SearcharxivSearch

arXiv subjects

G. Iakovidis

Publications and source records attributed to G. Iakovidis.

8 recordsLinked to original sources

Detector R&D needs for the next generation $e^+e^-$ collider

The 2021 Snowmass Energy Frontier panel wrote in its final report "The realization of a Higgs factory will require an immediate, vigorous and targeted detector R&D program". Both linear and circular $e^+e^-$ collider efforts have developed a conceptual design for their detectors and are aggressively pursuing a path to formalize these detector concepts. The U.S. has world-class expertise in particle detectors, and is eager to play a leading role in the next generation $e^+e^-$ collider, currently slated to become operational in the 2040s. It is urgent that the U.S. organize its efforts to provide leadership and make significant contributions in detector R&D. These investments are necessary to build and retain the U.S. expertise in detector R&D and future projects, enable significant contributions during the construction phase and maintain its leadership in the Energy Frontier regardless of the choice of the collider project. In this document, we discuss areas where the U.S. can and must play a leading role in the conceptual design and R&D for detectors for $e^+e^-$ colliders.

hep-ex

The New Small Wheel electronics

The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the "small" Thin Gap Chambers, with a total of 2.45 Million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm$^{2}$ at the expected HL-LHC luminosity of $\mathcal{L}$=7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.

hep-ex

Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System

The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6 Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability rom an application point-of-view.

physics.ins-det

Construction techniques and performances of a full-size prototype Micromegas chamber for the ATLAS muon spectrometer upgrade

A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in constructing the single modules of the chamber in various INFN laboratories and the final assembly at the Laboratori Nazionali di Frascati (LNF). Results of the chamber exposure to the CERN SPS/H8 beam line in June 2016 are also presented. The performances achieved in the construction and the results of the test beam are compared with the requirements, which are imposed by the severe environment during the data-taking of the LHC foreseen for the next years.

physics.ins-det

Identification of circles from datapoints using Gaussian sums

We present a pattern recognition method which use datapoints on a plane and estimates the parameters of a circle. MC data are generated in order to test the method's efficiency over noise hits, uncertainty in the hits positions and number of datapoints. The scenario were the hits from a quadrant of the circle are missing is also considered. The method proposed is proven to be robust, accurate and very efficient.

physics.ins-det

Examining the Geometric Mean Method for the Extraction of Spatial Resolution

The spatial resolution of a detector, using a reference detector telecscope, can be measured applying the geometric mean method, with tracks reconstructed from hits of all the detectors, including ($σ_\mathrm{in}$) and excluding ($σ_\mathrm{ex}$) the hit from the detector under study. The geometric mean of the two measured resolution values ($σ=\sqrt{σ_\mathrm{ex}σ_\mathrm{in}}$), is proposed to provide a more accurate estimate of the intrinsic detector resolution. This method has been tested using a Monte Carlo algorithm and is proven to give accurate results, independently of the distance between the detectors used for the track fitting. The method does not give meaningful results if all the detectors do not carry the same characteristics.

physics.ins-det

Ageing studies of resistive Micromegas detectors for the HL-LHC

Resistive-anode Micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working in high flux and high radiations environment like in the HL-LHC (ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiations (X-rays, cold neutrons, 60 Co gammas) up to an equivalent HL-LHC time of more than five years without showing any degradation of the performances in terms of gain and energy resolution. Beam test studies took place in October 2012 to assess the tracking performances (efficiency, spatial resolution,...). Results of ageing studies and beam test performances are reported in this paper.

physics.ins-det

An ageing study of resistive micromegas for the HL-LHC environment

Resistive-anode micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working at high flux and high ionizing radiation like in the HL-LHC (up to ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiation (X-rays, cold neutrons, $^{60}$Co gammas and alphas) above the equivalent charge produced at the detector in five HL-LHC running years without showing any degradation of the performances in terms of gain and energy resolution. This study has been completed with the characterization of the tracking performances in terms of efficiency and spatial resolution, verifying the compatibility of results obtained with both resistive micromegas detectors, irradiated and non-irradiated one.

physics.ins-det