Searcharxiv⌕ Search

arXiv subjects

G. Maccarrone

Publications and source records attributed to G. Maccarrone.

36 records · Page 2Linked to original sources

Search for galactic axions with a high-Q dielectric cavity

A haloscope of the QUAX--$aγ$ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to $\sim 4.5$~K is operated to search for galactic axion with mass $m_a\simeq42.8~μ\text{eV}$. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q $\sim 300000$ during the measurements in presence of magnetic field. Through the cavity tuning mechanism it was possible to modulate the resonance frequency of the haloscope in the region $10.35337-10.35345$~GHz and thus acquire different dataset at different resonance frequencies. Acquiring each dataset for about 50 minutes, combining them and correcting for the axion's signal estimation-efficiency we set a limit on the axion-photon coupling $g_{aγγ}< 0.731\times10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.

hep-ex↗

Ultra low noise readout with travelling wave parametric amplifiers: the DARTWARS project

The DARTWARS project has the goal of developing high-performing innovative travelling wave parametric amplifiers with high gain, large bandwidth, high saturation power, and nearly quantum-limited noise. The target frequency region for its applications is 5 - 10 GHz, with an expected noise temperature of about 600 mK. The development follows two different approaches, one based on Josephson junctions and one based on kinetic inductance of superconductors. This contribution mainly focuses on the Josephson travelling wave parametric amplifier, presenting its design, preliminary measurements and the test of homogeneity of arrays of Josephson junctions.

quant-ph↗

Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

physics.ins-det↗

A high-Q microwave dielectric resonator for axion dark matter haloscopes

The frequency band 1-15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high quality factor cavities that tolerate multi-Tesla fields plays a central role. We report a 3D resonator based on a right circular copper cavity with hollow cylinders that confine higher order modes around the cylinder axis. Its effective volume at 10.3\,GHz is $3.4 \cdot 10^{-2}$ liters, and under an 8\,T-field we measured an internal quality factor of more than 9 millions. These parameters demonstrate the potential of this unique resonator to probe galactic dark matter axion at remarkable scan rates of 15\,MHz/day when the cavity is readout by a quantum-limited receiver.

physics.ins-det↗

Bimodal Approach for Noise Figures of Merit Evaluation in Quantum-Limited Josephson Traveling Wave Parametric Amplifiers

The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplification and noise generation for key case study input states (Fock and coherents). Furthermore, we present an analysis of the output signals generated by the parametric amplification mechanism when thermal noise fluctuations feed the device.

cond-mat.supr-con↗

Detector Array Readout with Traveling Wave Amplifiers

Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter detectors, resonant axion-detectors, and qubits, is currently limited by the noise temperature and bandwidth of the cryogenic amplifiers. The DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project has the goal of developing high-performing innovative traveling wave parametric amplifiers (TWPAs) with a high gain, a high saturation power, and a quantum-limited or nearly quantum-limited noise. The practical development follows two different promising approaches, one based on the Josephson junctions and the other one based on the kinetic inductance of a high-resistivity superconductor. In this contribution we present the aims of the project, the adopted design solutions and preliminary results from simulations and measurements.

cond-mat.supr-con↗

Search for invisible axion dark matter of mass m$_a=43~μ$eV with the QUAX--$aγ$ experiment

A haloscope of the QUAX--$aγ$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~μ\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With the data collected in about 1 h at the cavity frequency $ν_c=10.40176$ GHz, the experiment reaches the sensitivity necessary for the detection of galactic QCD-axion, setting the $90\%$ confidence level limit to the axion-photon coupling $g_{aγγ}<0.639\times10^{-13}$ GeV$^{-1}$.

hep-ex↗

Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches

The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding to a gain of one order of magnitude with respect to a traditional copper cylindrical-cavity with the corresponding TM$_{010}$ mode resonating at the same frequency. The implications to dark-matter axion-searches with cavity experiments are discussed showing that the gain in quality factor is not spoiled by a reduced geometrical coupling $C_{030}$ of the cavity mode to the axion field. This reduction effect is estimated to be at most 20%. Numerical simulations show that frequency tuning of several hundreds MHz is feasible.

physics.ins-det↗

A density-based clustering algorithm for the CYGNO data analysis

Time Projection Chambers (TPCs) working in combination with Gas Electron Multipliers (GEMs) produce a very sensitive detector capable of observing low energy events. This is achieved by capturing photons generated during the GEM electron multiplication process by means of a high-resolution camera. The CYGNO experiment has recently developed a TPC Triple GEM detector coupled to a low noise and high spatial resolution CMOS sensor. For the image analysis, an algorithm based on an adapted version of the well-known DBSCAN was implemented, called iDBSCAN. In this paper a description of the iDBSCAN algorithm is given, including test and validation of its parameters, and a comparison with DBSCAN itself and a widely used algorithm known as Nearest Neighbor Clustering (NNC). The results show that the adapted version of DBSCAN is capable of providing full signal detection efficiency and very good energy resolution while improving the detector background rejection.

physics.ins-det↗

Stability and detection performance of a GEM-based Optical Readout TPC with He/CF$_4$ gas mixtures

The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different proportions (60/40 and 70/30) in a CYGNO prototype with 7 litres sensitive volume. With electrical configurations providing very similar electron gains, an almost full detection efficiency in the whole detector volume was found with both mixtures, while a light yield about 20\% larger for the 60/40 was found. The electrostatic stability was tested by monitoring voltages and currents during 25 days. The detector worked in very stable and safe condition for the whole period. In the presence of less CF$_4$, a larger probability of unstable events was clearly detected.

