SearcharxivSearch

arXiv subjects

G. Ottonello

Publications and source records attributed to G. Ottonello.

3 recordsLinked to original sources

The measurement of late-pulses and after-pulses in the large area Hamamatsu R7081 photomultiplier with improved quantum-efficiency photocathode

In recent years, large underwater telescopes have been designed and realized to measure high energy neutrinos from astrophysical objects. Muon tracks produced by the neutrino interaction in the surrounding medium are reconstructed from the arrival time and the number of photo-electrons of the Cherenkov light measured by the Photomultiplier tubes (PMT) array of the detector. For a correct reconstruction procedure, both the scattering of the light in the water and the late and after pulses produced in the PMTs must be considered. In this paper we report on this latter effect which has been measured in our laboratory using a laser in the single photoelectron mode (SPE) on a Hamamatsu R7081MOD 10" PMT with a high quantum efficiency photocathode. The PMT voltage supply was set to provide the 1 photo-electron peak at 10 pC as during normal operation: in this condition we find that the late-pulse contribution is small but not negligible.

physics.ins-det

The BDX-MINI detector for Light Dark Matter search at JLab

This paper describes the design and performance of a compact detector, BDX-MINI, that incorporates all features of a concept that optimized the detection of light dark matter produced by electrons in a beam dump. It represents a reduced version of the future BDX experiment expected to run at JLAB. BDX-MINI was exposed to penetrating particles produced by a 2.176 GeV electron beam incident on the beam dump of Hall A at Jefferson Lab. The detector consists of 30.5 kg of PbWO4 crystals with sufficient material following the beam dump to eliminate all known particles except neutrinos. The crystals are read out using silicon photomultipliers. Completely surrounding the detector are a passive layer of tungsten and two active scintillator veto systems, which are also read out using silicon photomultipliers. The design was validated and the performance of the robust detector was shown to be stable during a six month period during which the detector was operated with minimal access.

physics.ins-det

Comparison of Fast Amplifiers for Diamond Detectors

The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a number of commercial amplifiers designed for diamond detector readout to identify the best solution for a particular application. This application required a deposited energy threshold below 100 keV and timing resolution of the order of 200 ps at 200 keV. None of tested amplifiers satisfies these requirements. The best solution to such application found to be the Cividec C6 amplifier, which allows 100 keV minimal threshold, but its coincidence timing resolution at 200 keV is as large as 1.2 ns.

physics.ins-det