value of 83.4\,MeV (81.3\,MeV). These measurements were performed at the High Intensity Gamma-Ray Source facility at the Triangle Universities Nuclear Laboratory. The results are compared to previous measurements and are interpreted in the chiral effective field theory framework to extract the electromagnetic dipole polarizabilities of the proton, which gives $\alpha_{E1}^p = 13.8\pm1.2_{\rm stat}\pm0.1_{\rm BSR}\pm0.3_{\rm theo}, \beta_{M1}^p = 0.2\mp1.2_{\rm stat}\pm0.1_{\rm BSR}\mp0.3_{\rm theo}$ in units of 10$^{-4}$\, fm$^3$.

nucl-ex

International Workshop on Next Generation Gamma-Ray Source

A workshop on The Next Generation Gamma-Ray Sources sponsored by the Office of Nuclear Physics at the Department of Energy, was held November 17--19, 2016 in Bethesda, Maryland. The goals of the workshop were to identify basic and applied research opportunities at the frontiers of nuclear physics that would be made possible by the beam capabilities of an advanced laser Compton beam facility. To anchor the scientific vision to realistically achievable beam specifications using proven technologies, the workshop brought together experts in the fields of electron accelerators, lasers, and optics to examine the technical options for achieving the beam specifications required by the most compelling parts of the proposed research programs. An international assembly of participants included current and prospective $γ$-ray beam users, accelerator and light-source physicists, and federal agency program managers. Sessions were organized to foster interactions between the beam users and facility developers, allowing for information sharing and mutual feedback between the two groups. The workshop findings and recommendations are summarized in this whitepaper.

nucl-ex

Compton scattering from $^4$He at the TUNL HI$γ$S facility

Differential cross sections for elastic Compton scattering from $^4$He have been measured with high statistical precision at the High Intensity $γ$-ray Source at laboratory scattering angles of $55^\circ$, $90^\circ$, and $125^\circ$ using a quasi-monoenergetic photon beam with a weighted mean energy value of $81.3$ MeV. The results are compared to previous measurements and similar fore-aft asymmetry in the angular distribution of the differential cross sections is observed. This experimental work is expected to strongly motivate the development of effective-field-theory calculations of Compton scattering from $^4$He to fully interpret the data.

nucl-ex

Near-threshold $π^-$ photoproduction on the deuteron

The first experimental investigation of the near-threshold cross section for incoherent $π^-$ photoproduction on the deuteron $γ$ d -> $π^-$ pp is presented. The experimental technique involved detection of the ~131 MeV gamma ray resulting from the radiative capture of photoproduced $π^-$ in the target. The total cross section has been measured using an unpolarized tagged-photon beam, a liquid-deuterium target, and three very large NaI(Tl) spectrometers. The data are compared to theoretical models that give insight into the elementary reaction $γ$ n -> $π^-$ p and pion-nucleon and nucleon-nucleon final-state interactions.

nucl-ex

Compton Scattering from the Deuteron above Pion-Production Threshold

The electromagnetic polarizabilities of the nucleon are fundamental nucleon-structure observables that characterize its response to external electromagnetic fields. The neutron polarizabilities can be accessed from Compton-scattering data on light nuclear targets. Recent measurements of the differential cross section for Compton scattering on the deuteron below the pion-production threshold have decreased the uncertainties in the neutron polarizabilities, yet the proton polarizabilities remain known substantially more accurately. As the sensitivity of the cross section to the polarizabilities increases with incident photon energy, measurements above the pion threshold may offer a way for an improved determination of the neutron polarizabilities. In this article, the first measurement of the cross section for Compton scattering on the deuteron above the pion-production threshold is presented.

nucl-ex

New Measurement of Compton Scattering from the Deuteron and an Improved Extraction of the Neutron Electromagnetic Polarizabilities

The electromagnetic polarizabilities of the nucleon are fundamental properties that describe its response to external electric and magnetic fields. They can be extracted from Compton-scattering data --- and have been, with good accuracy, in the case of the proton. In contradistinction, information for the neutron requires the use of Compton scattering from nuclear targets. Here we report a new measurement of elastic photon scattering from deuterium using quasimonoenergetic tagged photons at the MAX IV Laboratory in Lund, Sweden. These first new data in more than a decade effectively double the world dataset. Their energy range overlaps with previous experiments and extends it by 20 MeV to higher energies. An analysis using Chiral Effective Field Theory with dynamical Δ(1232) degrees of freedom shows the data are consistent with and within the world dataset. After demonstrating that the fit is consistent with the Baldin sum rule, extracting values for the isoscalar nucleon polarizabilities and combining them with a recent result for the proton, we obtain the neutron polarizabilities as α_n = [11.55 +/- 1.25(stat) +/- 0.2(BSR) +/- 0.8(th)] X 10^{-4} fm^3 and β_n = [3.65 -/+ 1.25(stat) +/- 0.2(BSR) -/+ 0.8(th)] X 10^{-4} fm3, with χ^2 = 45.2 for 44 degrees of freedom.

nucl-ex

Compton Scattering from \nuc{6}{Li} at 86 MeV

Cross sections for \nuc{6}{Li}($γ$,$γ$)\nuc{6}{Li} have been measured at the High Intensity Gamma-Ray Source (\HIGS) and the sensitivity of these cross sections to the nucleon isoscalar polarizabilities was studied. Data were collected using a quasi-monoenergetic 86 MeV photon beam at photon scattering angles of 40$^{\circ}$--160$^{\circ}$. These results are an extension of a previous measurement at a lower energy. The earlier work indicated that the \nuc{6}{Li}($γ$,$γ$)\nuc{6}{Li} reaction at 60 MeV provides a means of extracting the nucleon polarizabilities; this work demonstrates that the sensitivity of the cross section to the polarizabilities is increased at 86 MeV. A full theoretical treatment is needed to verify this conclusion and produce values of the polarizabilities.

