SearcharxivSearch

arXiv subjects

G. Heuermann

Publications and source records attributed to G. Heuermann.

At least 19 recordsLinked to original sources

New constraints on cosmic ray-boosted dark matter from the LUX-ZEPLIN experiment

While dual-phase xenon time projection chambers (TPCs) have driven the sensitivity towards weakly interacting massive particles (WIMPs) at the GeV/c^2 to TeV/c^2 mass scale, the scope for sub-GeV/c^2 dark matter particles is hindered by a limited nuclear recoil energy detection threshold. One approach to probe for lighter candidates is to consider cases where they have been boosted by collisions with cosmic rays in the Milky Way, such that the additional kinetic energy lifts their induced signatures above the nominal threshold. In this Letter, we report first results of a search for cosmic ray-boosted dark matter (CRDM) with a combined 4.2 tonne-year exposure from the LUX-ZEPLIN (LZ) experiment. We observe no excess above the expected backgrounds and establish world-leading constraints on the spin-independent CRDM-nucleon cross section as small as 3.9 * 10^{-33} cm^2 at 90% confidence level for sub-GeV/c^2 masses.

hep-ex

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of $^{125}$Xe and $^{127}$Xe, and double-electron-capture decays of $^{124}$Xe, are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy $\beta$ decays, and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1~keV M-shell, 5.2~keV L-shell, and 33.2~keV K-shell at drift fields of 193 and 96.5~V/cm. The LL double-electron-capture decay of $^{124}$Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

hep-ex

First constraint for atmospheric millicharged particles with the LUX-ZEPLIN experiment

We report on a search for millicharged particles (mCPs) produced in cosmic ray proton atmospheric interactions using data collected during the first science run of the LUX-ZEPLIN experiment. The mCPs produced by two processes -- meson decay and proton bremsstrahlung -- are considered in this study. This search utilized a novel signature unique to liquid xenon (LXe) time projection chambers (TPCs), allowing sensitivity to mCPs with masses ranging from 10 to 1000 MeV/c$^2$ and fractional charges between 0.001 and 0.02 of the electron charge e. With an exposure of 60 live days and a 5.5 tonne fiducial mass, we observed no significant excess over background. This represents the first experimental search for atmospheric mCPs and the first search for mCPs using an underground LXe experiment.

hep-ex

Dark Matter Search Results from 4.2 Tonne-Years of Exposure of the LUX-ZEPLIN (LZ) Experiment

We report results of a search for nuclear recoils induced by weakly interacting massive particle (WIMP) dark matter using the LUX-ZEPLIN (LZ) two-phase xenon time projection chamber. This analysis uses a total exposure of $4.2\pm0.1$ tonne-years from 280 live days of LZ operation, of which $3.3\pm0.1$ tonne-years and 220 live days are new. A technique to actively tag background electronic recoils from $^{214}$Pb $\beta$ decays is featured for the first time. Enhanced electron-ion recombination is observed in two-neutrino double electron capture decays of $^{124}$Xe, representing a noteworthy new background. After removal of artificial signal-like events injected into the data set to mitigate analyzer bias, we find no evidence for an excess over expected backgrounds. World-leading constraints are placed on spin-independent (SI) and spin-dependent WIMP-nucleon cross sections for masses $\geq$9 GeV/$c^2$. The strongest SI exclusion set is $2.2\times10^{-48}$ cm$^{2}$ at the 90% confidence level and the best SI median sensitivity achieved is $5.1\times10^{-48}$ cm$^{2}$, both for a mass of 40 GeV/$c^2$.

hep-ex

Two-neutrino double electron capture of $^{124}$Xe in the first LUX-ZEPLIN exposure

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of $^{124}$Xe through the process of two-neutrino double electron capture (2$\nu$2EC), utilizing a $1.39\,\mathrm{kg} \times \mathrm{yr}$ isotopic exposure from the first LZ science run. A half-life of $T_{1/2}^{2\nu2\mathrm{EC}} = (1.09 \pm 0.14_{\text{stat}} \pm 0.05_{\text{sys}}) \times 10^{22}\,\mathrm{yr}$ is observed with a statistical significance of $8.3\,\sigma$, in agreement with literature. First empirical measurements of the KK capture fraction relative to other K-shell modes were conducted, and demonstrate consistency with respect to recent signal models at the $1.4\,\sigma$ level.

nucl-ex

Probing the Scalar WIMP-Pion Coupling with the first LUX-ZEPLIN data

Weakly interacting massive particles (WIMPs) may interact with a virtual pion that is exchanged between nucleons. This interaction channel is important to consider in models where the spin-independent isoscalar channel is suppressed. Using data from the first science run of the LUX-ZEPLIN dark matter experiment, containing 60 live days of data in a 5.5~tonne fiducial mass of liquid xenon, we report the results on a search for WIMP-pion interactions. We observe no significant excess and set an upper limit of $1.5\times10^{-46}$~cm$^2$ at a 90\% confidence level for a WIMP mass of 33~GeV/c$^2$ for this interaction.

