Searcharxiv⌕ Search

arXiv subjects

G. Gwinner

Publications and source records attributed to G. Gwinner.

36 records · Page 2Linked to original sources

A Novel Transparent Charged Particle Detector for the CPET Upgrade at TITAN

The detection of an electron bunch exiting a strong magnetic field can prove challenging due to the small mass of the electron. If placed too far from a solenoid's entrance, a detector outside the magnetic field will be too small to reliably intersect with the exiting electron beam because the light electrons will follow the diverging magnetic field outside the solenoid. The TITAN group at TRIUMF in Vancouver, Canada, has made use of advances in the practice and precision of photochemical machining (PCM) to create a new kind of charge collecting detector called the "mesh detector." The TITAN mesh detector was used to solve the problem of trapped electron detection in the new Cooler PEnning Trap (CPET) currently under development at TITAN. This thin array of wires etched out of a copper plate is a novel, low profile, charge agnostic detector that can be made effectively transparent or opaque at the user's discretion.

physics.ins-det↗

Improvements to TITAN's Mass Measurement and Decay Spectroscopy Capabilities

The study of nuclei farther from the valley of $β$-stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore requires innovations in technique in order to keep up. TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) facility deploys three ion traps, with a fourth in the commissioning phase, to perform and support Penning trap mass spectrometry and in-trap decay spectroscopy on some of the shortest-lived nuclei ever studied. We report on recent advances and updates to the TITAN facility since the 2012 EMIS Conference. TITAN's charge breeding capabilities have been improved and in-trap decay spectroscopy can be performed in TITAN's electron beam ion trap (EBIT). Higher charge states can improve the precision of mass measurements, reduce the beam-time requirements for a given measurement, improve beam purity and opens the door to access, via in-trap decay and recapture, isotopes not available from the ISOL method. This was recently demonstrated during TITAN's mass measurement of $^{30}$Al. The EBIT's decay spectroscopy setup was commissioned with a successful branching ratio and half-life measurement of $^{124}$Cs. Charge breeding in the EBIT increases the energy spread of the ion bunch sent to the Penning trap for mass measurement so a new Cooler Penning Trap (CPET), which aims to cool highly charge ions with an electron plasma, is undergoing online commissioning. Already, CPET has demonstrated the trapping and self-cooling of a room-temperature electron plasma which was stored for several minutes. A new detector has been installed inside the CPET magnetic field which will allow for in-magnet charged particle detection.

physics.ins-det↗

Precision mass measurements of magnesium isotopes and implications on the validity of the Isobaric Mass Multiplet Equation

If the mass excess of neutron-deficient nuclei and their neutron-rich mirror partners are both known, it can be shown that deviations of the Isobaric Mass Multiplet Equation (IMME) in the form of a cubic term can be probed. Such a cubic term was probed by using the atomic mass of neutron-rich magnesium isotopes measured using the TITAN Penning trap and the recently measured proton-separation energies of $^{29}$Cl and $^{30}$Ar. The atomic mass of $^{27}$Mg was found to be within 1.6$σ$ of the value stated in the Atomic Mass Evaluation. The atomic masses of $^{28,29}$Mg were measured to be both within 1$σ$, while being 8 and 34 times more precise, respectively. Using the $^{29}$Mg mass excess and previous measurements of $^{29}$Cl we uncovered a cubic coefficient of $d$ = 28(7) keV, which is the largest known cubic coefficient of the IMME. This departure, however, could also be caused by experimental data with unknown systematic errors. Hence there is a need to confirm the mass excess of $^{28}$S and the one-neutron separation energy of $^{29}$Cl, which have both come from a single measurement. Finally, our results were compared to ab initio calculations from the valence-space in-medium similarity renormalization group, resulting in a good agreement.

nucl-ex↗

Hyperfine anomalies in Fr: boundaries of the spherical single particle model

We have measured the hyperfine splitting of the $7P_{1/2}$ state at the 100 ppm level in Fr isotopes ($^{206g,206m, 207, 209, 213, 221}$Fr) near the closed neutron shell ($N$ = 126 in $^{213}$Fr). The measurements in five isotopes and a nuclear isomeric state of francium, combined with previous determinations of the $7S_{1/2}$ splittings, reveal the spatial distribution of the nuclear magnetization, i.e. the Bohr-Weisskopf effect. We compare our results with a simple shell model consisting of unpaired single valence nucleons orbiting a spherical nucleus, and find good agreement over a range of neutron-deficient isotopes ($^{207-213}$Fr). Also, we find near-constant proton anomalies for several even-$ N$ isotopes. This identifies a set of Fr isotopes whose nuclear structure can be understood well enough for the extraction of weak interaction parameters from parity non-conservation studies.

physics.atom-ph↗

Offline trapping of $^{221}$Fr in a magneto-optical trap from implantation of an $^{225}$Ac ion beam

