SearcharxivSearch

arXiv subjects

G. L. Jones

Publications and source records attributed to G. L. Jones.

14 recordsLinked to original sources

Recoil-Order and Radiative Corrections to the aCORN Experiment

The aCORN experiment measures the electron-antineutrino $a$-coefficient in free neutron decay. We update the previous aCORN results to include radiative and recoil corrections to first order, and discuss a key issue in the comparison of results from different $a$-coefficient experimental methods when these effects are considered. The corrected combined result is $\overline{a} = -0.10779 \pm 0.00125\, ({\rm stat}) \pm 0.00133\, ({\rm sys})$, averaged over the full Fermi neutron beta spectrum. The corresponding corrected result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2712 \pm 0.0061$. This improves agreement with previous $a$-coefficient experiments, in particular the 2020 aSPECT result

nucl-ex

Measurement of the neutron decay electron-antineutrino angular correlation by the aCORN experiment

The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on the new NG-C neutron guide end position: $a = -0.10758 \pm 0.00136 (\mbox{stat}) \pm 0.00148 (\mbox{sys})$. This is consistent within uncertainties with the result from the first aCORN run on the NG-6 cold neutron beam. Combining the two aCORN runs we obtain $a = -0.10782 \pm 0.00124 (\mbox{stat}) \pm 0.00133 (\mbox{sys})$, which has an overall relative standard uncertainty of 1.7 \%. The corresponding result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2796\pm 0.0062$.

nucl-ex

Neutron Polarimetry Using a Polarized 3He Cell for the aCORN Experiment

The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The dependence of the neutron transmission on the spin filter direction was used to calculate the neutron polarization. The time dependent transmission was fit to a model which included the neutron spectrum, and 3He polarization losses from spin relaxation and AFP-NMR. The polarization of the NG-C beamline was found to be ${\mid}P_\mathrm{n}{\mid} \leq 4\times 10^{-4}$ with 90 % confidence.

physics.ins-det

Measurement of the electron-antineutrino correlation in neutron beta decay: aCORN experiment

The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertainty of 3.8%. The second run on the new NG-C high flux beam line promises an improvement in precision to <2%.

nucl-ex

aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay

We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.

physics.ins-det

The aCORN Backscatter-Suppressed Beta Spectrometer

Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.

physics.ins-det

Determination of the Free Neutron Lifetime

We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve both.

nucl-ex

Search for a T-odd, P-even Triple Correlation in Neutron Decay

Background: Time-reversal-invariance violation, or equivalently CP violation, may explain the observed cosmological baryon asymmetry as well as signal physics beyond the Standard Model. In the decay of polarized neutrons, the triple correlation D \cdot(p_{e}\timesp_ν) is a parity-even, time-reversal- odd observable that is uniquely sensitive to the relative phase of the axial-vector amplitude with respect to the vector amplitude. The triple correlation is also sensitive to possible contributions from scalar and tensor amplitudes. Final-state effects also contribute to D at the level of 1e-5 and can be calculated with a precision of 1% or better. Purpose: We have improved the sensitivity to T-odd, P-even interactions in nuclear beta decay. Methods: We measured proton-electron coincidences from decays of longitudinally polarized neutrons with a highly symmetric detector array designed to cancel the time-reversal-even, parity-odd Standard-Model contributions to polarized neutron decay. Over 300 million proton-electron coincidence events were used to extract D and study systematic effects in a blind analysis. Results: We find D = [-0.94\pm1.89(stat)\pm0.97(sys)]e-4. Conclusions: This is the most sensitive measurement of D in nuclear beta decay. Our result can be interpreted as a measurement of the phase of the ratio of the axial-vector and vector coupling constants (CA/CV= |λ|exp(iϕ_AV)) with ϕ_AV = 180.012° \pm0.028° (68% confidence level) or to constrain time-reversal violating scalar and tensor interactions that arise in certain extensions to the Standard Model such as leptoquarks. This paper presents details of the experiment, analysis, and systematic- error corrections.

nucl-ex

A New Limit on Time-Reversal Violation in Beta Decay

We report the results of an improved determination of the triple correlation $D P \cdot(p_{e}\times p_ν)$ that can be used to limit possible time-reversal invariance in the beta decay of polarized neutrons and constrain extensions to the Standard Model. Our result is $D=(-0.96\pm 1.89 (stat)\pm 1.01 (sys))\times 10^{-4}$. The corresponding phase between g_A and g_V is $ϕ_{AV} = 180.013^\circ\pm0.028^\circ$ (68 % confidence level). This result represents the most sensitive measurement of D in beta decay.

