SearcharxivSearch

arXiv subjects

G. Mazza

Publications and source records attributed to G. Mazza.

16 recordsLinked to original sources

HASPIDE-SPACE: a new concept of a radiation-resistant instrument for solar energetic particles

Galactic cosmic rays and solar energetic particles (SEPs) affect the performance of instruments carried on board space missions and are the source of the absorbed dose to astronauts. Particles above 100 MeV are the most penetrating. The overall particle flux impacting spacecraft increases by several orders of magnitude during the most intense SEP events and gamma-ray bursts, compared to the galactic cosmic-ray background. Unfortunately, most detectors dedicated to the monitoring of solar particles in space do not allow measurements above 200 MeV. Space agencies and the space and heliospheric weather communities are interested in improving this scenario. We propose a new, compact, low-power, and radiation-resistant instrument, intended for long-duration missions to monitor solar X-rays, electrons, and protons up to energies of tens of keV, MeV, and 600 MeV, respectively. Intense long and short gamma-ray bursts would be observed in the absence of solar activity.

hep-ex

Proton irradiation on Hydrogenated Amorphous Silicon flexible devices

Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices had two different configurations and thicknesses. The first device was a 2 um thick n-i-p diode having a 5 mm x 5 mm area. The second device was a 5 um thick charge selective contact detector having the same area. Both the devices were deposited on a flexible polyimide substrate and were irradiated up to the fluence of 1016 neq/cm2. The response to different proton fluxes has been measured before irradiation and after irradiation at 1016 neq/cm2 for charge-selective contacts and n-i-p devices. The effect of annealing for partial performance recovery at 100{\deg}C for 12 hours was also studied and a final characterization on annealed devices was performed. This test is the first combined displacement and total ionizing dose test on flexible a-Si:H devices.

physics.ins-det

Characterization of hydrogenated amorphous silicon sensors on polyimide flexible substrate

Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these properties a-Si:H can be used for the production of flexible sensors. a-Si:H sensors can be successfully utilized in dosimetry, beam monitoring for particle physics (x-ray, electron, gamma-ray and proton detection) and radiotherapy, radiation flux measurement for space applications (study of solar energetic particles and stellar events) and neutron flux measurements. In this paper we have studied the dosimetric x-ray response of n-i-p diodes deposited on Polyimide. We measured the linearity of the photocurrent response to x-rays versus dose-rate from which we have extracted the dosimetric x-ray sensitivity at various bias voltages. In particular low bias voltage operation has been studied to assess the high energy efficiency of these kind of sensor. A measurement of stability of x-ray response versus time has been shown. The effect of detectors annealing has been studied. Operation under bending at various bending radii is also shown.

physics.ins-det

Exciton condensation in strongly correlated quantum spin Hall insulators

Time reversal symmetric topological insulators are generically robust with respect to weak local interaction, unless symmetry breaking transitions take place. Using dynamical mean-field theory we solve an interacting model of quantum spin Hall insulators and show the existence, at intermediate coupling, of a symmetry breaking transition to a non-topological insulator characterised by exciton condensation. This transition is of first order. For a larger interaction strength the insulator evolves into a Mott one. The transition is continuous if magnetic order is prevented, and notably, for any finite Hund's exchange it progresses through a Mott localization before the condensate coherence is lost. We show that the correlated excitonic state corresponds to a magneto-electric insulator which allows for direct experimental probing. Finally, we discuss the fate of the helical edge modes across the excitonic transition.

cond-mat.str-el

Development of thin hydrogenated amorphous silicon detectors on a flexible substrate

The HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project aims at the development of thin hydrogenated amorphous silicon (a-Si:H) detectors on flexible substrates (mostly Polyimide) for beam monitoring, neutron detection and space applications. Since a-Si:H is a material with superior radiation hardness, the benefit for the above-mentioned applications can be appreciated mostly in radiation harsh environments. Furthermore, the possibility to deposit this material on flexible substrates like Polyimide (PI), polyethylene naphthalate (PEN) or polyethylene terephthalate (PET) facilitates the usage of these detectors in medical dosimetry, beam flux and beam profile measurements. Particularly interesting is its use when positioned directly on the flange of the vacuum-to-air separation interface in a beam line, as well as other applications where a thin self-standing radiation flux detector is envisaged. In this paper, the HASPIDE project will be described and some preliminary results on PI and glass substrates will be reported.

