SearcharxivSearch

arXiv subjects

G. Pettinari

Publications and source records attributed to G. Pettinari.

15 recordsLinked to original sources

A chemically etched D-band waveguide orthomode transducer for CMB measurements

This study presents a prototype D-band waveguide orthomode transducer (OMT) fabricated using chemically etched brass platelets. This method offers a fast, cost-effective, and scalable approach for producing waveguide OMTs above 100 GHz, making it well-suited for current and future Cosmic Microwave Background polarization experiments, where large focal planes with thousands of receivers are required to detect the faint primordial \textit{B}-modes. Chemical etching has already demonstrated its effectiveness in manufacturing corrugated feedhorn arrays with state-of-the-art performance up to 150 GHz. Here, we evaluate its applicability to more complex structures, such as OMTs. We designed a single OMT prototype operating in the 130-170 GHz range, fabricated by chemically etching 0.15 mm-thick brass plates, which were then stacked, aligned, and mechanically clamped. Simulations based on metrological measurements of the OMT profile predict return losses below $-$10 dB, isolation better than $-$30 dB, and transmission around $-$0.5 dB. The measured transmission and isolation, however, is around $-$1.5/$-$2 dB and $<-$20 dB, respectively. Further simulations show that the degradation in the transmission is related to defects and roughness along the etched profile ($\mathrm{RMS}\simeq$3 $μ$m), which is a typical and unavoidable effect of chemical etching. The discrepancy in isolation, instead, could arise from a slight rotation ($\sim$3$^{\circ}$) of the polarization angle within the measurement chain. Our results show that chemical etching is a fast, low-cost, and scalable technique for producing waveguide OMTs with state-of-the-art performance in terms of return loss and isolation. However, at frequencies above 100 GHz the transmission coefficient may degrade due to the mechanical precision limitations of chemical etching.

astro-ph.IM

Measuring the CMB spectral distortions with COSMO: the multi-mode antenna system

In this work, we present the design and manufacturing of the two multi-mode antenna arrays of the COSMO experiment and the preliminary beam pattern measurements of their fundamental mode compared with simulations. COSMO is a cryogenic Martin-Puplett Fourier Transform Spectrometer that aims at measuring the isotropic y-type spectral distortion of the Cosmic Microwave Background from Antarctica, by performing differential measurements between the sky and an internal, cryogenic reference blackbody. To reduce the atmospheric contribution, a spinning wedge mirror performs fast sky-dips at varying elevations while fast, low-noise Kinetic Inductance detectors scan the interferogram. Two arrays of antennas couple the radiation to the detectors. Each array consists of nine smooth-walled multi-mode feed-horns, operating in the $120-180$ GHz and $210-300$ GHz range, respectively. The multi-mode propagation helps increase the instrumental sensitivity without employing large focal planes with hundreds of detectors. The two arrays have a step-linear and a linear profile, respectively, and are obtained by superimposing aluminum plates made with CNC milling. The simulated multi-mode beam pattern has a $\sim 20^{\circ} - 26^{\circ}$ FWHM for the low-frequency array and $\sim 16^{\circ}$ FWHM for the high-frequency one. The side lobes are below $-15$ dB. To characterize the antenna response, we measured the beam pattern of the fundamental mode using a Vector Network Analyzer, in far-field conditions inside an anechoic chamber at room temperature. We completed the measurements of the low-frequency array and found a good agreement with the simulations. We also identified a few non-idealities that we attribute to the measuring setup and will further investigate. A comprehensive multi-mode measurement will be feasible at cryogenic temperature once the full receiver is integrated.

astro-ph.IM

Observing galaxy clusters and the cosmic web through the Sunyaev Zel'dovich effect with MISTRAL

