Searcharxiv⌕ Search

arXiv subjects

G. Luzón

Publications and source records attributed to G. Luzón.

At least 19 recordsLinked to original sources

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8$\times$8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 $μ$m per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

physics.ins-det↗

Low-energy threshold demonstration for dark matter searches in TREX-DM with an $^{37}$Ar source produced at CNA HiSPANoS

We report on the successful implementation of an $^{37}$Ar calibration source in the TREX-DM detector, a high-pressure time projection chamber designed for low-mass dark matter searches. The $^{37}$Ar source was produced through fast neutron activation of CaO powder at the HiSPANoS facility of Centro Nacional de Aceleradores (CNA) in Spain, yielding $O(1)$ kBq of activity. Using a novel combined GEM-Micromegas readout system, we successfully detected both characteristic emissions from $^{37}$Ar decay (2.82 keV and 270 eV) and achieved unprecedented energy threshold performance in TREX-DM, approaching the single-electron ionization energy of argon.

physics.ins-det↗

Spatial resolution studies with the BabyIAXO Micromegas prototype

The spatial resolution of the Micromegas prototype developed for the BabyIAXO experiment was evaluated using a low-energy X-ray beam at the SOLEIL synchrotron facility. BabyIAXO, currently under construction, aims to search for hypothetical solar axions. A key component of the experiment is a low-background X-ray detector with high efficiency in the 1-10 keV energy range and stringent background rejection capabilities. Achieving a spatial resolution on the order of, or better than, 1 mm is critical for accurately reconstructing signal shapes and positions, and for effectively discriminating between signal and background events. Therefore, a precise characterization of the detector's spatial resolution is essential to validate its suitability for the experiment. This study involved scanning the IAXO-D1 Micromegas detector under various beam energies, positions, and drift field configurations to evaluate their influence on spatial resolution. A resolution of approximately 100 $μ$m at 6 keV was achieved, confirming the strong potential of this technology for application in the final BabyIAXO setup.

physics.ins-det↗

Search for solar axions produced through the axion-electron coupling $g_{ae}$ using a new GridPix detector at CAST

We present a search for solar axions produced through the axion-electron coupling $(g_{ae})$ using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017-2018. Using machine learning techniques and the veto systems, we achieved a background rate of $1.06\times 10^{-5}\,\text{keV}^{-1}\text{cm}^{-2}\text{s}^{-1}$ at a signal efficiency of about $80\,\%$ in the $0.2$-$8\,\text{keV}$ range. Analysis of the data yielded no significant excess above background, allowing us to set a new upper limit on the product of the axion-electron and axion-photon couplings of $g_{ae}\cdot g_{aγ} < 7.35\times 10^{-23}\,\text{GeV}^{-1}$ at $95\,\%$ confidence level. This result improves upon the previous best helioscope limit and demonstrates the potential of GridPix technology for rare event searches. Additionally, we derived a limit on the axion-photon coupling of $g_{aγ} < 9.0\times 10^{-11}\,\text{GeV}^{-1}$ at $95\,\%$ CL, which, while not surpassing CAST's best limit, provides complementary constraints on axion models.

hep-ex↗

Review of Neutron Yield from ($α$, n) Reactions: Data, Methods, and Prospects

Understanding the radiogenic neutron production rate through the ($α$, n) reaction is crucial in many areas of physics, including dark matter searches, neutrino studies, and nuclear astrophysics. In addition to its relevance for fundamental research, the ($α$, n) reaction also plays a significant role in nuclear energy technologies, for example by contributing to neutron production in subcritical systems using UO$_{2}$, as well as in applications such as medical physics. This review examines the current state of ($α$, n) yield calculations and neutron spectra, describes the computational tools used for their estimation, and discusses the available cross-section data. We explore the uncertainties affecting ($α$, n) yield estimations and propose a strategy to enhance their accuracy. Furthermore, this paper discusses and emphasizes the need for new measurements of ($α$, n) cross-sections for a variety of relevant materials. Such measurements are essential for improving neutron flux predictions, which are crucial for reducing uncertainties in sensitivity estimates for next-generation physics experiments operating in the keV--MeV range.