physics.ins-det

Data acquisition system for a 146-channel counter of protons in particle therapy

A prototype of proton counter was developed by the University and the National Institute for Nuclear Physics of Torino to be used as online fluence beam monitor in particle therapy. The single particle identification approach aims at increasing the sensitivity and readout speed with respect to the state-of-the-art gas ionization chambers. The sensitive area is 2,7 x 2,7 cm^2 to cover the clinical beam cross section characterized by a full width at half maximum of about 1 cm at the isocenter. The sensor is a thin Low Gain Avalanche Diode segmented in 146 strips with 180 micrometer pitch and with 50 micrometer active thickness, designed and produced by the Fondazione Bruno Kessler (Trento, Italy). The frontend readout to identify the single proton signal provided by each strip is based on a 24channel custom ASICs, named ABACUS, optimized to discriminate the signal pulses in a wide charge range (3-150 fC) with a maximum dead-time of 10 ns. With these specifications, at the maximum fluence rate of 10^8 p/(cm^2s) in the clinical energy range (60-230 MeV) and considering the silicon strips described above, a maximum pileup counting inefficiency less than 1 percent is achieved. A frontend board housing 6 ABACUS chips to readout the 146 strips was developed, the digital outputs being sent to 3 FPGAs (Kintex7) for the counting. A LabVIEW program implements the interface with the FPGAs, displays online the counting rate from each strip and stores the data for offline analysis.

physics.ins-det

EDIpack: A parallel exact diagonalization package for quantum impurity problems

We present EDIpack, an exact diagonalization package to solve generic quantum impurity problems. The algorithm includes a generalization of the look-up method introduced in [Lin, Gubernatis Comput. Phys., 7 (4) (1993), 400] and enables a massively parallel execution of the matrix-vector linear operations required by Lanczos and Arnoldi algorithms. We show that a suitable Fock basis organization is crucial to optimize the inter-processors communication in a distributed memory setup and to reach sub-linear scaling in sufficiently large systems. We discuss the algorithm in details indicating how to deal with multiple orbitals and electron-phonon coupling. Finally, we outline the download, installation and functioning of the package.

physics.comp-ph

A new detector for the beam energy measurement in proton therapy: a feasibility study

Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy could allow assessing the range of penetration during treatments, encouraging the development of new dose delivery techniques for moving targets. Towards this end, the proof of concept of a new device, able to measure in a few seconds the energy of clinical proton beams (from 60 to 230 MeV) from the Time of Flight (ToF) of protons, is presented. The prototype consists of two Ultra Fast Silicon Detector (UFSD) pads, featuring an active thickness of 80 um and a sensitive area of 3 x 3 mm2, aligned along the beam direction in a telescope configuration, connected to a broadband amplifier and readout by a digitizer. Measurements were performed at the Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy), at five different clinical beam energies and four distances between the sensors (from 7 to 97 cm) for each energy. In order to derive the beam energy from the measured average ToF, several systematic effects were considered, Monte Carlo simulations were developed to validate the method and a global fit approach was adopted to calibrate the system. The results were benchmarked against the energy values obtained from the water equivalent depths provided by CNAO. Deviations of few hundreds of keV have been achieved for all considered proton beam energies for both 67 and 97 cm distances between the sensors and few seconds of irradiation were necessary to collect the required statistics. These preliminary results indicate that a telescope of UFSDs could achieve in a few seconds the accuracy required for the clinical application and therefore encourage further investigations towards the improvement and the optimization of the present prototype.

physics.med-ph

Field-driven Mott gap collapse and resistive switch in correlated insulators

Mott insulators can be portrayed as "unsuccessful metals": systems in which a strong Coulomb repulsion prevents charge conduction notwithstanding the metal-like density of conduction electrons. The possibility to unlock such large density of frozen carriers with an electric field offers a tantalizing opportunity to realize new Mott-based microelectronic devices. Here we explicitly unveil how such unlocking happens by solving a simple, yet generic, model for correlated insulators using dynamical mean-field theory. Specifically, we show that the electric breakdown of a Mott insulator can occur via a first-order insulator-to-metal transition, characterized by an abrupt gap-collapse in sharp contrast to the Zener tunneling mechanism. The switch-on of charge conduction is due to the energetic stabilization of a metallic phase that preexists as metastable state in equilibrium and is disconnected from the stable insulator. Our findings rationalize recent experimental observations and offer a guideline for future technological research.

