The nEXO Radioassay Program

Material radioactivity compilations, such as the one presented here, are important enablers of science. They are useful for the selection of radiopure materials used in the design and construction of low-energy rare-event search experiments. They allow researchers developing such experiments to save time on material studies and avoid costly duplication of effort. The data presented here were generated in support of the planned nEXO double-beta decay search. This work contains among the most restrictive constraints on the natural radioactivity content of materials of general interest to the low-radioactivity community, found in any tabulation of this kind. In this study, various techniques were employed; they are described here.

physics.ins-det

Mortality of ultra-thin LGADs and PiN diodes from high energy deposition

Low Gain Avalanche Diodes are prime candidates for high-resolution timing applications in High Energy Physics, Nuclear science, and several other fields. Operating these devices in high-radiation environments presents various hazards, including the risk of their permanent degradation or destruction caused by effects such as Single Event Burnout. Studies using minimum ionizing particles found a greatly reduced Single Event Burnout risk by operating below a bias voltage corresponding to an average electric field of 12 V/$\mu$m - however, as high energy particle colliders produce a wide energy spectrum of radiation, it is crucial to understand this phenomenon and other possible damage mechanisms at energy deposition levels greater than those of minimum ionizing particles. This was achieved by pre-irradiating LGADs and PiN diodes with active thicknesses of 20, 30, and 50 $\mu$m up to 1.5 $\times$ 10$^{15}$ $\mathrm{n_{eq}/cm^2}$, and exposing them to beams of protons and heavy ions (C, O, Fe, Au) at the BNL Tandem van de Graaff accelerator. Several mortality categories were observed, defined by different electrical and mechanical damage signatures. This furthers our understanding of permanent radiation damage of silicon devices, crucial towards mitigating Single Event Burnout and other damage mechanisms to safely operate future detectors.

physics.ins-det

Sensitivity of nEXO to $^{136}$Xe Charged-Current Interactions: Background-free Searches for Solar Neutrinos and Fermionic Dark Matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, $\nu_e + ^{136}$Xe$\rightarrow ^{136}$Cs$^* + e^-$, as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of $^{136}$Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of $10^{-9}$, enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of CNO solar neutrinos with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement towards addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the $^7$Be neutrinos with a precision of $\sigma \leq 1.5$ keV and could determine the survival probability of $^{7}$Be and $pep$ solar $\nu_e$ with precision comparable to state-of-the-art. These quantities are sensitive to the Sun's core temperature and to non-standard neutrino interactions, respectively. Furthermore, the strong background suppression would allow nEXO to search for for charged-current interactions of fermionic dark matter in the mass range $m_\chi$ = $0.668$-$7$ MeV with a sensitivity up to three orders of magnitude better than current limits.

nucl-ex

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $\mu$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

physics.ins-det

European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment

PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/\mu}$ to 1 part in $10^4$, improving the current experimental result $R_{e/\mu}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/\mu}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.

hep-ex

Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

physics.atom-ph

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was 11-2, with a nominal beam size of 3 cm x 0.5 cm, a repetition rate of 500 MHz, and very monochromatic. LGADs of different thicknesses and gain layer configurations were read out using fast amplification boards and digitized with a fast oscilloscope. Standard PiN devices were characterized as well. The devices' energy resolution and time resolution as a function of X-ray energy were measured. The charge collection and multiplication mechanism were simulated using TCAD Sentaurus, and the results were compared with the collected data.

physics.ins-det

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.

physics.ins-det

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

Solid State Detectors and Tracking for Snowmass

Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).

physics.ins-det

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. In this paper, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the HL-LHC. Signal generated by either betas from a $^{90}$Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

physics.ins-det

Electronics for Fast Timing

Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors

physics.ins-det

NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity

The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

nucl-ex

Development of a $^{127}$Xe calibration source for nEXO

We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

physics.ins-det

X-Ray Silicon Drift Detector-CMOS Front-End System with High Energy Resolution at Room Temperature

We present a spectroscopic system constituted by a Silicon Drift Detector (SDD) coupled to a CMOS charge sensitive preamplifier, named SIRIO, specifically designed to reach ultimate low noise levels. The SDD, with an active area of 13 mm , has been manufactured by optimizing the production processes in order to reduce the anode current, successfully reaching current densities between 17 pA/cm and 25 pA/cm at 20 for drift fields ranging from 100 V/cm to 500 V/cm. The preamplifier shows minimum intrinsic noise levels of 1.27 and 1.0 electrons r.m.s. at 20 and 30 , respectively. At room temperature ( ) the 5.9 keV and the pulser lines have 136 eV and 64 eV FWHM, respectively, corresponding to an equivalent noise charge of 7.4 electrons r.m.s.; the noise threshold is at 165 eV. The energy resolution, as measured on the pulser line, ranges from 82 eV FWHM (9.4 electrons r.m.s.) at 30C down to 29 eV FWHM (3.3 electrons r.m.s.) at 30C .

physics.ins-det

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

physics.ins-det

Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage

nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.

physics.ins-det

Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)

To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.

physics.ins-det