Searcharxiv⌕ Search

arXiv subjects

G. Pascual-Cisneros

Publications and source records attributed to G. Pascual-Cisneros.

20 records · Page 2Linked to original sources

Tensor-to-scalar ratio forecasts for extended LiteBIRD frequency configurations

LiteBIRD is a planned JAXA-led CMB B-mode satellite experiment aiming for launch in the late 2020s, with a primary goal of detecting the imprint of primordial inflationary gravitational waves. Its current baseline focal-plane configuration includes 15 frequency bands between 40 and 402 GHz, fulfilling the mission requirements to detect the amplitude of gravitational waves with the total uncertainty on the tensor-to-scalar ratio, $δr$, down to $δr<0.001$. A key aspect of this performance is accurate astrophysical component separation, and the ability to remove polarized thermal dust emission is particularly important. In this paper we note that the CMB frequency spectrum falls off nearly exponentially above 300 GHz relative to the thermal dust SED, and a relatively minor high frequency extension can therefore result in even lower uncertainties and better model reconstructions. Specifically, we compare the baseline design with five extended configurations, while varying the underlying dust modeling, in each of which the HFT (High-Frequency Telescope) frequency range is shifted logarithmically towards higher frequencies, with an upper cutoff ranging between 400 and 600 GHz. In each case, we measure the tensor-to-scalar ratio $r$ uncertainty and bias using both parametric and minimum-variance component-separation algorithms. When the thermal dust sky model includes a spatially varying spectral index and temperature, we find that the statistical uncertainty on $r$ after foreground cleaning may be reduced by as much as 30--50 % by extending the upper limit of the frequency range from 400 to 600 GHz, with most of the improvement already gained at 500 GHz. We also note that a broader frequency range leads to better ability to discriminate between models through higher $χ^2$ sensitivity. (abridged)

astro-ph.CO↗

Polarization Calibration of a Microwave Polarimeter with Near-Infrared Up-Conversion for Optical Correlation and Detection

This paper presents a polarization calibration method applied to a microwave polarimeter demonstrator based on a near-infrared (NIR) frequency up-conversion stage that allows both optical correlation and signal detection at a wavelength of 1550 nm. The instrument was designed to measure the polarization of cosmic microwave background (CMB) radiation from the sky, obtaining the Stokes parameters of the incoming signal simultaneously, in a frequency range from 10 to 20 GHz. A linearly polarized input signal with a variable polarization angle is used as excitation in the polarimeter calibration setup mounted in the laboratory. The polarimeter systematic errors can be corrected with the proposed calibration procedure, achieving high levels of polarization efficiency (low polarization percentage errors) and low polarization angle errors. The calibration method is based on the fitting of polarization errors by means of sinusoidal functions composed of additive or multiplicative terms. The accuracy of the fitting increases with the number of terms in such a way that the typical error levels required in low-frequency CMB experiments can be achieved with only a few terms in the fitting functions. On the other hand, assuming that the calibration signal is known with the required accuracy, additional terms can be calculated to reach the error levels needed in ultrasensitive B-mode polarization CMB experiments.

astro-ph.IM↗