SearcharxivSearch

arXiv subjects

G. H. Lee

Publications and source records attributed to G. H. Lee.

5 recordsLinked to original sources

Signatures of long-range-correlated disorder in the magnetotransport of ultrathin topological insulators

In an ultrathin topological insulator (TI) film, a hybridization gap opens in the TI surface states, and the system is expected to become either a trivial insulator or a quantum spin Hall insulator when the chemical potential is within the hybridization gap. Here we show, however, that these insulating states are destroyed by the presence of a large and long-range-correlated disorder potential, which converts the expected insulator into a metal. We perform transport measurements in ultrathin, dual-gated topological insulator films as a function of temperature, gate voltage, and magnetic field, and we observe a metallic-like, non-quantized conductivity, which exhibits a weak antilocalization-like cusp at the low magnetic field and gives way to a nonsaturating linear magnetoresistance at large field. We explain these results by considering the disordered network of electron- and hole-type puddles induced by charged impurities. We argue theoretically that such disorder can produce an insulator-to-metal transition as a function of increasing disorder strength, and we derive a condition on the band gap and the impurity concentration necessary to observe the insulating state. We also explain the linear magnetoresistance in terms of strong spatial fluctuations of the local conductivity, using both numerical simulations and a theoretical scaling argument.

cond-mat.mes-hall

A new search for the $K_{L} \to π^0 ν\overlineν$ and $K_{L} \to π^{0} X^{0}$ decays

We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to π^0 ν\overlineν$, in data from the first 100 hours of physics running in 2013 of the J-PARC KOTO experiment. One candidate event was observed while $0.34\pm0.16$ background events were expected. We set an upper limit of $5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level (C.L.). An upper limit of $3.7\times10^{-8}$ at the 90\% C.L. for the $K_{L} \to π^{0} X^{0}$decay was also set for the first time, where $X^{0}$ is an invisible particle with a mass of 135 MeV/$c^{2}$.

hep-ex

Imaging Cyclotron Orbits of Electrons in Graphene

Electrons in graphene can travel for several microns without scattering at low temperatures, and their motion becomes ballistic, following classical trajectories. When a magnetic field B is applied perpendicular to the plane, electrons follow cyclotron orbits. Magnetic focusing occurs when electrons injected from one narrow contact focus onto a second contact located an integer number of cyclotron diameters away. By tuning the magnetic field B and electron density n in the graphene layer, we observe magnetic focusing peaks. We use a cooled scanning gate microscope to image cyclotron trajectories in graphene at 4.2 K. The tip creates a local change in density that casts a shadow by deflecting electrons flowing nearby; an image of flow can be obtained by measuring the transmission between contacts as the tip is raster scanned across the sample. On the first magnetic focusing peak, we image a cyclotron orbit that extends from one point contact to the other. In addition, we study the geometry of orbits deflected into the second point contact by the tip.

cond-mat.mes-hall

Long-lived neutral-kaon flux measurement for the KOTO experiment

The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.

physics.ins-det