Galaxy clusters and surrounding medium, can be studied using X-ray bremsstrahlung emission and Sunyaev Zel'dovich (SZ) effect. Both astrophysical probes, sample the same environment with different parameters dependance. The SZ effect is relatively more sensitive in low density environments and thus is useful to study the filamentary structures of the cosmic web. In addition, observations of the matter distribution require high angular resolution in order to be able to map the matter distribution within and around galaxy clusters. MISTRAL is a camera working at 90GHz which, once coupled to the Sardinia Radio Telescope, can reach $12''$ angular resolution over $4'$ field of view (f.o.v.). The forecasted sensitivity is $NEFD \simeq 10-15mJy \sqrt{s}$ and the mapping speed is $MS= 380'^{2}/mJy^{2}/h$. MISTRAL was recently installed at the focus of the SRT and soon will take its first photons.

astro-ph.CO

BULLKID: Monolithic array of particle absorbers sensed by Kinetic Inductance Detectors

We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prototype presented consists of an array of 64 dices of 5.4x5.4x5 mm$^3$ carved in a 3" diameter, 5 mm thick silicon wafer, with a common disk 0.5 mm thick hosting a 60 nm patterned aluminum layer. The resulting array is highly segmented but avoids the use of dedicated holding structures for each unit. Despite the fact that the uniformity of the KID electrical response across the array needs optimization, the operation of 8 units with similar features shows, on average, a baseline energy resolution of $26\pm7$ eV. This makes it a suitable detector for low-energy processes such as direct interactions of dark matter and coherent elastic neutrino-nucleus scattering.

physics.ins-det

Total power horn-coupled 150 GHz LEKID array for space applications

We have developed two arrays of lumped element kinetic inductance detectors working in the D-band, and optimised for the low radiative background conditions of a satellite mission aiming at precision measurements of the Cosmic Microwave Background (CMB). The first detector array is sensitive to the total power of the incoming radiation to which is coupled via single-mode waveguides and corrugated feed-horns, while the second is sensitive to the polarisation of the radiation thanks to orthomode transducers. Here, we focus on the total power detector array, which is suitable, for instance, for precision measurements of unpolarised spectral distortions of the CMB, where detecting both polarisations provides a sensitivity advantage. We describe the optimisation of the array design, fabrication and packaging, the dark and optical characterisation, and the performance of the black-body calibrator used for the optical tests. We show that almost all the detectors of the array are photon-noise limited under the radiative background of a 3.6 K black-body. This result, combined with the weak sensitivity to cosmic rays hits demonstrated with the OLIMPO flight, validates the idea of using lumped elements kinetic inductance detectors for precision, space-based CMB missions.

astro-ph.IM

High angular resolution Sunyaev Zel'dovich observations: the case of MISTRAL

The MIllimeter Sardinia radio Telescope Receiver based on Array of Lumped elements kids, MISTRAL, is a millimetric ($\simeq 90GHz$) multipixel camera being built for the Sardinia Radio Telescope. It is going to be a facility instrument and will sample the sky with 12 arcsec angular resolution, 4 arcmin field of view, through 408 Kinetic Inductance Detectors (KIDs). The construction and the beginning of commissioning is planned to be in 2022. MISTRAL will allow the scientific community to propose a wide variety of scientific cases including protoplanetary discs study, star forming regions, galaxies radial profiles, and high angular resolution measurements of the Sunyaev Zel'dovich (SZ) effect with the investigation of the morphology of galaxy cluster and the search for the Cosmic Web.

astro-ph.IM

The COSmic Monopole Observer (COSMO)

The COSmic Monopole Observer (COSMO) is an experiment to measure low-level spectral distortions in the isotropic component of the Cosmic Microwave Background (CMB). Deviations from a pure blackbody spectrum are expected at low level ($<$ 1 ppm) due to several astrophysical and cosmological phenomena, and promise to provide important independent information on the early and late phases of the universe. They have not been detected yet, due to the extreme accuracy required, the best upper limits being still those from the COBE-FIRAS mission. COSMO is based on a cryogenic differential Fourier Transform Spectrometer, measuring the spectral brightness difference between the sky and an accurate cryogenic blackbody. The first implementation of COSMO, funded by the Italian PRIN and PNRA programs, will operate from the Concordia station at Dome-C, in Antarctica, and will take advantage of a fast sky-dip technique to get rid of atmospheric emission and its fluctuations, separating them from the monopole component of the sky brightness. Here we describe the instrument design, its capabilities, the current status. We also discuss its subsequent implementation in a balloon-flight, which has been studied within the COSMOS program of the Italian Space Agency.

