Searcharxiv⌕ Search

arXiv subjects

G. K. Giovanetti

Publications and source records attributed to G. K. Giovanetti.

At least 19 recordsLinked to original sources

Search for two-neutrino double electron capture in $^{36}$Ar with the DarkSide-50 detector

Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shells and two neutrinos are emitted. We report on the first search for two-neutrino double electron capture in the $\textit{KK}$- and $\textit{KL}$-shells of $^{36}$Ar using the low-radioactivity liquid argon target from underground sources in the DarkSide-50 experiment. No statistically significant excess was observed with approximately 12 ton-day exposure of underground argon (UAr) and, taking into account the $^{36}$Ar isotopic abundance in UAr (0.007%), we set a limit on the half-life of the two-electron capture process in $^{36}$Ar of $T_{1/2} > 9.2 \times 10^{19}$ yr at 90% C.L. The sensitivity of the DarkSide-20k experiment, which will become operational in the next few years, was also evaluated and is expected to increase by a factor $\sim$100 with 10 years of expected operation and assuming the same $^{36}$Ar abundance as in the DarkSide-50 underground argon target.

nucl-ex↗

First Nuclear Ultra-Heavy Dark Matter Search in Argon Time Projection Chambers with the DarkSide-50 Experiment

We report the first search for nuclear ultra-heavy dark matter (UHDM) in a dual-phase liquid argon time projection chamber using the DarkSide-50 experiment. Unlike conventional weakly interacting massive particles (WIMPs), nuclear UHDM candidates may be composed of many dark nucleons and scatter numerous times while passing through the detector. Accounting for energy loss through the Earth's overburden, we apply selection criteria optimized for multi-scatter event topologies using the 532-day low-radiation campaign of the DarkSide-50 detector. Excluded limits on the UHDM-nucleon scattering cross section for dark nucleon masses of $m_χ= 10, 50, 100, 500 \, \mathrm{GeV/c^2}$ are presented.

hep-ex↗

Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide programme

Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass WIMP interactions, setting new world-leading constraints in the 1-3 GeV/c^2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.

hep-ex↗

Fermionic sub-GeV Dark Matter from evaporating Primordial Black Holes at DarkSide-50

We present a search for boosted dark matter from Primordial Black Holes (PBH) evaporation using the DarkSide-50 ionization-signal-only dataset corresponding to the experiment's ($12202\pm180$) ${\rm kg\: d}$ exposure. We focus on evaporation of PBHs with masses in the range [$10^{14},\,10^{16}$] g producing Dirac fermionic dark matter particles with sub-GeV kinetic energy. These relativistic particles, with energies up to hundreds of MeV, can generate detectable signals for masses below $\mathcal{O}(100)$ MeV. The absence of a signal enables setting complementary limits to those derived from cosmological observations and direct detection searches for cosmic ray-boosted dark matter.

hep-ph↗

Rare multi-nucleon decays with the full data sets of the Majorana Demonstrator

The Majorana Demonstrator was an ultra-low-background experiment designed for neutrinoless double-beta decay ($0νββ$) investigation in $^{76}$Ge. Located at the Sanford Underground Research Facility in Lead, South Dakota, the Demonstrator utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to $\sim 88\%$ in $^{76}$Ge), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of $1.83\times10^{26}$ years (90\% confidence level) for $^{76}$Ge($ppp$) $\rightarrow$ $^{73}$Cu e$^+π^+π^+$ and $^{76}$Ge($ppn$) $\rightarrow$ $^{73}$Zn e$^+π^+$. The partial lifetime limit for the fully inclusive tri-proton decay mode of $^{76}$Ge is found to be $2.1\times10^{25}$ yr. Furthermore, we have updated limits for corresponding multi-nucleon decays.

nucl-ex↗

Final Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se

$^{76}$Ge can $ββ$ decay into three possible excited states of $^{76}$Se, with the emission of two or, if the neutrino is Majorana, zero neutrinos. None of these six transitions have yet been observed. The MAJORANA DEMONSTRATOR was designed to study $ββ$ decay of $^{76}$Ge using a low background array of high purity germanium detectors. With 98.2 kg-y of isotopic exposure, the DEMONSTRATOR sets the strongest half-life limits to date for all six transition modes. For $2νββ$ to the $0^+_1$ state of $^{76}$Se, this search has begun to probe for the first time half-life values predicted using modern many-body nuclear theory techniques, setting a limit of $T_{1/2}>1.5\times10^{24}$ y (90% CL).

nucl-ex↗

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

hep-ex↗

Production, Quality Assurance and Quality Control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m^2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. 16 Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the quality assurance and quality control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision flip-chip bonding, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

physics.ins-det↗

Impact of extreme ultraviolet radiation on the scintillation of pure and xenon-doped liquid argon

