SearcharxivSearch

arXiv subjects

G. Menon

Publications and source records attributed to G. Menon.

At least 19 recordsLinked to original sources

Long term experience with perfluorobutane in COMPASS RICH

COMPASS RICH-1 has used high-purity perfluorobutane as radiator gas since 2001. The operation and control of the radiator gas has evolved over years with continuous improvements. We report on the experience gained in the 20 year-long operation of perfluorobutane as COMPASS RICH radiator. Very accurate values for the radiator gas refractive index are needed for high-performance particle identification. The procedure has evolved over years and the one presently in use, which provides refractive index estimate at the 1 ppm level, is discussed. Perfluorobutane procurement is becoming challenging, and the minimization of material waste is now a priority for the protection of the environment. Commercially available perfluorobutane needs dedicated filtering before usage and typical material losses in the filtering procedure were around 30%. Recent efforts allowed us to reduce them to about 5%. A potential alternative to fluorocarbon radiators in gaseous RICHes is also presented.

physics.ins-det

MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond

COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly developed MPGD-based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a Micromegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during the 2016 COMPASS data taking and stably operated during the 2017 run. In this paper design, construction, operation and performance aspects of the novel photon detectors for COMPASS RICH-1 are discussed.

physics.ins-det

Nanodiamond photocathodes for MPGD-based single photon detectors at future EIC

We are developing gaseous photon detectors for Cherenkov imaging applications in the experiments at the future Electron Ion Collider. CsI, converting photons in the far ultraviolet range, is, so far, the only photoconverter compatible with the operation of gaseous detectors. It is very delicate to handle due to its hygroscopic nature: the absorbed water vapour decomposes the CsI molecule. In addition, its quantum efficiency degrades under ion bombardment. These are the key reasons to quest for novel, less delicate materials for photocathodes adequate for gaseous photon detectors. Layers of hydrogenated nanodiamond particles have recently been proposed as an alternative material and have shown promising characteristics. The performance of nanodiamond photocathodes coupled to thick GEM-based detectors is the object of our ongoing R\&D. The first phase of these studies includes the characterization of thick GEM coated with nanodiamond layers and the robustness of its photoconverting properties with respect to the bombardment by ions from the multiplication process in the gaseous detector. The approach is described in detail as well as all the results obtained so far within these exploratory studies.

physics.ins-det

Direct measurements of the properties of Thick-GEM reflective photocathodes

In the context of the development of novel Thick GEM based detectors of single photons, the high resolution optical system, nicknamed Leopard, providing a detailed surface scanning of the Thick GEM electron multipliers, has been used for a set of systematic measurements of key Thick GEM properties. These results are reported and discussed. They confirm by direct observation Thick GEM properties previously inferred by indirect measurements and answer to relevant questions related to the use of Thick GEMs as photocathode substrates in novel gaseous photon detectors.

physics.ins-det

A modular mini-pad photon detector prototype for RICH application at the Electron Ion Collider

Experiments at the future Electron Ion Collider require excellent hadron identification in a broad momentum range, in harsh conditions. A RICH capable to fulfill the PID requirements of the EIC could use MPGD-based photon detectors with solid photocathodes for covering large surfaces at affordable cost, providing good efficiency, high resolution and compatibility with magnetic field. Photon detectors realized by coupling THGEMs and Micromegas have been successfully operated at the RICH-1 detector of the COMPASS Experiment at CERN since 2016. A similar technology could be envisaged for an EIC RICH, provided a large improvement in the photon position resolution is achieved. An R\&D effort in this direction is ongoing at INFN Trieste. Few prototypes with smaller pixel size (down to 3 mm x 3 mm) have been built and tested in the laboratory with X-Ray and UV LED light sources. A modular mini-pad detector prototype has also been tested at the CERN SPS H4 beamline. New data acquisition and analysis software called Raven DAQ and Raven Decoder have been developed and used with the APV-25 based Scalable Readout System (SRS), for the modular mini-pad prototype tests.

physics.ins-det

Nanodiamond photocathodes for MPGD-based single photon detectors at future EIC

The design of a Ring Imaging CHerenkov (RICH) detector for the identification of high momentum particles at the future Electron Ion Collider (EIC) is extremely challenging by using current technology. Compact collider setups impose to construct RICH with short radiator length, hence limiting the number of generated photons. The number of detected photons can be increased by selecting the far UV region. As standard fused-silica windows is opaque below 165 nm, a windowless RICH can be a possible approach. CsI is widely used photocathode (PC) for photon detection in the far UV range. Due to its hygroscopic nature it is very delicate to handle. In addition, its Quantum Efficiency (QE) degrades in high intensity ion fluxes. These are the key reasons to quest for novel PC with sensitivity in the far UV region. Recent development of layers of hydrogenated nanodiamond powders as an alternative PC material and their performance, when coupled to the THick Gaseous Electron Multipliers (THGEM)-based detectors, are the objects of an ongoing R\&D. We report here some preliminary results on the initial phase of these studies.

