SearcharxivSearch

arXiv subjects

G. Gabrielse

Publications and source records attributed to G. Gabrielse.

At least 19 recordsLinked to original sources

Compact Actively-Shielded Magnetic Field Coil within Mu-Metal Shields for ACME Electric Dipole Moment Measurements

A system of actively-shielded coils and mu-metal shields is devised, constructed and shown to provide the stable and spatially uniform magnetic field needed for the ACME III electron electric dipole moment (eEDM) measurement. Two layers of current-carrying coils, enclosed within three layers of ferromagnetic shields, produce a field that varies by less than 1 nT (10 $\uG$) within the 1 m $\times$ 4.2 cm $\times$ 4.2 cm interior volume in which a beam of ThO molecules are probed as they precess. The demountable shields are constructed from rectangular mu-metal plates. The largest, with a mass of 19 kg and an area of 2.18 m $\times$ 0.75 m, is easily carried by two people and just fits within a large available annealing oven. The assembly design facilitates low-stress mounting and handling to suppress changes in the magnetic properties of the mu metal, and also provides modular access to apparatus within the coils for maintenance and upgrades. The nearly static external ambient field is reduced within the shielded precession volume by up to a factor of $10^5$. During the magnetic field reversals that ACME uses to suppress systematic uncertainties, the ``actively-shielded'' coil largely cancels out its external fringing field to minimize the magnetization of the mu metal. Even though the shields are only 10 cm outside the coils, shield degaussing after every magnetic field reversal is not required. The non-reversing residual field stays below 1 nT for up to 17 hours when the field is reversed every 30 seconds, for example. The measured performance, compared to the previous generation ACME II apparatus, suggests that the magnetic-field-related systematic uncertainties for ACME III will be smaller by an estimated factor of 40 despite a five times longer precession volume and the use of three magnetic shielding layers rather than five.

physics.atom-ph

One-Positron Quantum Cyclotron

A one-positron quantum cyclotron is realized with a single positron suspended indefinitely in the magnetic field of a Penning trap. This opens the possibility of quantum measurements of the positron magnetic moment at a precision much higher than attained with classical cyclotron motion. Comparing the magnetic moments measured using positron and electron quantum cyclotrons should provide the most stringent test of the fundamental CPT invariance of the Standard Model of particle physics in the lepton sector.

physics.ins-det

SiPM module for the ACME III electron EDM search

This report shows the design and the performance of a large area Silicon Photomultiplier (SiPM) module developed detection of fluorescent light emitted from a 10 cm scale volume. The module was optimized for the planned ACME III electron electric dipole moment (eEDM) search, which will be a powerful probe for the existence of physics beyond the Standard Model of particle physics. The ACME experiment searched for the eEDM with the world's highest sensitivity using cold ThO polar molecules (ACME II). In ACME III, SiPMs will be used for detection of fluorescent photons (the fundamental signal of the experiment) instead of PMTs, which were used in the previous measurement. We have developed an optimized SiPM module, based on a 16-channel SiPM array. Key operational parameters are characterized, including gain and noise. The SiPM dark count rate, background light sensitivity, and optical crosstalk are found to all be well suppressed and more than sufficient for the ACME III application.

physics.ins-det

Measurement of the Electron Magnetic Moment

The electron magnetic moment,$-\mu/\mu_B = g/2 = 1.001 \, 159 \, 652 \, 180 \, 59 \, (13) \, [0.13\, \rm{ppt}]$, is determined 2.2 times more accurately than the value that stood for 14 years. The most precisely determined property of an elementary particle tests the most precise prediction of the Standard Model (SM) to $1$ part in $10^{12}$. The test would improve an order of magnitude if the uncertainty from discrepant measurements of the fine structure constant $\alpha$ is eliminated since the SM prediction is a function of $\alpha$. The new measurement and SM theory together predict $\alpha^{-1}=137.035 \, 999 \, 166 \, (15) \, [0.11 \, \rm{ppb}]$ with an uncertainty ten times smaller than the current disagreement between measured $\alpha$ values.

physics.atom-ph

A self-calibrating polarimeter to measure Stokes parameters

An easily constructed and operated polarimeter precisely determines the relative Stokes parameters that characterize the polarization of laser light. The polarimeter is calibrated in situ without removing or realigning its optical elements, and it is largely immune to fluctuations in the laser beam intensity. The polarimeter's usefulness is illustrated by measuring thermally-induced birefringence in the indium-tin-oxide coated glass field plates used to produce a static electric field in the ACME collaboration's measurement of the electron electric dipole moment.