The Xenon-Argon Technology (X-ArT) collaboration presents a study on the dynamics of pure and xenon-doped liquid argon (LAr) scintillation. Using two types of silicon photomultipliers sensitive to different wavelength ranges, we provide evidence in favor of a contribution from long-lived (>10 $μ$s) extreme ultraviolet (EUV) lines emitted from argon atomic states, which enhances the light yield. This component is present in both pure and xenon-doped LAr, becoming more pronounced at higher xenon concentrations, where it complements the traditional collisional energy transfer process. To explain this mechanism, we develop a comprehensive model of the Xe-doped LAr scintillation process that integrates both collisional and radiative contributions. Additionally, we investigate how xenon doping affects LAr scintillation light yield and pulse shape discrimination. Finally, we hypothesize that the EUV component may explain the emission of spurious electrons, a known challenge in light dark matter searches using noble liquids. By characterizing the scintillation dynamics in Xe-doped LAr, identifying the long-lived EUV component, and exploring the potential origin of spurious electrons, this work lays the groundwork for optimizing detector performance and advancing the design and sensitivity of future noble liquid particle detectors.

hep-ex↗

Quality Assurance and Quality Control of the $26~\text{m}^2$ SiPM production for the DarkSide-20k dark matter experiment

DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with \SI{50} {tonnes} of low radioactivity underground argon (UAr) acting as the WIMP target. NUV-HD-cryo Silicon Photomultipliers (SiPM)s designed by Fondazione Bruno Kessler (FBK) (Trento, Italy) were selected as the photon sensors covering two $10.5~\text{m}^2$ Optical Planes, one at each end of the TPC, and a total of $5~\text{m}^2$ photosensitive surface for the liquid argon veto detectors. This paper describes the Quality Assurance and Quality Control (QA/QC) plan and procedures accompanying the production of FBK~NUV-HD-cryo SiPM wafers manufactured by LFoundry s.r.l. (Avezzano, AQ, Italy). SiPM characteristics are measured at 77~K at the wafer level with a custom-designed probe station. As of March~2025, 1314 of the 1400 production wafers (94% of the total) for DarkSide-20k were tested. The wafer yield is $93.2\pm2.5$\%, which exceeds the 80\% specification defined in the original DarkSide-20k production plan.

physics.ins-det↗

Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator

Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the \MJD\ experiment. Using a 37.5 kg-yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the $e \rightarrow ν_e \overline{ν_e} ν_e$ decay channel by more than an order of magnitude. We also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.

nucl-ex↗

The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance

Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($ββ(0ν)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations. It covers the electroforming, underground infrastructure, enrichment, detector fabrication, low-background and construction techniques, electronics, data acquisition, databases, and data processing of the MAJORANA DEMONSTRATOR. Method: The MAJORANA DEMONSTRATOR operated inside an ultra-low radioactivity passive shield at the 4850-foot~level of the Sanford Underground Research Facility (SURF) from 2015-2021. Results and Conclusions: The MAJORANA DEMONSTRATOR achieved the best energy resolution and second-best background level of any $ββ(0ν)$ search. This enabled it to achieve an ultimate half-life limit on $ββ(0ν)$ in $^{76}\mathrm{Ge}$ of $8.3\times 10^{25}$~yr (90\% C.L.) and perform a rich set of searches for other physics beyond the Standard Model.

physics.ins-det↗

Search for dark matter annual modulation with DarkSide-50

Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above $40~{\rm eV_{ee}}$, the lowest threshold ever achieved in such a search.

hep-ex↗

Interpretable Boosted Decision Tree Analysis for the Majorana Demonstrator

The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.

physics.data-an↗

An assay-based background projection for the MAJORANA DEMONSTRATOR using Monte Carlo Uncertainty Propagation

The background index is an important quantity which is used in projecting and calculating the half-life sensitivity of neutrinoless double-beta decay ($0νββ$) experiments. A novel analysis framework is presented to calculate the background index using the specific activities, masses and simulated efficiencies of an experiment's components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a background index distribution from the specific activity, mass and efficiency distributions. This analysis method is applied to the MAJORANA DEMONSTRATOR, which deployed arrays of high-purity Ge detectors enriched in $^{76}$Ge to search for $0νββ$. The framework projects a mean background index of $\left[8.95 \pm 0.36\right] \times 10^{-4}$cts/(keV kg yr) from $^{232}$Th and $^{238}$U in the DEMONSTRATOR's components.

nucl-ex↗

Exotic dark matter search with the Majorana Demonstrator

With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report new limits on fermionic dark matter absorption ($χ+ A \rightarrow ν+ A$) and sub-GeV DM-nucleus 3$\rightarrow$2 scattering ($χ+ χ+ A \rightarrow ϕ+ A$), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1--100)-keV low energy region of a 37.5-kg y exposure collected by the Demonstrator between May 2016 and November 2019, using a set of $^{76}$Ge-enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation.

hep-ex↗

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

hep-ex↗

Majorana Demonstrator Data Release for AI/ML Applications

The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificial Intelligence (AI) and Machine Learning (ML) algorithms upon our data. This document is structured as follows. Section I provides an overview of the dataset's content and format; Section II outlines the location of this dataset and the method for accessing it; Section III presents the NPML Machine Learning Challenge associated with this dataset; Section IV contains a disclaimer from the Majorana collaboration regarding the use of this dataset; Appendix A contains technical details of this data release. Please direct questions about the material provided within this release to liaobo77@ucsd.edu (A. Li).

cs.LG↗