nucl-ex

High-Efficiency Resonant RF Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams

We have developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to RF neutron spin flippers based on adiabatic fast passage. The spin rotator does not change the kinetic energy of the neutrons and leaves the neutron beam phase space unchanged to high precision. We discuss the design of the spin rotator and describe two types of transmission-based neutron spin-flip efficiency measurements where the neutron beam was both polarized and analyzed by optically-polarized 3He neutron spin filters. The efficiency of the spin rotator was measured to be 98.0+/-0.8% on resonance for neutron energies from 3.3 to 18.4 meV over the full phase space of the beam. As an example of the application of this device to an experiment we describe the integration of the RF spin rotator into an apparatus to search for the small parity-violating asymmetry A_gamma in polarized cold neutron capture on para-hydrogen by the NPDGamma collaboration at LANSCE.

nucl-ex

Upper Bounds on Parity Violating Gamma-Ray Asymmetries in Compound Nuclei from Polarized Cold Neutron Capture

Parity-odd asymmetries in the electromagnetic decays of compound nuclei can sometimes be amplified above values expected from simple dimensional estimates by the complexity of compound nuclear states. In this work we use a statistical approach to estimate the root mean square (RMS) of the distribution of expected parity-odd correlations $\vec{s_{n}} \cdot \vec{k_γ}$, where $\vec {s_{n}}$ is the neutron spin and $\vec{k_γ}$ is the momentum of the gamma, in the integrated gamma spectrum from the capture of cold polarized neutrons on Al, Cu, and In and we present measurements of the asymmetries in these and other nuclei. Based on our calculations, large enhancements of asymmetries were not predicted for the studied nuclei and the statistical estimates are consistent with our measured upper bounds on the asymmetries.

nucl-ex

emiT: an apparatus to test time reversal invariance in polarized neutron decay

We describe an apparatus used to measure the triple-correlation term (\D \hatσ_n\cdot p_e\times p_ν) in the beta-decay of polarized neutrons. The \D-coefficient is sensitive to possible violations of time reversal invariance. The detector has an octagonal symmetry that optimizes electron-proton coincidence rates and reduces systematic effects. A beam of longitudinally polarized cold neutrons passes through the detector chamber, where a small fraction beta-decay. The final-state protons are accelerated and focused onto arrays of cooled semiconductor diodes, while the coincident electrons are detected using panels of plastic scintillator. Details regarding the design and performance of the proton detectors, beta detectors and the electronics used in the data collection system are presented. The neutron beam characteristics, the spin-transport magnetic fields, and polarization measurements are also described.

nucl-ex

A measurement of parity-violating gamma-ray asymmetries in polarized cold neutron capture on 35Cl, 113Cd, and 139La

An apparatus for measuring parity-violating asymmetries in gamma-ray emission following polarized cold neutron capture was constructed as a 1/10th scale test of the design for the forthcoming n+p->d+gamma experiment at LANSCE. The elements of the polarized neutron beam, including a polarized 3He neutron spin filter and a radio frequency neutron spin rotator, are described. Using CsI(Tl) detectors and photodiode current mode readout, measurements were made of asymmetries in gamma-ray emission following neutron capture on 35Cl, 113Cd, and 139La targets. Upper limits on the parity-allowed asymmetry $s_n \cdot (k_γ \times k_n)$ were set at the level of 7 x 10^-6 for all three targets. Parity-violating asymmetries $s_n \cdot k_γ$ were observed in 35Cl, A_gamma = (-29.1 +- 6.7) x 10^-6, and 139La, A_gamma = (-15.5 +- 7.1) x 10^-6, values consistent with previous measurements.

nucl-ex

New Limit on the D Coefficient in Polarized Neutron Decay

We describe an experiment that has set new limits on the time reversal invariance violating D coefficient in neutron beta-decay. The emiT experiment measured the angular correlation J . p_e x p_p using an octagonal symmetry that optimizes electron-proton coincidence rates. The result is D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the phase of g_A/g_V and limits contributions to T violation due to leptoquarks. This paper presents details of the experiment, data analysis, and the investigation of systematic effects.

nucl-ex