SearcharxivSearch

arXiv subjects

G. Mishra

Publications and source records attributed to G. Mishra.

5 recordsLinked to original sources

Measurement of neutron induced reaction cross-section of tantalum with covariance analysis

The current study presents the cross-section measurement of $^{181}$Ta(n,$\gamma$)$^{182}$Ta reaction at 1.37 $\pm$ 0.13, 2.06 $\pm$ 0.14, 2.56 $\pm$ 0.15, and 3.05 $\pm$ 0.17 MeV neutron energies utilizing offline $\gamma$-ray spectroscopy. The neutrons were generated through the $^{7}$Li(p,n)$^{7}$Be reaction. The $^{115}$In(n,n'$\gamma$)$^{115m}$In reaction served as a monitor reaction. The covariance analysis was used to quantify the uncertainties in the measured cross-sections for the first time for the $^{181}$Ta(n,$\gamma$)$^{182}$Ta reaction. The present study provides detailed information on the propagation of uncertainty in the overall result. The required corrections for low energy background neutron and $\gamma$-ray coincidence summing effect have been made in the present measurement. The output is compared with the pre-existing cross-section data from the EXFOR database, evaluated data libraries and theoretical model predictions.

nucl-ex

Uncertainty propagation and covariance analysis of 181Ta(n,{\gamma})182Ta nuclear reaction

The neutron capture cross-section for the $^{181}$Ta(n,$\gamma$)$^{182}$Ta reaction has been experimentally measured at the neutron energies 0.53 and 1.05 MeV using off-line $\gamma$-ray spectrometry. $^{115}$In(n,n'$\gamma$)$^{115m}$In is used as a reference monitor reaction cross-section. The neutron was produced via the $^{7}$Li(p,n)$^{7}$Be reaction. The present study measures the cross-sections with their uncertainties and correlation matrix. The self-attenuation process, $\gamma$-ray correction factor, and low background neutron energy contribution have been calculated. The measured neutron spectrum averaged cross-sections of $^{181}$Ta(n,$\gamma$)$^{182}$Ta are discussed and compared with the existing data from the EXFOR database and also with the ENDF/B-VIII.0, TENDL-2019, JENDL-5, JEFF-3.3 evaluated data libraries.

nucl-ex

Measurement of the response of a liquid scintillation detector to monoenergetic electrons and neutrons

The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination and pulse height response of the liquid scintillator for neutrons has been measured using $^7$Li(p,n$_1$)$^7$Be*(0.429 MeV) reaction. Non linear response to mono-energetic neutrons for the liquid scintillator is observed at E$_n$=5.3, 9.0 and 12.7 MeV. The measured response of the liquid scintillator for electrons and neutrons have been compared with Geant4 simulation.

physics.ins-det

Giant Dipole Resonance studies in Ba isotopes at $\textbf{ E/A}\sim$ 5 MeV

Exclusive measurements of high energy $γ$-rays are performed in $\rm ^{124}Ba$ and $\rm ^{136}Ba$ at the same excitation energy ($\sim$ 49 MeV), to study properties of the giant dipole resonance (GDR) over a wider $N/Z$ range. The high energy $γ$-rays are measured in coincidence with the multiplicity of low energy $γ$-rays to disentangle the effect of temperature ($T$) and angular momentum ($J$). The GDR parameters are extracted employing a simulated Monte Carlo statistical model analysis. The observed $γ$-ray spectra of $\rm ^{124}Ba$ can be explained with prolate deformation, whereas a single component Lorentzian function which corresponds to a spherical shape could explain the $γ$-ray spectra from $\rm ^{136}Ba$. The observed GDR width in $\rm ^{136}Ba$ is narrower compared to that of $\rm ^{124}Ba$. The statistical model best fit GDR cross sections are found to be in good agreement with the thermal shape fluctuation model (TSFM) calculations. Further, it is shown that the variation of GDR width with $T$ is well reproduced by the TSFM calculations over the temperature range of 1.1--1.7MeV.

nucl-ex

Characterization of PARIS LaBr$_3$(Ce)-NaI(Tl) phoswich detectors upto $E_γ$ $\sim$ 22 MeV

In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out. The detector response is investigated over a wide range of $E_γ$ = 0.6 to 22.6 MeV using radioactive sources and employing $^{11}B(p,γ)$ reaction at $E_p$ = 163 keV and $E_p$ = 7.2 MeV. The linearity of energy response of the LaBr$_3$(Ce) detector is tested upto 22.6 MeV using three different voltage dividers. The data acquisition system using CAEN digitizers is set up and optimized to get the best energy and time resolution. The energy resolution of $\sim$ 2.1% at $E_γ$ = 22.6~MeV is measured for the configuration giving best linearity upto high energy. Time resolution of the phoswich detector is measured with a $^{60}$Co source after implementing CFD algorithm for the digitized pulses and is found to be excellent (FWHM $\sim$ 315~ps). In order to study the effect of count rate on detectors, the centroid position and width of the $E_γ$ = 835~keV peak were measured upto 220 kHz count rate. The measured efficiency data with radioactive sources are in good agreement with GEANT4 based simulations. The total energy spectrum after the add-back of energy signals in phoswich components is also presented.

physics.ins-det