SearcharxivSearch

arXiv subjects

G. Grauso

Publications and source records attributed to G. Grauso.

7 recordsLinked to original sources

Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide programme

Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass WIMP interactions, setting new world-leading constraints in the 1-3 GeV/c^2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.

hep-ex

Measurement of the X-ARAPUCA's Absolute Photon Detection Efficiency for the Deep Underground Neutrino Experiment's Vertical Drift Far Detector

The DUNE experiment will implement a photon detection system composed of X-ARAPUCA (XA) devices. These trap incoming VUV photons by internal reflection in a wavelength shifter light guide to be collected onto silicon photomultiplier arrays, sensitive to visible light. In the baseline design, dichroic filters are used to prevent photons from escaping. The configuration proposed for DUNE's Vertical Drift (VD) module has been characterised in liquid argon for the first time using dedicated cryogenic setups developed at CIEMAT and INFN Naples. Additionally, several alternative configurations, based on the design optimisation studies of an R&D campaign, have been evaluated. The results show an efficiency of up to 4.5$\pm$4~% at 4.5~V overvoltage, representing a significant improvement over previous XA implementations. Most notably, configurations without dichroic filters show an improvement of up to 18~%, attributed to transmittance losses in the dichroic filters.

physics.ins-det

Quality Assurance and Quality Control of the $26~\text{m}^2$ SiPM production for the DarkSide-20k dark matter experiment

DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with \SI{50} {tonnes} of low radioactivity underground argon (UAr) acting as the WIMP target. NUV-HD-cryo Silicon Photomultipliers (SiPM)s designed by Fondazione Bruno Kessler (FBK) (Trento, Italy) were selected as the photon sensors covering two $10.5~\text{m}^2$ Optical Planes, one at each end of the TPC, and a total of $5~\text{m}^2$ photosensitive surface for the liquid argon veto detectors. This paper describes the Quality Assurance and Quality Control (QA/QC) plan and procedures accompanying the production of FBK~NUV-HD-cryo SiPM wafers manufactured by LFoundry s.r.l. (Avezzano, AQ, Italy). SiPM characteristics are measured at 77~K at the wafer level with a custom-designed probe station. As of March~2025, 1314 of the 1400 production wafers (94% of the total) for DarkSide-20k were tested. The wafer yield is $93.2\pm2.5$\%, which exceeds the 80\% specification defined in the original DarkSide-20k production plan.

physics.ins-det

Directionality of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence level

physics.ins-det

X-Arapuca long term test

The photon detection system of the DUNE experiment is based on the X-ARAPUCA light trap. The basic elements of the X-ARAPUCA are the dichroic filters coated with wavelength shifter (para-Therphenyl), a waveshifting plate and an array of SiPMs which detects the trapped photons. A small scale prototype of the X-ARAPUCA has been installed in liquid argon in a dedicated facility at INFN-Napoli and exposed to alpha particles from a source. In order to test the stability of the overall device response the X-ARAPUCA was kept for 10 days in liquid argon continuously purified. The performed tests allowed for a preliminary estimation of the X-ARAPUCA absolute photon detection efficiency.

physics.ins-det

A large facility for photosensors test at cryogenic temperature

Current generation of detectors using noble gases in liquid phase for direct dark matter search and neutrino physics need large area photosensors. Silicon based photo-detectors are innovative light collecting devices and represent a successful technology in these research fields. The DarkSide collaboration started a dedicated development and customization of SiPM technology for its specific needs resulting in the design, production and assembly of large surface modules of 20x20 cm^2 named Photo Detection Unit for the DarkSide-20k experiment. Production of a large number of such devices, as needed to cover about 20 m^2 of active surface inside the DarkSide-20k detector, requires a robust testing and validation process. In order to match this requirement a dedicated test facility for the photosensor test was designed and commissioned at INFN-Naples laboratory. The first commissioning test was successfully performed in 2021. Since then a number of testing campaigns were performed. Detailed description of the facility is reported as well as results of some tests.

physics.ins-det

A versatile cryogenic system for liquid argon detectors

Detectors for direct dark matter search using noble gases in liquid phase as detection medium need to be coupled to liquefaction, purification and recirculation systems. A dedicated cryogenic system has been assembled and operated at the INFN-Naples cryogenic laboratory with the aim to liquefy and purify the argon used as active target in liquid argon detectors to study the scintillation and ionization signals detected by large SiPMs arrays. The cryogenic system is mainly composed of a double wall cryostat hosting the detector, a purification stage to reduce the impurities below one part per billion level, a condenser to liquefy the argon, a recirculation gas panel connected to the cryostat equipped with a custom gas pump. The main features of the cryogenic system are reported as well as the performances, long term operations and stability in terms of the most relevant thermodynamic parameters.

physics.ins-det