nucl-ex↗

Micromegas with GEM preamplification for enhanced energy threshold in low-background gaseous time projection chambers

Background: we develop the concept of a Micromegas (MICRO-MEsh GAseous Structure) readout plane with an additional GEM (Gas Electron Multiplier) preamplification stage placed a few mm above it, to increase the maximum effective gain of the combined readout. We implement it and test it in realistic conditions for its application to low-background dark matter searches like the TREX-DM experiment. Methods: for this, we use a Micromegas of microbulk type, built with radiopure materials. A small test chamber allowing for systematic scanning of voltages and pressures is used. In addition, a TREX-DM full-scale set-up has also been built and tested, featuring a replica of the fully-patterned TREX-DM microbulk readout. Results: we report on GEM effective extra gain factors of about 90, 50 and 20 in 1, 4 and 10 bar of Ar-1%iC$_{4}$H$_{10}$. Conclusions: the results here obtained show promise to lower the threshold of the experiment down to 50 eV$_{ee}$, corresponding to substantially enhanced sensitivity to low-mass WIMPs (Weakly Interacting Massive Particles).

physics.ins-det↗

COCOA: a compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

astro-ph.IM↗

Daily modulations and broadband strategy in axion searches. An application with CAST-CAPP detector

It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities $Ω_{\rm dark}\sim Ω_{\rm visible}$. In this framework, the population of galactic axions with mass $ 10^{-6} {\rm eV}\lesssim m_a\lesssim 10^{-3}{\rm eV}$ and velocity $\langle v_a\rangle\sim 10^{-3} c$ will be accompanied by axions with typical velocities $\langle v_a\rangle\sim 0.6 c$ emitted by AQNs. Furthermore, in this framework, it has also been argued that the AQN-induced axion daily modulation (in contrast with the conventional WIMP paradigm) could be as large as $(10-20)\%$, which represents the main motivation for the present investigation. We argue that the daily modulations along with the broadband detection strategy can be very useful tools for the discovery of such relativistic axions. The data from the CAST-CAPP detector have been used following such arguments. Unfortunately, due to the dependence of the amplifier chain on temperature-dependent gain drifts and other factors, we could not conclusively show the presence or absence of a dark sector-originated daily modulation. However, this proof of principle analysis procedure can serve as a reference for future studies.

hep-ex↗

The Stochastic Light Confinement of LiquidO

Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechanisms that are then propagated through transparent media to photosensors placed typically on the detector's periphery, sometimes up to tens of metres away. LiquidO is a new technique pioneering the use of opaque media to stochastically confine light around each energy deposition while collecting it with an array of fibres that thread the medium. This approach preserves topological event information otherwise lost in the conventional approach, enabling real-time imaging down to the MeV scale. Our article demonstrates LiquidO's imaging principle with a ten-litre prototype, revealing successful light confinement of 90% of the detected light within a 5 cm radius sphere, using a custom opaque scintillator with a scattering length on the order of a few millimetres. These high-resolution imaging capabilities unlock opportunities in fundamental physics research and applications beyond. The absolute amount of light detected is also studied, including possible data-driven extrapolations to LiquidO-based detectors beyond prototyping limitations. Additionally, LiquidO's timing capabilities are explored through its ability to distinguish Cherenkov light from a slow scintillator.

physics.ins-det↗

A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector

Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the previous exposure time. The detector was operated with a xenon-based gas mixture for part of the new run, providing technical insights for future detector configurations in IAXO. No counts are detected in the 95% signal-encircling region during the new run, while 0.75 are expected. The new data improve the axion-photon coupling limit to 5.8$\times 10^{-11}\,$GeV$^{-1}$ at 95% C.L. (for $m_a \lesssim 0.02$ eV), the most restrictive experimental limit to date.

hep-ex↗

Background discrimination with a Micromegas detector prototype and veto system for BabyIAXO