We demonstrate a new technique to prepare an offline source of francium for trapping in a magneto-optical trap. Implanting a radioactive beam of $^{225}$Ac, $t_{1/2} = 9.920(3)$ days, in a foil, allows use of the decay products, i.e.$^{221}$Fr, $t_{1/2} = 288.0(4)$ s. $^{221}$Fr is ejected from the foil by the $α$ decay of $^{225}$Ac. This technique is compatible with the online accumulation of a laser-cooled atomic francium sample for a series of planned parity non-conservation measurements at TRIUMF. We obtain a 34% release efficiency for $^{221}$Fr from the recoil source based on particle detector measurements. We find that laser cooling operation with the source is $8^{+10}_{-5}$ times less efficient than from a mass-separated ion beam of $^{221}$Fr in the current geometry. While the flux of this source is two to three orders of magnitude lower than typical francium beams from ISOL facilities, the source provides a longer-term supply of francium for offline studies.

physics.ins-det↗

Progress towards precision measurements of beta-decay correlation parameters using atom and ion traps

The correlations of the decay products following the beta decay of nuclei have a long history of providing a low-energy probe of the fundamental symmetries of our universe. Over half a century ago, the correlation of the electrons following the decay of polarized 60Co demonstrated that parity is not conserved in weak interactions. Today, the same basic idea continues to be applied to search for physics beyond the standard model: make precision measurements of correlation parameters and look for deviations compared to their standard model predictions. Efforts to measure these parameters to the 0.1% level utilizing atom and ion trapping techniques are described.

physics.ins-det↗

Commissioning of the Francium Trapping Facility at TRIUMF

We report on the successful commissioning of the Francium Trapping Facility at TRIUMF. Large laser-cooled samples of francium are produced from a francium ion beam delivered by the ISAC radioactive ion beam facility. The ion beam is neutralized on an yttrium foil, which is subsequently heated to transfer the atoms into the magneto-optical trapping region. We have successfully trapped $^{207}$Fr, $^{209}$Fr and $^{221}$Fr, with a maximum of $2.5 \times 10^5$ $^{209}$Fr atoms. The neutral cold atoms will be used in studies of the weak interaction through measurements of atomic parity non-conservation.

physics.atom-ph↗

Extinction of the N=20 neutron-shell closure for 32Mg examined by direct mass measurements

The 'island of inversion' around $^{32}$Mg is one of the most important paradigm for studying the disappearance of the stabilizing 'magic' of a shell closure. We present the first Penning-trap mass measurements of the exotic nuclides $^{29-31}$Na and $^{30-34}$Mg, which allow a precise determination of the empirical shell gap for $^{32}$Mg. The new value of 1.10(3) MeV is the lowest observed shell gap for any nuclide with a canonical magic number.

nucl-ex↗

Modern Ives-Stilwell Experiments At Storage Rings: Large Boosts Meet High Precision

We give a brief overview of time dilation tests using high-resolution laser spectroscopy at heavy-ion storage rings. We reflect on the various methods used to eliminate the first-order Doppler effect and on the pitfalls encountered, and comment on possible extensions at future facilities providing relativistic heavy ion beams at $γ\gg 1$.

physics.atom-ph↗

Penning-trap mass spectrometry of highly charged, neutron-rich Rb and Sr isotopes in the vicinity of $A\approx100$

The neutron-rich mass region around $A\approx100$ presents challenges for modeling the astrophysical $r$-process because of rapid shape transitions. We report on mass measurements using the TITAN Penning trap at TRIUMF-ISAC to attain more reliable theoretical predictions of $r$-process nucleosynthesis paths in this region. A new approach using highly charged ($q=15+$) ions has been applied which considerably saves measurement time and preserves accuracy. New mass measurements of neutron-rich $^{94,97,98}$Rb and $^{94,97-99}$Sr have uncertainties of less than 4 keV and show deviations of up to 11$σ$ to previous measurements. An analysis using a parameterized $r$-process model is performed and shows that mass uncertainties for the A=90 abundance region are eliminated.

nucl-ex↗

Highly charged ions in Penning traps, a new tool for resolving low lying isomeric states

The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving power provides a new and unique access to resolving low-lying long-lived ($T_{1/2} > 50$ ms) nuclear isomers. Recently, the $111.19(22)$ keV (determined from $γ$-ray spectroscopy) isomeric state in $^{78}$Rb has been resolved from the ground state, in a charge state of $q=8+$ with the TITAN Penning trap at the TRIUMF-ISAC facility. The excitation energy of the isomer was measured to be $108.7(6.4)$ keV above the ground state. The extracted masses for both the ground and isomeric states, and their difference, agree with the AME2003 and Nuclear Data Sheet values. This proof of principle measurement demonstrates the feasibility of using Penning trap mass spectrometers coupled to charge breeders to study nuclear isomers and opens a new route for isomer searches.

nucl-ex↗

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

nucl-ex↗

Comment on "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions"