hep-ex

The Data Acquisition System of the LZ Dark Matter Detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

physics.ins-det

The Design, Implementation, and Performance of the LZ Calibration Systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

physics.ins-det

Constraints On Covariant WIMP-Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The first science run of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA, has reported leading limits on spin-independent WIMP-nucleon interactions and interactions described from a non-relativistic effective field theory (NREFT). Using the same 5.5~t fiducial mass and 60 live days of exposure we report on the results of a relativistic extension to the NREFT. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the WIMP which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0~keV$_\text{nr}$ to 270~keV$_\text{nr}$, we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases.

hep-ex

First Constraints on WIMP-Nucleon Effective Field Theory Couplings in an Extended Energy Region From LUX-ZEPLIN

Following the first science results of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber operating from the Sanford Underground Research Facility in Lead, South Dakota, USA, we report the initial limits on a model-independent non-relativistic effective field theory describing the complete set of possible interactions of a weakly interacting massive particle (WIMP) with a nucleon. These results utilize the same 5.5 t fiducial mass and 60 live days of exposure collected for the LZ spin-independent and spin-dependent analyses while extending the upper limit of the energy region of interest by a factor of 7.5 to 270 keVnr. No significant excess in this high energy region is observed. Using a profile-likelihood ratio analysis, we report 90% confidence level exclusion limits on the coupling of each individual non-relativistic WIMP-nucleon operator for both elastic and inelastic interactions in the isoscalar and isovector bases.

hep-ex

New constraints on ultraheavy dark matter from the LZ experiment

Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV/$c^2$ to a few TeV/$c^2$. Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a re-analysis of the first science run (SR1) of the LZ experiment, with an exposure of $0.9$ tonne$\times$year, to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 10$^{17}$ GeV/$c^2$.

hep-ex

A search for new physics in low-energy electron recoils from the first LZ exposure

The LUX-ZEPLIN (LZ) experiment is a dark matter detector centered on a dual-phase xenon time projection chamber. We report searches for new physics appearing through few-keV-scale electron recoils, using the experiment's first exposure of 60 live days and a fiducial mass of 5.5t. The data are found to be consistent with a background-only hypothesis, and limits are set on models for new physics including solar axion electron coupling, solar neutrino magnetic moment and millicharge, and electron couplings to galactic axion-like particles and hidden photons. Similar limits are set on weakly interacting massive particle (WIMP) dark matter producing signals through ionized atomic states from the Migdal effect.

hep-ex

Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment

The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-beta decay searches and effective field theory interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations of bulk and fixed radioactive backgrounds are consistent with expectations from the ex-situ assays. The observed background rate after WIMP search criteria were applied was $(6.3\pm0.5)\times10^{-5}$ events/keV$_{ee}$/kg/day in the low-energy region, approximately 60 times lower than the equivalent rate reported by the LUX experiment.

hep-ex

A backing detector for order-keV neutrons

We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$ν$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of $\sim$25\% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of $\sim$17$~μ$s. The prototype was characterized using a \ce{^{252}Cf} neutron source and agreement with the simulation was observed within a few percent level.

physics.ins-det

Characterization of Gadolinium-loaded Plastic Scintillator for Use as a Neutron Veto

Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in high-energy physics experiments. However, a liquid scintillator can leak and is not as amenable to modular or complex shapes as a solid scintillator. Polystyrene-based scintillators from a variety of gadolinium compounds with varying concentrations were polymerized in our laboratory. The light output, emission spectra, and attenuation length of our samples were measured and light collection strategies using a wavelength shifting (WLS) fiber were evaluated. The measured optical parameters were used to tune a Geant4-based optical Monte Carlo, enabling the trapping efficiency to be calculated. This technology was also evaluated as a possible neutron veto for the direct detection dark matter experiment, Super Cryogenic Dark Matter Search (SuperCDMS).

physics.ins-det

Performance of the EDELWEISS-III experiment for direct dark matter searches

We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $β$- and $α$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $α$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $γ$-ray events has been demonstrated using $γ$-calibrations with $^{133}$Ba sources leading to a value of $R_{γ{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $γ$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.

physics.ins-det

Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach

We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoils from $^{206}$Pb and neutrons as well as detector intrinsic backgrounds were modelled from data outside the region of interest and constrained in the analysis. The basic data selection and most of the background models are the same as those used in a previously published analysis based on Boosted Decision Trees (BDT). For the likelihood approach applied in the analysis presented here, a larger signal efficiency and a subtraction of the expected background lead to a higher sensitivity, especially for the lowest WIMP masses probed. No statistically significant signal was found and upper limits on the spin-independent WIMP-nucleon scattering cross section can be set with a hypothesis test based on the profile likelihood test statistics. The 90% C.L. exclusion limit set for WIMPs with $m_χ= 4\,\mathrm{GeV/}c^2$ is $1.6 \times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven with respect to the BDT-based analysis. For WIMP masses above $15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in good agreement.

astro-ph.CO

Measurement of the cosmogenic activation of germanium detectors in EDELWEISS-III

We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for $^{65}$Zn. These results are the most accurate for these isotopes. A lower limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also presented. They are compared to model predictions present in literature and to estimates calculated with the ACTIVIA code.

astro-ph.CO