In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The goal of the measurement was to study techniques for background discrimination. In addition to common techniques we used a multi-layer veto system designed to tag cosmogenic neutron background. Over an effective time of 52 days, a background level of $8.6 \times 10^{-7}\,\text{counts keV}^{-1}\,\text{cm}^{-2} \, \text{s}^{-1}$ was reached in a laboratory at above ground level. This is the lowest background level achieved at surface level. In this paper we present the experimental setup, show simulations of the neutron-induced background, and demonstrate the process to identify background signals in the data. Finally, prospects to reach lower background levels down to $10^{-7} \, \text{counts keV}^{-1} \, \text{cm}^{-2} \, \text{s}^{-1}$ will be discussed.

physics.ins-det↗

Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos

The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity dominated by potassium (40K) and the decay chains of uranium (238U) and thorium (232Th). This radiogenic energy output is critical to planetary dynamics and must be accurately measured for a complete understanding of the overall heat budget and thermal history of the Earth. Detecting geoneutrinos remains the only direct probe to do so and constitutes a challenging objective in modern neutrino physics. In particular, the intriguing potassium geoneutrinos have never been observed and thus far have been considered impractical to measure. We propose here a novel approach for potassium geoneutrino detection using the unique antimatter signature of antineutrinos to reduce the otherwise overwhelming backgrounds to observing this rarest signal. The proposed detection framework relies on the innovative LiquidO detection technique to enable positron (e+) identification and antineutrino interactions with ideal isotope targets identified here for the first time. We also provide the complete experimental methodology to yield the first potassium geoneutrino discovery.

physics.geo-ph↗

Ultra low background Micromegas detectors for BabyIAXO solar axion search

The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potential for discovery. One of the crucial components of the project is the ultra-low background X-ray detectors that will image the X-ray photons produced by axion conversion in the experiment. The baseline detection technology for this purpose are Micromegas (Microbulk) detectors. We will show the quest and the strategy to attain the very challenging levels of background targeted for BabyIAXO that need a multi-approach strategy coming from ground measurements, screening campaigns of components of the detector, underground measurements, background models, in-situ background measurements as well as powerful rejection algorithms. First results from the commissioning of the BabyIAXO prototype will be shown.

hep-ex↗

Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors

Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potential source of background. Several purifiers are studied for their O 2 and H 2 O purification efficiency and Rn emanation rates, aiming to identify the lowest-Rn options. Furthermore, the absorption of quenchers by the purifiers is assessed when used in a recirculating closed-loop gas system.

physics.ins-det↗

Search for Dark Matter Axions with CAST-CAPP

The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to $g_{aγγ} = 8 \times {10^{-14}}$ $GeV^{-1}$ at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.

hep-ex↗

Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

physics.ins-det↗

Microbulk Micromegas in non-flammable mixtures of argon and neon at high pressure

We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of drift and amplification voltages and pressures from 1 bar to 10 bar for argon and from 5 bar to 10 bar in neon, in steps of 1 bar. Maximum gains higher than 1.7e3 (1.7e4) in argon (neon) are measured for all pressures, remarkably without the significant decrease with pressure typically observed in other amplification structures. A competitive energy resolution at 22.1 keV, but with a slight degradation with pressure, is observed:from 10.8% at 1 bar to 15.6% FWHM at 10 bar in argon and from 8.3% at 5 bar to 15.0% FWHM at1 10 bar in neon. The experimental setup, procedure and the results will be presented and discussed in detail. The work is motivated by the TREX-DM experiment, that is operating in the Laboratorio Subterráneo de Canfranc with the mentioned mixtures, although the results may be of interest for other applications of time projection chambers at high pressures.

physics.ins-det↗

First results of the CAST-RADES haloscope search for axions at 34.67 $μ$eV

We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$μ$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g$_{aγ}\gtrsim 4\times10^{-13} \text{GeV}^{-1}$ over a mass range of 34.6738 $μ$eV < $m_a$ < 34.6771 $μ$eV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 $μ$eV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.

hep-ex↗