In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experimental scheme and reiterate that our results are in excellent agreement with Special Relativity.

physics.atom-ph↗

Standard Model tests with trapped radioactive atoms

We review the use of laser cooling and trapping for Standard Model tests, focusing on trapping of radioactive isotopes. Experiments with neutral atoms trapped with modern laser cooling techniques are testing several basic predictions of electroweak unification. For nuclear $β$ decay, demonstrated trap techniques include neutrino momentum measurements from beta-recoil coincidences, along with methods to produce highly polarized samples. These techniques have set the best general constraints on non-Standard Model scalar interactions in the first generation of particles. They also have the promise to test whether parity symmetry is maximally violated, to search for tensor interactions, and to search for new sources of time reversal violation. There are also possibilites for exotic particle searches. Measurements of the strength of the weak neutral current can be assisted by precision atomic experiments using traps of small numbers of radioactive atoms, and sensitivity to possible time-reversal violating electric dipole moments can be improved.

nucl-ex↗

Tensor interaction constraints from beta decay recoil spin asymmetry of trapped atoms

We have measured the angular distribution of recoiling daughter nuclei emitted from the Gamow-Teller $β$ decay of spin-polarized $^{80}$Rb. The asymmetry of this distribution vanishes to lowest order in the Standard Model (SM) in pure Gamow-Teller decays, producing an observable very sensitive to new interactions. We measure the non-SM contribution to the asymmetry to be $A_{T}$= 0.015 $\pm$ 0.029 (stat) $\pm$ 0.019 (syst), consistent with the SM prediction. We constrain higher-order SM corrections using the measured momentum dependence of the asymmetry, and their remaining uncertainty dominates the systematic error. Future progress in determining the weak magnetism term theoretically or experimentally would reduce the final errors. We describe the resulting constraints on fundamental 4-Fermi tensor interactions.

nucl-ex↗

Recombination rate coefficients for astrophysical applications from storage-ring experiments

The basic approach for measuring electron-ion recombination rate coefficients in merged-beams electron-ion collision experiments at heavy-ion storage rings is outlined. As an example experimental results for the low temperature recombination of C IV ions are compared with the recommended theoretical rate coefficient by Mazzotta et al. The latter deviates by factors of up to 5 from the experimental one.

astro-ph↗

Dielectronic Recombination (via N=2 --> N'=2 Core Excitations) and Radiative Recombination of Fe XX: Laboratory Measurements and Theoretical Calculations

We have measured the resonance strengths and energies for dielectronic recombination (DR) of Fe XX forming Fe XIX via N=2 --> N'=2 (Delta_N=0) core excitations. We have also calculated the DR resonance strengths and energies using AUTOSTRUCTURE, HULLAC, MCDF, and R-matrix methods, four different state-of-the-art theoretical techniques. On average the theoretical resonance strengths agree to within <~10% with experiment. However, the 1 sigma standard deviation for the ratios of the theoretical-to-experimental resonance strengths is >~30% which is significantly larger than the estimated relative experimental uncertainty of <~10%. This suggests that similar errors exist in the calculated level populations and line emission spectrum of the recombined ion. We confirm that theoretical methods based on inverse-photoionization calculations (e.g., undamped R-matrix methods) will severely overestimate the strength of the DR process unless they include the effects of radiation damping. We also find that the coupling between the DR and radiative recombination (RR) channels is small. We have used our experimental and theoretical results to produce Maxwellian-averaged rate coefficients for Delta_N=0 DR of Fe XX. For kT>~1 eV, which includes the predicted formation temperatures for Fe XX in an optically thin, low-density photoionized plasma with cosmic abundances, our experimental and theoretical results are in good agreement. We have also used our R-matrix results, topped off using AUTOSTRUCTURE for RR into J>=25 levels, to calculate the rate coefficient for RR of Fe XX. Our RR results are in good agreement with previously published calculations.

astro-ph↗

Storage ring measurement of the C IV recombination rate coefficient

The low energy C IV dielectronic recombination (DR) rate coefficient associated with 2s-2p Delta n=0 excitations of this lithiumlike ion has been measured with high energy-resolution at the heavy-ion storage-ring TSR of the Max-Planck-Institut fuer Kernphysik in Heidelberg, Germany. The experimental procedure and especially the experimental detection probabilities for the high Rydberg states produced by the recombination of this ion are discussed in detail. From the experimental data a Maxwellian plasma rate coefficient is derived with 15% systematic uncertainty and parameterized for ready use in plasma modeling codes. Our experimental result especially benchmarks the plasma rate coefficient below 10000 K where DR occurs predominantly via C III (1s2 2p 4l) intermediate states and where existing theories differ by orders of magnitude. Furthermore, we find that the total dielectronic and radiative C IV recombination can be represented by the incoherent sum of our DR rate coefficient and the RR rate coefficient of Pequignot et al. (1991, Astron. Astrophys., 251, 680).

astro-ph↗