astro-ph.IM

N-nH complexes in GaAs studied at the atomic scale by cross-sectional scanning tunneling microscopy

Hydrogenation of nitrogen (N) doped GaAs allows for reversible tuning of the bandgap and the creation of site controlled quantum dots through the manipulation of N-nH complexes, N-nH complexes, wherein a nitrogen atom is surrounded by n hydrogen (H) atoms. Here we employ cross-sectional scanning tunneling microscopy (X-STM) to study these complexes in the GaAs (110) surface at the atomic scale. In addition to that we performed density functional theory (DFT) calculations to determine the atomic properties of the N-nH complexes. We argue that at or near the (110) GaAs surface two H atoms from N-nH complexes dissociate as an H$_2$ molecule. We observe multiple features related to the hydrogenation process, of which a subset is classified as N-1H complexes. These N-1H related features show an apparent reduction of the local density of states (LDOS), characteristic to N atoms in the GaAs (110) surface with an additional apparent localized enhancement of the LDOS located in one of three crystal directions. N-nH features can be manipulated with the STM tip. Showing in one case a switching behavior between two mirror-symmetric states and in another case a removal of the localized enhancement of the LDOS. The disappearance of the bright contrast is most likely a signature of the removal of an H atom from the N-nH complex.

cond-mat.mes-hall

In-flight performance of the LEKIDs of the OLIMPO experiment

We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the first hours of flight, we tuned the detectors and verified their large dynamics under the radiative background variations due to elevation increase of the telescope and to the insertion of the plug-in room-temperature differential Fourier transform spectrometer into the optical chain. We have found that the detector noise equivalent powers are close to be photon-noise limited and lower than those measured on the ground. Moreover, the data contamination due to primary cosmic rays hitting the arrays is less than 3% for all the pixels of all the arrays, and less than 1% for most of the pixels. These results can be considered the first step of KID technology validation in a representative space environment.

astro-ph.IM

Variation of the fundamental band gap nature in curved two-dimensional WS2

We report a strain-induced direct-to-indirect band gap transition in mechanically deformed WS2 monolayers (MLs). The necessary amount of strain is attained by proton irradiation of bulk WS2 and the ensuing formation of one-ML-thick, H2-filled domes. The electronic properties of the curved MLs are mapped by spatially- and time-resolved micro-photoluminescence revealing the mechanical stress conditions that trigger the variation of the band gap character. This general phenomenon, also observed in MoS2 and WSe2, further increases our understanding of the electronic structure of transition metal dichalcogenide MLs and holds a great relevance for their optoelectronic applications.

cond-mat.mtrl-sci

Phonon and light read out of a Li$_2$MoO$_4$ crystal with multiplexed kinetic inductance detectors

Molybdenum based crystals such as Li$_2$MoO$_4$ and CaMoO$_4$ are emerging as leading candidates for next generation experiments searching for neutrino-less double beta decay with cryogenic calorimeters (CUPID, AMoRE). The exquisite energy resolution and high radio-purity of these crystals come at the cost of a potentially detrimental background source: the two neutrinos double beta decay of $^{100}$Mo. Indeed, the fast half-life of this decay mode, combined with the slow response of cryogenic calorimeters, would result in pile-up events in the energy region of interest for neutrino-less double beta decay, reducing the experimental sensitivity. This background can be suppressed using fast and high sensitivity cryogenic light detectors, provided that the scintillation time constant itself does not limit the time resolution. We developed a new detection technique exploiting the high sensitivity, the fast time response and the multiplexing capability of Kinetic Inductance Detectors. We applied the proposed technique to a $2\times2\times2$ cm$^3$ Li$_2$MoO$_4$ crystal, which was chosen as baseline option for CUPID. We measured simultaneously both the phonon and scintillation signals with KIDs. We derived the scintillation time constant of this compound at millikelvin temperatures obtaining $τ_{scint} = 84.5\pm4.5\rm{(syst)}\pm1.0\rm{(stat)}$ $μ$s, constant between 10 and 190 mK.