cond-mat.str-el

Electronic transport and dynamics in correlated heterostructures

We investigate by means of the time-dependent Gutzwiller approximation the transport properties of a strongly-correlated slab subject to Hubbard repulsion and connected with to two metallic leads kept at a different electrochemical potential. We focus on the real-time evolution of the electronic properties after the slab is connected to the leads and consider both metallic and Mott insulating slabs. When the correlated slab is metallic, the system relaxes to a steady-state that sustains a finite current. The zero-bias conductance is finite and independent of the degree of correlations within the slab as long as the system remains metallic. On the other hand, when the slab is in a Mott insulating state, the external bias leads to currents that are exponentially activated by charge tunneling across the Mott-Hubbard gap, consistent with the Landau-Zener dielectric breakdown scenario.

cond-mat.str-el

Performance of Ultra-Fast Silicon Detectors

The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche Detectors, and in particular we demonstrate the possibility of obtaining ultra-fast silicon detector with time resolution of less than 20 picosecond.

physics.ins-det

Kinks and waterfalls as signatures of competing order in angle-resolved photoemission spectra of La_{2-x}Sr_xCuO_4

We show that the so-called kinks and waterfalls observed in angle-resolved photoemission spectra of La2-xSrxCuO4, a prototypical high-Tc superconducting cuprate, result from the coupling of quasiparticles with two distinct nearly critical collective modes with finite characteristic wave vectors, typical of charge and spin fluctuations near a stripe instability. Both phonon-like charge and spin collective modes are needed to account for the kinked quasiparticle dispersions. This clarifies the long-standing question whether kinks are due to phonons or spin waves and the nature of the bosonic mediators of the electron-electron effective interaction in La2-xSrxCuO4.

cond-mat.supr-con

Charge collection in the Silicon Drift Detectors of the ALICE experiment

A detailed study of charge collection efficiency has been performed on the Silicon Drift Detectors (SDD) of the ALICE experiment. Three different methods to study the collected charge as a function of the drift time have been implemented. The first approach consists in measuring the charge at different injection distances moving an infrared laser by means of micrometric step motors. The second method is based on the measurement of the charge injected by the laser at fixed drift distance and varying the drift field, thus changing the drift time. In the last method, the measurement of the charge deposited by atmospheric muons is used to study the charge collection efficiency as a function of the drift time. The three methods gave consistent results and indicated that no charge loss during the drift is observed for the sensor types used in 99% of the SDD modules mounted on the ALICE Inner Tracking System. The atmospheric muons have also been used to test the effect of the zero-suppression applied to reduce the data size by erasing the counts in cells not passing the thresholds for noise removal. As expected, the zero suppression introduces a dependence of the reconstructed charge as a function of drift time because it cuts the signal in the tails of the electron clouds enlarged by diffusion effects. These measurements allowed also to validate the correction for this effect extracted from detailed Monte Carlo simulations of the detector response and applied in the offline data reconstruction.

physics.ins-det

Beam test results of the irradiated Silicon Drift Detector for ALICE

The Silicon Drift Detectors will equip two of the six cylindrical layers of high precision position sensitive detectors in the ITS of the ALICE experiment at LHC. In this paper we report the beam test results of a SDD irradiated with 1 GeV electrons. The aim of this test was to verify the radiation tolerance of the device under an electron fluence equivalent to twice particle fluence expected during 10 years of ALICE operation.

physics.ins-det

APENet: LQCD clusters a la APE

Developed by the APE group, APENet is a new high speed, low latency, 3-dimensional interconnect architecture optimized for PC clusters running LQCD-like numerical applications. The hardware implementation is based on a single PCI-X 133MHz network interface card hosting six indipendent bi-directional channels with a peak bandwidth of 676 MB/s each direction. We discuss preliminary benchmark results showing exciting performances similar or better than those found in high-end commercial network systems.

hep-lat

Technology Update of a Control System Trough Corba Bus

After more than 10 years of activity, FTU (Frascati Tokamak Upgrade) has to face the problem of taking advantage of the new hardware and software technology saving all the investments yet done. So, for example, the 20 years old Westinghouse PLCs (communicating only through a serial line) have to be leaved in operation while a web-based tool has to be released for plan monitoring purpose. CORBA bus has been demonstrated to be the answer to set up the communication between old and new hardware and software blocks. On FTU the control system is based on Basestar, a Digital/Compaq software suite. We will describe how the real time database of Basestar is now accessed by Java graphic tools, LabView and, in principle, any package accepting external routines. An account will be also done in the data acquisition area where a Camac serial highway driver has been integrated in the new architecture still through the CORBA bus

physics.acc-ph