physics.ins-det

Switchable Damping for a One-Particle Oscillator

The possibility to switch the damping rate for a one-electron oscillator is demonstrated, for an electron that oscillates along the magnetic field axis in a Penning trap. Strong axial damping can be switched on to allow this oscillation to be used for quantum nondemolition detection of the cyclotron and spin quantum state of the electron. Weak axial damping can be switched on to circumvent the backaction of the detection motion that has limited past measurements. The newly developed switch will reduce the linewidth of the cyclotron transition of one-electron by two orders of magnitude.

quant-ph

Searches for new sources of CP violation using molecules as quantum sensors

We discuss how molecule-based searches offer complementary probes to study the violation of fundamental symmetries. These experiments have the potential to probe not only the electron EDM, but also hadronic CPV phenomena. Future experimental developments will offer generic sensitivity to probe flavor neutral sources of both leptonic and hadronic CPV at scales of $\geq$ 100 TeV, and flavor changing CPV at scales of $\geq$ 1000 TeV.

hep-ph

Two-Symmetry Penning-Ioffe Trap for Antihydrogen Cooling and Spectroscopy

High-accuracy spectroscopic comparisons of trapped antihydrogen atoms ($\overline{\text{H}}$) and hydrogen atoms ($\text{H}$) promise to stringently test the fundamental CPT symmetry invariance of the standard model of particle physics. ATRAP's nested Penning-Ioffe trap was developed for such studies. The first of its unique features is that its magnetic Ioffe trap for $\overline{\text{H}}$ atoms can be switched between quadrupole and octupole symmetries. The second is that it allows laser and microwave access perpendicular to the central axis of the traps.

physics.ins-det

Attaining the shot-noise-limit in the ACME measurement of the electron electric dipole moment

Experimental searches for the electron electric dipole moment, $d_e$, probe new physics beyond the Standard Model. Recently, the ACME Collaboration set a new limit of $|d_e| <1.1\times 10^{-29}$ $e\cdot \textrm{cm}$ [Nature $\textbf{562}$, 355 (2018)], constraining time reversal symmetry (T) violating physics in the 3-100 TeV energy scale. ACME extracts $d_e$ from the measurement of electron spin precession due to the thorium monoxide (ThO) molecule's internal electric field. This recent ACME II measurement achieved an order of magnitude increased sensitivity over ACME I by reducing both statistical and systematic uncertainties in the measurement of the electric dipole precession frequency. The ACME II statistical uncertainty was a factor of 1.7 above the ideal shot-noise limit. We have since traced this excess noise to timing imperfections. When the experimental imperfections are eliminated, we show that shot noise limit is attained by acquiring noise-free data in the same configuration as ACME II.

physics.atom-ph

Towards an Improved Test of the Standard Model's Most Precise Prediction

The electron and positron magnetic moments are the most precise prediction of the standard model of particle physics. The most accurate measurement of a property of an elementary particle has been made to test this result. A new experimental method is now being employed in an attempt to improve the measurement accuracy by an order of magnitude. Positrons from a "student source" now suffice for the experiment. Progress toward a new measurement is summarized.

quant-ph

Gaseous $^3$He Nuclear Magnetic Resonance Probe for Cryogenic Environments

Normal nuclear magnetic resonance (NMR) probes cannot be used to make high frequency resolution measurements in a cryogenic environment because they lose their frequency resolution when the liquid sample in the probe freezes. A gaseous $^3$He NMR probe, designed and constructed to work naturally in such cryogenic environments, is demonstrated at 4.2 K and 5.3 Tesla to have a frequency resolution better than 0.4 part per billion. As a demonstration of its usefulness, the cryogenic probe is used to shim a superconducting solenoid with a cryogenic interior to produce a magnetic field with a high spatial homogeneity, and to measure the magnetic field stability.

physics.atom-ph

STIRAP preparation of a coherent superposition of ThO $H^3Δ_1$ states for an improved electron EDM measurement

Experimental searches for the electron electric dipole moment (EDM) probe new physics beyond the Standard Model. The current best EDM limit was set by the ACME Collaboration [Science \textbf{343}, 269 (2014)], constraining time reversal symmetry ($T$) violating physics at the TeV energy scale. ACME used optical pumping to prepare a coherent superposition of ThO $H^3Δ_1$ states that have aligned electron spins. Spin precession due to the molecule's internal electric field was measured to extract the EDM. We report here on an improved method for preparing this spin-aligned state of the electron by using STIRAP. We demonstrate a transfer efficiency of $75\pm5\%$, representing a significant gain in signal for a next generation EDM experiment. We discuss the particularities of implementing STIRAP in systems such as ours, where molecular ensembles with large phase-space distributions are transfered via weak molecular transitions with limited laser power and limited optical access.