physics.ins-det

The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1

After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance. Perspectives for further developments in the field of gaseous single photon detectors are also indicated.

physics.ins-det

The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1

The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MicroMegas anode is segmented into pads individually biased with positive voltage while the micromesh is grounded. In total, there are about ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels, where appropriate correlations among the applied voltages are required for the correct operation of the detectors. Therefore, a robust control system is mandatory, implemented by a custom designed software package, while commercial power supply units are used. This sophisticated control system allows to protect the detectors against errors by the operator, to monitor and log voltages and currents at 1 Hz rate, and automatically react to detector misbehaviour. In addition, a voltage compensation system has been developed to automatically adjust the biasing voltage according to environmental pressure and temperature variations, to achieve constant gain over time. This development answers to a more general need. In fact, voltage compensation is always a requirement for the stability of gaseous detectors and its need is enhanced in multi-layer ones. In this paper, the HV system and its performance are described in details, as well as the stability of the novel MPGD-based photon detectors during the physics data taking at COMPASS.

physics.ins-det

The Hybrid MPGD-based photon detectors of COMPASS RICH-1

Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.

physics.ins-det

Study of MicroPattern Gaseous detectors with novel nanodiamond based photocathodes for single photon detection in EIC RICH

Identification of high momentum hadrons at the future EIC is crucial, gaseous RICH detectors are therefore viable option. Compact collider setups impose to construct RICHes with small radiator length, hence significantly limiting the number of detected photons. More photons can be detected in the far UV region, using a windowless RICH approach. QE of CsI degrades under strong irradiation and air contamination. Nanodiamond based photocathodes (PCs) are being developed as an alternative to CsI. Recent development of layers of hydrogenated nanodiamond powders as an alternative photosensitive material and their performance, when coupled to the THick Gaseous Electron Multipliers (THGEM)-based detectors, are the objects of an ongoing R\&D. We report about the initial phase of our studies.

physics.ins-det

Optimized MPGD-based Photon Detectors for high momentum particle identification at the Electron-Ion Collider

Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the radiator region available at a collider experiment. By selecting a photon wavelength range in the far UV domain, around 120 nm, the number of detectable photons can be increased. Ideal sensors are gaseous Photon Detectors (PD) with CsI photocathode, where the status of the art is represented by the MPGD-based PDs at COMPASS RICH. Detector optimization is required for the application at EIC. Here we report about a dedicated prototype where the sensor pad-size has been reduced to preserve the angular resolution. A new DAQ system based on the SRS readout electronics has been developed for the laboratory and test beam studies of the prototype.

physics.ins-det

The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond

After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance. Perspectives for further developments in the field of gaseous single photon detectors are also presented.

physics.ins-det

New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system

The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the signals also in the intermediate Induction 2 wire plane with a significant increase of signal to noise (S/N), allowing for charge measurement also in this view. The new front-end and the analog to digital conversion (ADC) system are presented together with the results of the tests on 50 liters liquid argon TPC performed at CERN with cosmic rays.

physics.ins-det

The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1

The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.

physics.ins-det

RHIP, a Radio-controlled High-Voltage Insulated Picoammeter and its usage in studying ion backflow in MPGD-based photon detectors

A picoammeter system has been developed and engineering. It consists in a current-voltage converter, based on an operational amplifier with very low input current, a high precision ADC, a radio controlled data acquisition unit and the computer-based control, visualization and storage. The precision is of the order of a tenth of picoampers and it can measure currents between electrodes at potentials up to 8 kV. The system is battery powered and a number of strategies have been implemented to limit the power consumption. The system is designed for multichannel applications, up to 256 parallel channels. The overall implementation is cost-effective to make the availability of multichannel setups easily affordable. The design, implementation and performance of the picoammeter system are described in detail as well as a an application: the measurement of ion backflow in MPGD-based photon detectors.

physics.ins-det

The high voltage system for the novel MPGD-based photon detectors of COMPASS RICH-1

The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at positive voltage, while the micromesh is grounded. In total, there are ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels. Commercial power supply units are used. The original elements of the power supply system are the architecture of the voltage distribution net, the compensation, by voltage adjustment, of the effects of pressure and temperature variation affecting the detector gain and a sophisticated control software, which allows to protect the detectors against errors by the operator, to monitor and log voltages and current at 1 Hz rate and to automatically react to detector misbehaviors. The HV system and its performance are described in detail as well as the electrical stability of the detector during the operation at COMPASS.

physics.ins-det

Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors

A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.

physics.ins-det

Novel MPGD based Detectors of Single Photons in COMPASS RICH-1

COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.

physics.ins-det