physics.ins-det↗

CYGNO: a gaseous TPC with optical readout for dark matter directional search

The CYGNO project has the goal to use a gaseous TPC with optical readout to detect dark matter and solar neutrinos with low energy threshold and directionality. The CYGNO demonstrator will consist of 1 m 3 volume filled with He:CF 4 gas mixture at atmospheric pressure. Optical readout with high granularity CMOS sensors, combined with fast light detectors, will provide a detailed reconstruction of the event topology. This will allow to discriminate the nuclear recoil signal from the background, mainly represented by low energy electron recoils induced by radioactivity. Thanks to the high reconstruction efficiency, CYGNO will be sensitive to low mass dark matter, and will have the potential to overcome the neutrino floor, that ultimately limits non-directional dark matter searches.

physics.ins-det↗

First evidence of luminescence in a He/CF$_4$ gas mixture induced by non-ionizing electrons

Optical readout of Gas Electron Multipliers (GEM) provides very interesting performances and has been proposed for different applications in particle physics. In particular, thanks to its good efficiency in the keV energy range, it is being developed for low-energy and rare event studies, such as Dark Matter search. So far, the optical approach exploits the light produced during the avalanche processes in GEM channels. Further luminescence in the gas can be induced by electrons accelerated by a suitable electric field. The CYGNO collaboration studied this process with a combined use of a triple-GEM structure and a grid in an He/CF$_4$ (60/40) gas mixture at atmospheric pressure. Results reported in this paper allow to conclude that with an electric field of about 11~kV/cm a photon production mean free path of about 1.0~cm was found.

physics.ins-det↗

High quality factor photonic cavity for dark matter axion searches

Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of $5 \times 10^5$ for a selected mode.

physics.ins-det↗

KLASH Conceptual Design Report

The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals that started a real race towards their discovery. This paper is the Conceptual Design Report of the KLASH (KLoe magnet for Axion SearcH) experiment at the Laboratori Nazionali di Frascati (LNF). The idea of this experiment has been stimulated by the availability of the large volume superconducting magnet, with a moderate magnetic field of 0.6 T, used in the KLOE detector at the DAFNE collider. The main conclusion we draw from this report is the possibility to build and put in operation at LNF in 2-3 years a large haloscope with the sensitivity to KSVZ axions in the low mass range between 0.2 and 1 $μ$eV, complementary to that of other experiments. Timeline and cost are competitive with respect to other proposals in the same mass region thanks to the availability of most of the infrastructure, in particular the superconducting magnet and the cryogenics plant.

physics.ins-det↗

CYGNO: Triple-GEM Optical Readout for Directional Dark Matter Search

CYGNO is a project realising a cubic meter demonstrator to study the scalability of the performance of the optical approach for the readout of large-volume, GEM-equipped TPC. This is part of the CYGNUS proto-collaboration which aims at constructing a network of underground observatories for directional Dark Matter search. The combined use of high-granularity sCMOS and fast sensors for reading out the light produced in GEM channels during the multiplication processes was shown to allow on one hand to reconstruct 3D direction of the tracks, offering accurate energy measurements and sensitivity to the source directionality and, on the other hand, a high particle identification capability very useful to distinguish nuclear recoils. Results of the performed R&D and future steps toward a 30-100 cubic meter experiment will be presented.

physics.ins-det↗

CYGNO: a CYGNUs Collaboration 1 m^3 Module with Optical Readout for Directional Dark Matter Search

The design of the project named CYGNO is presented. CYGNO is a new proposal supported by INFN, the Italian National Institute for Nuclear Physics, within CYGNUs proto-collaboration (CYGNUS-TPC) that aims to realize a distributed observatory in underground laboratories for directional Dark Matter (DM) search and the identification of the coherent neutrino scattering (CNS) from the Sun. CYGNO is one of the first prototypes in the road map to 100-1000 m^3 of CYGNUs and will be located at the National Laboratory of Gran Sasso (LNGS), in Italy, aiming to make significant advances in the technology of single phase gas-only time projection chambers (TPC) for the application to the detection of rare scattering events. In particular it will focus on a read-out technique based on Micro Pattern Gas Detector (MPGD) amplification of the ionization and on the visible light collection with a sub-mm position resolution sCMOS (scientific COMS) camera. This type of readout - in conjunction with a fast light detection - will allow on one hand to reconstruct 3D direction of the tracks, offering accurate sensitivity to the source directionality and, on the other hand, a high particle identification capability very useful to distinguish nuclear recoils.

physics.ins-det↗

Performance of Optically Readout GEM-based TPC with a 55Fe source

Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for low-energy and rare event studies, such as Dark Matter search, ask for demanding performance in the keV energy range. The performance of such a readout was studied in details as a function of the electric field configuration and GEM gain by using a $^{55}$Fe source within a 7 litre sensitive volume detector developed as a part of the R\&D for the CYGNUS project. Results reported in this paper show that the low noise level of the sensor allows to operate with a 2~keV threshold while keeping a rate of fake-events lesser than 10 per year. In this configuration, a detection efficiency well above 95\% along with an energy resolution ($σ$) of 18\% is obtained for the 5.9 keV photons, demonstrating the very promising capabilities of this technique.

physics.ins-det↗

Construction techniques and performances of a full-size prototype Micromegas chamber for the ATLAS muon spectrometer upgrade

A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in constructing the single modules of the chamber in various INFN laboratories and the final assembly at the Laboratori Nazionali di Frascati (LNF). Results of the chamber exposure to the CERN SPS/H8 beam line in June 2016 are also presented. The performances achieved in the construction and the results of the test beam are compared with the requirements, which are imposed by the severe environment during the data-taking of the LHC foreseen for the next years.

physics.ins-det↗