physics.atom-ph

High Efficiency Positron Accumulation for High-Precision Measurements

Positrons are accumulated within a Penning trap designed to make more precise measurements of the positron and electron magnetic moments. The retractable radioactive source used is weak enough to require no license for handling radioactive material and the radiation dosage one meter from the source gives an exposure several times smaller than the average radiation dose on the earth's surface. The 100 mK trap is mechanically aligned with the 4.2 K superconducting solenoid that produces a 6 tesla magnetic trapping field with a direct mechanical coupling.

physics.ins-det

Zeeman interaction in ThO $H^3Δ_1$ for the electron EDM search

The current limit on the electron's electric dipole moment, $|d_\mathrm{e}|<8.7\times 10^{-29} e {\cdotp} {\rm cm}$ (90% confidence), was set using the molecule thorium monoxide (ThO) in the $J=1$ rotational level of its $H ^3Δ_1$ electronic state [Science $\bf 343$, 269 (2014)]. This state in ThO is very robust against systematic errors related to magnetic fields or geometric phases, due in part to its $Ω$-doublet structure. These systematics can be further suppressed by operating the experiment under conditions where the $g$-factor difference between the $Ω$-doublets is minimized. We consider the $g$-factors of the ThO $H^3Δ_1$ state both experimentally and theoretically, including dependence on $Ω$-doublets, rotational level, and external electric field. The calculated and measured values are in good agreement. We find that the $g$-factor difference between $Ω$-doublets is smaller in $J=2$ than in $J=1$, and reaches zero at an experimentally accessible electric field. This means that the $H,J=2$ state should be even more robust against a number of systematic errors compared to $H,J=1$.

physics.atom-ph

Shot-noise-limited spin measurements in a pulsed molecular beam

Heavy diatomic molecules have been identified as good candidates for use in electron electric dipole moment (eEDM) searches. Suitable molecular species can be produced in pulsed beams, but with a total flux and/or temporal evolution that varies significantly from pulse to pulse. These variations can degrade the experimental sensitivity to changes in spin precession phase of an electri- cally polarized state, which is the observable of interest for an eEDM measurement. We present two methods for measurement of the phase that provide immunity to beam temporal variations, and make it possible to reach shot-noise-limited sensitivity. Each method employs rapid projection of the spin state onto both components of an orthonormal basis. We demonstrate both methods using the eEDM-sensitive H state of thorium monoxide (ThO), and use one of them to measure the magnetic moment of this state with increased accuracy relative to previous determinations.

physics.atom-ph

Resolving an Individual One-Proton Spin Flip to Determine a Proton Spin State

Previous measurements with a single trapped proton or antiproton detected spin resonance from the increased scatter of frequency measurements caused by many spin flips. Here a measured correlation confirms that individual spin transitions and states are detected instead. The high fidelity suggests that it may be possible to use quantum jump spectroscopy to measure the p and \pbar magnetic moments much more precisely.

physics.atom-ph

One-Particle Measurement of the Antiproton Magnetic Moment

\DeclareRobustCommand{\pbar}{\HepAntiParticle{p}{}{}\xspace} \DeclareRobustCommand{\p}{\HepParticle{p}{}{}\xspace} \DeclareRobustCommand{\mup}{$\mu_{p}${}{}\xspace} \DeclareRobustCommand{\mupbar}{$\mu_{\pbar}${}{}\xspace} \DeclareRobustCommand{\muN}{$\mu_N${}{}\xspace For the first time a single trapped \pbar is used to measure the \pbar magnetic moment ${\bm\mu}_{\pbar}$. The moment ${\bm\mu}_{\pbar} = \mu_{\pbar} {\bm S}/(\hbar/2)$ is given in terms of its spin ${\bm S}$ and the nuclear magneton (\muN) by $\mu_{\pbar}/\mu_N = -2.792\,845 \pm 0.000\,012$. The 4.4 parts per million (ppm) uncertainty is 680 times smaller than previously realized. Comparing to the proton moment measured using the same method and trap electrodes gives $\mu_{\pbar}/\mu_p = -1.000\,000 \pm 0.000\,005$ to 5 ppm, for a proton moment ${\bm{\mu}}_{p} = \mu_{p} {\bm S}/(\hbar/2)$, consistent with the prediction of the CPT theorem.

physics.atom-ph

Direct Measurement of the Proton Magnetic Moment

The proton magnetic moment in nuclear magnetons is measured to be $\mu_p/\mu_N \equiv g/2 = 2.792\,846 \pm 0.000\,007$, a 2.5 ppm (parts per million) uncertainty. The direct determination, using a single proton in a Penning trap, demonstrates the first method that should work as well with an antiproton as with a proton. This opens the way to measuring the antiproton magnetic moment (whose uncertainty has essentially not been reduced for 20 years) at least $10^3$ times more precisely.

physics.atom-ph