nucl-ex

Compton scattering from 12C using tagged photons in the energy range 65 - 115 MeV

Elastic scattering of photons from 12C has been investigated using quasi-monoenergetic tagged photons with energies in the range 65 - 115 MeV at laboratory angles of 60 deg, 120 deg, and 150 deg at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the 12C(g,g)12C cross section to the bound-nucleon polarizabilities.

nucl-ex

Parameters Affecting Temporal Resolution of Time Resolved Integrative Optical Neutron Detector (TRION)

The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF), it integrates the detector signal during a well-defined neutron Time of Flight window corresponding to a pre-selected energy bin, e.g., the energy-interval spanning a cross-section resonance of an element such as C, O and N. The integrative characteristic of the detector permits loss-free operation at very intense, pulsed neutron fluxes, at a cost however, of recorded temporal resolution degradation. This work presents a theoretical and experimental evaluation of detector related parameters which affect temporal resolution of the TRION system.

physics.ins-det

On a functional equation appearing in characterization of distributions by the optimality of an estimate

Let $X$ be a second countable locally compact Abelian group containing no subgroup topologically isomorphic to the circle group $\mathbb{T}$. Let $μ$ be a probability distribution on $X$ such that its characteristic function $\hatμ(y)$ does not vanish and $\hatμ(y)$ for some $n \geq 3$ satisfies the equation $$ \prod_{j=1}^{n} \hatμ(y_j + y) = \prod_{j=1}^{n}\hatμ(y_j - y), \quad \sum_{j=1}^{n} y_j = 0, \quad y_1,\dots,y_n,y \in Y. $$ Then $μ$ is a convolution of a Gaussian distribution and a distribution supported in the subgroup of $X$ generated by elements of order 2.

math.PR

Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory

Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.

physics.ins-det

Development of an LED reference light source for calibration of radiographic imaging detectors

A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off-line image processing. We have investigated parameters influencing the stability of LEDs and developed procedures and criteria to prepare and select LEDs suitable for delivering stable light outputs for several 100 h of operation.

physics.ins-det

A Dual-Purpose Ion-Accelerator for Nuclear-Reaction-Based Explosives-and SNM-Detection in Massive Cargo

A dual-purpose ion-accelerator concept, capable of serving as radiation source in a versatile, nuclear-reaction-based cargo inspection system, is presented. The system will automatically and reliably detect small, operationally-relevant quantities of concealed explosives and special nuclear materials (SNM). It will be cost-effective, employing largely-common hardware, but different reactions/DAQ-modes. Typical expected throughput is 10-20 aviation containers/hr. PACS: 25.20.Dc; 25.40.Ny; 27.20.+n; 29.27.Fh; 79.77.+g; 89.20.Bb; 89.20.Dd Keywords: Cargo inspection; Nuclear-reaction-based methods; Explosives detection; SNM detection

nucl-ex

A measurement of the differential cross section for the two-body photodisintegration of 3He at theta_LAB = 90deg using tagged photons in the energy range 14 -- 31 MeV

The two-body photodisintegration of 3He has been investigated using tagged photons with energies from 14 -- 31 MeV at MAX-lab in Lund, Sweden. The two-body breakup channel was unambiguously identified by the (nonsimultaneous) detection of both protons and deuterons. This approach was made feasible by the over-determined kinematic situation afforded by the tagged-photon technique. Proton- and deuteron-energy spectra were measured using four silicon surface-barrier detector telescopes located at a laboratory angle of 90deg with respect to the incident photon-beam direction. Average statistical and systematic uncertainties of 5.7% and 6.6% in the differential cross section were obtained for 11 photon-energy bins with an average width of 1.2 MeV. The results are compared to previous experimental data measured at comparable photon energies as well as to the results of two recent Faddeev calculations which employ realistic potential models and take into account three-nucleon forces and final-state interactions. Both the accuracy and precision of the present data are improved over the previous measurements. The data are in good agreement with most of the previous results, and favor the inclusion of three-nucleon forces in the calculations.

nucl-ex

High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy

Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing the Time-of-Flight (TOF) method, such a detector is capable of simultaneously capturing several images, each at a different neutron energy (TOF). In addition, a gamma-ray image can also be simultaneously registered, allowing combined neutron/gamma inspection of objects. This permits combining the sensitivity of the fast-neutron resonance method to low-Z elements with that of gamma radiography to high-Z materials.

physics.ins-det

Signal and Noise Analysis in TRION -Time-Resolved Integrative Optical Fast Neutron Detector

TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters, all the processes that influence the signal and noise in the TRION detector. In contrast to event-counting detectors where the signal-to-noise ratio is dependent only on the number of detected events (quantum noise), in an energy-integrating detector additional factors, such as the fluctuations in imparted energy, number of photoelectrons, system gain and other factors will contribute to the noise. The excess noise factor (over the quantum noise) due to these processes was 4.3, 2.7, 2.1, 1.9 and 1.9 for incident neutron energies of 2, 4, 7.5, 10 and 14 MeV, respectively. It is shown that, even under ideal light collection conditions, a fast neutron detection system operating in an integrative mode cannot be quantum-noise-limited due to the relatively large variance in the imparted proton energy and the resulting scintillation light distributions.

physics.ins-det

A Pair Polarimeter for Linearly Polarized High Energy Photons

A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing power of 20% and an efficiency of 0.02%. The layout and first results of a polarimeter test on the laser back-scattering photon beam at SPring-8/LEPS are presented.

physics.ins-det

Time-resolved fast neutron imaging: simulation of detector performance

We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.

physics.ins-det