physics.ins-det

Measurements and simulations of athermal phonon transmission from silicon absorbers to aluminium sensors

Phonon reflection and transmission at the interfaces plays a fundamental role in cryogenic particle detectors, in which the optimization of the phonon signal at the sensor (in case of phonon-mediated detectors) or the minimization of the heat transmission (when the detection occurs in the sensor itself) is of primary importance to improve sensitivity. Nevertheless, the mechanisms governing the phonon physics at the interfaces are still not completely understood. The two more successful models, the acoustic mismatch model (AMM) and diffuse mismatch model (DMM) are not able to explain all the accumulated experimental data and the measurement of the transmission coefficients between the materials remains a challenge. Here, we use measurements of the athermal phonon flux in aluminium Kinetic Inductance Detectors (KID) deposited on silicon substrates following a particle interaction to validate a Monte Carlo (MC) phonon simulation. We apply the Mattis-Bardeen theory to derive the phonon pulse energy and timing from the KID signal and compare the results with the MC for both AMM and DMM models, finding a remarkable good agreement for AMM, while diffuse reflection is clearly disfavored. For an aluminum film of 60 nm and a silicon substrate of 380~$μ$m, we obtain transmission coefficients Si-Al in the range [0.3-0.55] and Si-Teflon in the range [0.1-0.15].

physics.ins-det

Kinetic Inductance Detectors for the OLIMPO experiment: design and pre-flight characterization

We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460$\:$GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300$\:$mK. The measured average resonator $Q$s are 1.7$\times{10^4}$, 7.0$\times{10^4}$, 1.0$\times{10^4}$, and 1.0$\times{10^4}$ for the 150, 250, 350, and 460$\:$GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4$\:$rad/pW, 1.5$\:$rad/pW, 2.1$\:$rad/pW, and 2.1$\:$rad/pW; the electrical noise equivalent powers are 45$\:\rm{aW/\sqrt{Hz}}$, 160$\:\rm{aW/\sqrt{Hz}}$, 80$\:\rm{aW/\sqrt{Hz}}$, and 140$\:\rm{aW/\sqrt{Hz}}$, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NET$_{\rm RJ}$s are $200\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, and $\:340μ\rm{K\sqrt{s}}$, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.

astro-ph.IM

Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment

Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room--temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the $10^{4}-10^{5}$ range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a $cold$ $part$, which includes a low noise amplifier, a dc$-$block, coaxial cables, and power attenuators; and a $room-temperature$ $part$, FPGA$-$based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.

astro-ph.IM

Kinetic Inductance Detectors for the OLIMPO experiment: in--flight operation and performance

We report on the performance of lumped--elements Kinetic Inductance Detector (KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the detectors can be tuned in-flight, and their performance is robust against radiative background changes due to varying telescope elevation. We also find that the noise equivalent power of the detectors in flight is significantly reduced with respect to the one measured in the laboratory, and close to photon-noise limited performance. The effect of primary cosmic rays crossing the detector is found to be consistent with the expected ionization energy loss with phonon-mediated energy transfer from the ionization sites to the resonators. In the OLIMPO detector arrays, at float, cosmic ray events affect less than 4% of the detector samplings for all the pixels of all the arrays, and less than 1% of the samplings for most of the pixels. These results are also representative of what one can expect from primary cosmic rays in a satellite mission with similar KIDs and instrument environment.

astro-ph.IM